DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

G E L E L E L G5Q-EL/-EL2/-EL3 PCB Power Relay A Miniature Power Relay with high performance

  • IEC/EN 60335-1 conformed.
  • Coil insulation system: class F (UL1446)
  • [Type G5Q-EL] Higher performance compare with G5Q standard type. Minimum 100,000 operations durability at 10 A (250 VAC) switching.
  • [Type G5Q-EL2] High inrush capacity performance (Inrush current 40 A). UL508 TV3 conformed.
  • [Type G5Q-EL3] Ideal for motor switching 3 A with high inrush 30 A IEC/EN 60079-15 conformed. ■Model Number Legend ■Application Examples
  • Home appliances
  • Building automation
  • Lighting control
  • Output of control system
  • FA I/O module■Ordering Information Note 2. Contact your OMRON sales representative for tube packing models. ■Ratings
  • Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. Note 4. 5 VDC of coil rated voltage is available only for –EL3 RoHS Compliant 123 4 5 6 1. Number of Pole 1 : 1-pole 2. Contact Form A : SPST-NO (1a) 3. Enclosure rating None : Flux protection (-EL type only) 4 : Fully sealed (-EL2, -EL3) 4. Classification EL : For Resistive load EL2 : For Inrush load EL3 : For Motor load 5. Market Code HA : Home Appliance according to IEC/EN60335-1 6. Case Vent Hole None : No vent hole VH : Vent hole (-EL type only) Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit -EL type (For Resistive load) SPST-NO (1a) Flux protection (Vent hole type) G5Q-1A-EL-HA-VH

5 VDC

12 VDC

24 VDC

(For Inrush load) SPST-NO (1a) Sealed G5Q-1A4-EL2-HA -EL3 type (For Motor load) SPST-NO (1a) Sealed G5Q-1A4-EL3-HA Rated voltage Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)% of rated voltage 5 VDC 80.0 63 75% max. 5% min. 190% (at 23°C) Approx. 40012 VDC 33.3 360 24 VDC 16.7 1440 Note 1. When ordering, add the rated coil voltage to the model number. Example: G5Q-1A4-EL2-HA DC12 Rated coil voltage

G5Q-EL/-EL2/-EL3 PCB Power Relay G E L E L E L

  • Contacts ■Characteristics Note. Values in the above table are the initial values at 23°C. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resi stance was measured with a 500 VDC megohmmeter at the same locations as the electric strength was measured. *3. This value was measured at switching frequency of 120 operation/min. ■Engineering Data Load -EL type (For Resistive load) -EL2 type (For Inrush load) -EL3 type (For Motor load) SPST -NO (1a) Item Flux protection Sealed Sealed Contact type Single Contact material Ag-Alloy (Cd free) Rated load Resistive loadɿ 10 A at 250 VAC Capacitive loadɿ Inrush 40 A (100 μs) /

1 A break at 250 VAC

Motor load : Inrush 30 A (0.5 s) / 3 A break cosφ=0.5 at 250 VAC Rated carry current 10 A Max. rated voltage 277 VAC Max. rated current 10 A AC Item Classification -EL type (For Resistive load) -EL2 type (For Inrush load) -EL3 type (For Motor load) Contact resistance *1 100 mΩ max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 1,000 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Impulse withstand voltage Between coil and contacts 8 kV (1.2 x 50 μs) Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 100 m/s2 Durability Mechanical 10,000,000 operations (18,000 operations per hour) Electrical Resistive load 100,000 operations at 23°C (operation: ON for 1 sec. OFF for 9 sec.) Capacitive load 100,000 operations at 23°C (operation: ON for 1 sec. OFF for 3 sec.) Motor load 300,000 operations at 23°C (operation: ON for 1 sec. OFF for 1 sec.) Failure rate (P level) (reference *3) 10 mA at 5 VDC Ambient operating temperature -40°C to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 6.5 g

  • Maximum Switching Capacity (AC)
  • Ambient Temperature VS. Maximum Coil Voltage
  • Shock Malfunction 100 11 10 100 1000 Switching current (A) Switching voltgate (V) AC resistive load 200 180 160 140 120 100 0-40 20 23 0-20 80 60 10040 120 Maximum coil voltage (% of rated) Ambient temperature (°C) Note. The Maximum coil voltage refers to the maximum value in a varying of operating power voltage, not a continuous voltage. Energized De-energized Z X 1,000 1,000 1,000 1,0001,000 1,000 800 200 Z Shock direction Y XX ' Unit: m/s2 Sample: G5Q-1A-EL-HA-VH Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s

G5Q-EL/-EL2/-EL3 PCB Power Relay G E L E L E L ■Actual Load Life (Reference Values) G5Q-1A4-EL2-HA

120 VAC Capacitive load

Inrush: 56 A (0-P), Break: 0.2 A (rms) 200,000 operations min. (Ambient temperature: 23°C) ■Dimensions (Unit: mm) ■Approved Standards UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928) EN/IEC, VDE (Certified/No.40009467) ■Precautions

  • Please refer to “PCB Relays Common Precautions” for correct use. Model Coil ratings Contact ratings Number of test operations G5Q-1A-EL-HA-VH 5, 12, 24 VDC 10 A 250 VAC Resistive 40°C 6,000 G5Q-1A4-EL2-HA 5, 12, 24 VDC

5 A 250 VAC Resistive 85°C 6,000

TV-3 40°C 25,000 1 A 120 VAC 30 A Inrush-max. 1 msec 85°C 25,000 G5Q-1A4-EL3-HA 5, 12, 24 VDC

10 A 250 VAC Resistive 40°C 50,000

1/2HP 250 VAC 40°C 50,000 1/6HP 125 VAC 40°C 50,000 Model Coil ratings Contact ratings Number of test operations G5Q-1A-EL-HA-VH 5, 12, 24 VDC 10 A 250 VAC (cos φ=1) 105°C 10,000 G5Q-1A4-EL2-HA 5, 12, 24 VDC

5 A 250 VAC (cosφ=1) 85°C 10,000

Peak inrush 30 A / Break 1 A 230 VAC 85°C 25,000 G5Q-1A4-EL3-HA 5, 12, 24 VDC 3 A 250 VAC (cos φ=0.4) 85°C 50,000 Creepage distance 6.4 mm min. Clearance distance 5.5 mm min. Insulation material group IIIa Type of insulation coil-contact circuit open contact circuit Reinforced Micro disconnection Rated Insulation voltage 250 V Pollution degree 2 Rated voltage system 250 V Over voltage category III Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed) Glow wire according to IEC 60335-1 ed.5 GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) Tracking resistance according to IEC 60112 PTI 250 V min. (housing parts) Flammability class according to UL94 V-0 Coil Insulation system F Class (UL 1446) 7.62±0.1 Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm 15.8MAX (15.5)* 20.3MAX (20.0)* 0.4 3.4 7.6210.16 10.3MAX (10.0)* 7.62 (1.19) (1.18) 7.62±0.1 10.16±0.1 4-1.3 ±0.1 dia. 12 3 0.27 MAX (No coil polarity) * Average value 0.4 x 0.4 0.32 MAX G5Q-1A-EL-HA-VH G5Q-1A4-EL2-HA G5Q-1A4-EL3-HA

G5Q-EL/-EL2/-EL3 PCB Power Relay G E L E L E L  Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K284-E1-04 0118(0416)(O) Note: Do not use this document to operate the Unit.