G N B G5NB PCB Power Relay A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kV Impulse Withstand Voltage

  • Highly efficient magnetic circuit for high sensitivity (200 mW).
  • Standard model conforms to UL/CSA/VDE standards.
  • Satisfies EN61010 reinforced insulation requirements.
  • IEC/EN 60335-1 conformed. (-HA Model)
  • IEC/EN 60079-15 conformed. (Only for G5NB-1A4, G5NB-1A4-E Model)
  • Reduced power consumption with voltage holding and pulse width modulation (PWM) control (Only for G5NB-@-PW model) ■Model Number Legend ■Application Examples ■Ordering Information RoHS Compliant
  • Water heaters
  • Refrigerators
  • Air conditioners
  • Home appliances
  • Small electric appliances Terminal Shape Market Code Classification Contact form Enclosure rating Model Rated coil voltage Minimum packing unit PCB terminals General purpose Standard SPST-NO (1a) Flux protection G5NB-1A(-SP) 5VDC 12VDC 18VDC 24VDC 100 pcs/Tray (50 pcs/Tube) Sealed G5NB-1A4(-SP) Flux protection G5NB-1A-CF(-SP) 5VDC 12VDC 24VDC G5NB-1A-CF-PW(-SP) G5NB-1A-PW(-SP) High-capacity G5NB-1A-E(-SP) 5VDC 12VDC 18VDC 24VDCSealed G5NB-1A4-E(-SP) Home Appliance Standard Flux protection G5NB-1A-HA(-SP) 5VDC 12VDC 24VDC G5NB-1A-HA-CF(-SP) G5NB-1A-HA-CF-PW(-SP) G5NB-1A-HA-PW High-capacity G5NB-1A-E-HA(-SP) 12VDC 24VDC 1 2 345678 4. Classification None : Standard E : High-capacity 1. Number of Poles 1 : 1-pole 2. Contact Form A : SPST-NO (1a) 3. Enclosure rating None : Flux protection 4 : Sealed 5. Market Code None : General purpose HA : Home Appliance according to IEC/EN60335-1 6. Coil Insulation Class(UL1446) None : Class B CF : Class F 7. Special Requirement None : Not supported PW : Supported 8. Packing None : Tray Packing SP : Tube Packing Note 1. When ordering, add the rated coil voltage to the model number. Example: G5NB-1A DC5 However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@VDC. Note 2. When ordering tape packing, add "-SP" to the model number. Be sure since "-SP" is not part of the relay model number, it is not marked on the relay case. Rated coil voltage

G N B ■Ratings

  • Coil Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. * These numbers are only for -PW type. Power consumption with Holding Voltage is 32mW. Please confirm the detail in page 6 Coil Voltage Reduction (Holding Voltage).
  • Contacts ■Characteristics Note. Values in the above table are the initial values at 23°C. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. This value was measured at a switching frequency of 120 operations/min. ■Actual Load Life (Reference Values) 1. 120 VAC motor and lamp load 2.5A surge and 0.5A normal: 250,000 operations min. (at 23°C) 2. 160 VDC valve load (with varistor) 0.24A: 250,000 operations min. (at 23°C) 3. 140 VAC pump load Inrush: 5.4 A (o-p), Steady state: 1.6 A 200,000 operations min. (Ambient temperature: 23°C) 4. 100 VAC motor load Inrush: 10.7 A (o-p), Steady state: 1.1 A 200,000 operations min. (Ambient temperature: 23°C) Item Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)Rated voltage % of rated voltage

5 VDC 40 125

75% max. 10% min. 10 to 31%* Standard: 180% (at 23°C) High-capacity: 170% (at 23°C) Approx. 200 Approx. 32* 12 VDC 16.7 720 18 VDC 11.1 1,620 24 VDC 8.3 2,880 Item Load Resistive load Standard High-capacity Contact Type Single Contact material Ag-alloy (Cd free) Rated load 3 A at 125 VAC 5 A at 250 VAC

3 A at 30 VDC 3 A at 30 VDC

Rated carry current 3 A 5 A Max. switching voltage 250 VAC, 30 VDC Max. switching current 3 A 5 A Contact resistance *1 100 m Ω max. Operate time 10 ms max. Release time 10 ms max. Insulation resistance *2 1,000 M Ω min. Dielectric strength Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity

750 VAC, 50/60 Hz for 1 min

and contacts 10 kV (1.2 x 50 μs) Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s 2 Malfunction 100 m/s 2 Durability Mechanical 5,000,000 operations min. Electrical (resistive load) Standard (G5NB-1A, -1A4) 200,000 operations at 125 VAC, 3A 200,000 operations at 30 VDC, 3A High-capacity (G5NB-1A-E, -1A4-E) 100,000 operations at 250 VAC, 5A 200,000 operations at 30 VDC, 3A (with a rated load at 1,800 operations/hour) Failure rate (P level) (reference value) *3 DC5V 10mA Ambient operating temperature -40°C to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 4 g

G N B ■Engineering Data Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.

  • Maximum Switching Capacity Standard models High-capacity models
  • Durability Standard models High-capacity models
  • Ambient Temperature vs. Maximum Coil Voltage Standard models High-capacity models Switching voltage (V) 0.1 1 10 30 100 250 1,000 DC resistive load AC resistive load Switching current (A) Switching voltage (V) DC resistive load AC resistive load Switching current (A) 100 0 1 2 3 4

125 VAC, 30 VDC resistive load

Durability (10 operations) Switching current (A) 30VDC resistive load 250VAC resistive load Durability (x 10 4 operations) Switching current (A) Maximum coil voltage (%) Ambient temperature (°C) Test item: G5NB-1A, 24 VDC Number of Relays: 5 pcs 3A current Uncon- firmed area 40 60 80 85 100 120 140 160 200 220 100 180 0 20 23 220 200 180 160 140 120 100 0 20 23 40 60 80 85 100 Maximum coil voltage (%) Ambient temperature (°C) 5A current Uncon- firmed area Number of Relays: 5 pcs Test Item: G5NB-1A-E,24 VDC

G N B ■Dimensions (Unit: mm)

  • Shock malfunction Standard models High-capacity models Z Z Shock direction Unit: m/s 2 Y Y X X 1,000 1,000 1,000 1,000 1,000 1,000 Energized De-energized 700 125 Test Item: G5NB-1A, 24VDC Number of Relays: 5 pcs Test Method: Shock is applied 3 times in 6 directions along 3 axes and the level at which shock caused malfunction is measured. The energized voltage is 100% of the rated voltage. Rating: 100 m/s Z Z Shock direction Unit: m/s 2 Y Y X X 1,000 1,000 1,000 1,000 1,000 1,000 Energized De-energized 700 125 Test Item: G5NB-1A-E, 24VDC Number of Relays: 5 pcs Test Method: Shock is applied 3 times in 6 directions along 3 axes and the level at which shock caused malfunction is measured. The energized voltage is 100% of the rated voltage. Rating: 100 m/s 711.5 20.5max. (20.4)* 15.3max. (15.0)* 7.2max. (7.0)* 4.7 (1.05) (1.15) Four, 1.1 dia. 2 1 3.4 0.4 11.5 7 0.27 0.33 0.8 4.7 *Average value G5NB-1A(4)(-E)(-HA)(-CF)(-PW) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm (No coil polarity) Terminal Arrangement/ Internal Connections (Bottom View)

G N B ■Approved Standards The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use.

  • UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)
  • EN/IEC, VDE Certified (Certificate No. 137575) Model Contact form Coil ratings Contact ratings Number of test operations G5NB-1A(4)(-HA)(-CF)(-PW) SPST-NO (1a) 5 to 24V DC 3A 250V AC (Resistive) 85°C 100,000 3A 30V DC (Resistive) 70°C 6,000 G5NB-1A(4)-E G5NB-1A-E-HA 5A 250 V AC (Resistive) 85°C 5A 30 V DC (Resistive) 70°C 6,000 Model Contact form Coil ratings Contact ratings Number of test operations G5NB-1A(4)(-HA)(-CF)(-PW) SPST-NO (1a) 5, 12, 18, 24V DC 3A 250V AC (Resistive) 85°C 3A 30V DC (Resistive) 85°C 100,000 G5NB-1A(4)-E G5NB-1A-E-HA 5A 250 V AC (Resistive) 85°C 5A 30 V DC (Resistive) 85°C 10,000 3A 250V AC (Resistive) 85°C 100,000 Creepage distance 6.0 mm min. Clearance distance 6.0 mm min. Insulation material group IIIa Type of insulation coil-contact circuit open contact circuit Pollution degree 2 / Reinforced (Sealed) Pollution degree 3 / Basic (Flux protection) / Reinforced (Sealed) Micro disconnection Rated Insulation voltage 250 V Pollution degree 3 Rated voltage system 250 V Over voltage category III Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed) Glow wire according to IEC 60335-1 <HA Models only> GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) Tracking resistance according to IEC 60112 PTI 250 V min. (housing parts) Flammability class according to UL94 V-0

G N B ■Precautions

  • Please refer to “PCB Relays Common Precautions” for correct use.
  • Coil Voltage Reduction (Holding Voltage) after Relay Operation
  • If the coil voltage is reduced to the holding voltage after Relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below.
  • A voltage of at least 40% of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level. * The coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%.
  • Power consumption reduction of coil with pulse width modulation (PWM)
  • Models with PWM drive capability (-PW) can reduce coil holding current with PWM control. This function reduces power consumption by reducing the current held by coil.
  • Apply the rated voltage for at least 100 ms at the time of relay operation.
  • The following are our verification conditions. When using, it be sure to check the actual machine under the actual usage conditions. ■Example of drive circuit ■Conditions of validation carried out by OMRON Correct Use Applied coil voltage Coil resistance* Power consumption Rated voltage 100% 125Ω (5 VDC) 720Ω (12 VDC) 2880Ω (24 VDC) Approx. 200 mW Holding voltage 40% Approx. 32 mW 40% (Holding voltage) 100% (Rated voltage) 100ms min. Applied coil voltage (100%) Surge absorption diode Relay Coil Pulse input MOS-FET
  • Applied voltage: rated voltage
  • Duty: 50% or more
  • Frequency: 10 kHz or more
  • Diode Vf: 0.4 V or less Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Cat. No. J143-E1-17 0521(0207) Americas Europe Asia-Pacific China Korea Japan In the interest of product improvement, specifications are subject to change without notice. © OMRON Corporation 2007-2021 All Rights Reserved.