G5G OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Ideal for Microwave Oven Magnetrons and Heater Switching Conforms to IEC 255 (TÜV approval), UL508, CSA22.2. Slim relay with high switching power: 16 A. Dual #187 tab/PCB terminals. High impulse withstand voltage: 10 kV. RCE
Ordering Information
Enclosure ratings Contact form Standard Relays Flux protection SPST-NO G5G-1A Rated coil voltage Note: When ordering, add the rated coil voltage to the model number. Example: G5G-1A 12 VDC Model Number Legend G5G-jj jVDC 12 3 1. Number of Poles 1: 1 pole 2. Contact Form A: SPST-NO 3. Rated Coil Voltage 12, 18, 24 VDC Specifications Coil Ratings Rated voltage 12 VDC 18 VDC 24 VDC Rated current 41.7 mA 27.8 mA 20.8 mA Coil resistance 288 ! 648 ! 1,152 ! Must operate voltage 70% max. of rated voltage Must release voltage 5% min. of rated voltage Max. voltage 110% of rated voltage Power consumption Approx. 500 mW Contact Ratings Rated load 16 A at 250 VAC Rated carry current 16 A Max. switching power 4,000 VA
Contact resistance 100 m! max. Operate time 20 ms max. Release time 5m sm a x . Insulation resistance 1,000 M! min. (at 500 VDC) Dielectric strength 5,000 VAC between coil and contacts (1 min.) 1,000 VAC between contacts of same polarity (1 min.) Impulse withstand voltage 10,000 V (1.2× 50 "s) between coil and contacts Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction: 1,000 m/s2 Malfunction: 150 m/s2 Life expectancy Mechanical: 2,000,000 operations min. (18,000 operations/hr) Electrical: 100,000 operations min. (18,000 operations/hr) Ambient temperature Operating: - -40#Ct o7 0#C (with no icing) Storage: - -40 #Ct o7 0#C (with no icing) Ambient humidity 35% to 85% Weight Approx. 16 g Approved Standards UL508 (File No. E41515) Model Coil ratings Contact ratings Number of test operations G5G-1A 12 VDC
18 VDC
24 VDC
16 A, 250 VAC 6,000
CSA C22.2 (No. 14) (File No. LR31928) Model Coil ratings Contact ratings Number of test operations G5G-1A 12 VDC TÜV (IEC 255, File No. R9650783) Model Coil ratings Contact ratings Number of test operations G5G-1A 12 VDC
16 A, 250 VAC 100,000
250 VAC, 16 A (Rated Load) 1sO N / O F F ,a tr o o mt e m p . 100,000 220 VAC, 1.7 kW 3sO N / O F F ,a t8 0#C 380,000 120 VAC, 1.42 kW 3sO N / O F F ,a t8 0#C 500,000 121 VAC, 10.4 A 1 . 5sO N / O F F ,a t8 0#C 580,000 100 VAC, 12 A 1 . 5sO N / O F F ,a t8 0#C 200,000 100 VAC, 1.3 kW 3sO N / O F F ,a t8 0#C 290,000 Simulative Load Load Condition Operations 125 VAC, Inrush current 16.5 A Steady current 5.5 A 2 s ON (Inrush: 0.5 s /Steady: 1.5 s) 3 s OFF, at 45#C 250,000
Switching voltage (V) Switching current (A) AC resis- tive load Dimensions Three, 2 dia. 28 max. 23 max. 12.5 max. Two, #187 tab terminals Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Bottom View)5.6 6.35$0.15 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K110-E1-1