Subminiature Relay (16 x 9.9 x 8.4 mm (L x W x H)) with DPDT Contact ■ Unique moving-loop armature reduces relay size, magnetic interference and contact bounce time. ■ Miniature permissible load: 0.01 mA 10 mVDC. ■ Bifurcated gold-clad crossbar contact. ■ International 2.54-mm terminal pitch. ■ Special models available for FCC Part 68 compli- ance.

Ordering Information

■ Coil Ratings Single–side Stable Types Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 °C with a tolerance of ±10%. 2. Operating characteristics are meas ured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. RoHS Compliant Refer to pages 16 to 17 for details. RC FCC Classification Single-side stable Single-winding latching Double-winding latching DPDT Fully sealed G5A-234P G5AU-234P G5AK-234P Rated coil voltage Note: When ordering, add the rated coil voltage to the model number. Example: G5A-234P 12 VDC 1. Relay Function None: Single-side stable U: Single-winding latching K: Double-winding latching 2. Contact Form 2: DPDT 3. Contact Type 3: Bifurcated crossbar Ag (Au-Alloy) 4. Enclosure Ratings 4: Fully sealed 5. Terminals P: Straight PCB C: Self-clinching PCB 6. Special Function None: General-purpose FC: FCC part 68 compliance U: For ultrasonically cleanable 7. Rated Coil Voltage 3, 5, 6, 9, 12, 24, 48 VDC G5A - - VDC 1 2 3 45 6 7 Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω 8,230 Ω Coil inductance (H) (ref. value) Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 200% of rated voltage at 23°C 170% of rated volt- age at 23°C Power consumption Approx. 200 mW Approx. 280 mW

Single/Double–winding Latching Types Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 °C with a tolerance of ±10%. 2. Operating characteristics are meas ured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. ■ Contact Ratings Note: P level: λ60 = 0.1 x 10–6/operation This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual op- erating conditions. ■ Characteristics Note: The above values are initial values. Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. 2. Values in parentheses are actual values. 3. The insulation resistance was measured with a 250-VDC megohmmete r applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). 4. Models with FC suffix: 1,200 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 µs). 5. Models with FC suffix: 750 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 µs). Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC Coil resistance 45 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω Coil inductance (H) (ref. value) Must operate voltage 80% max. of rated voltage Must release voltage 80% min. of rated voltage Max. voltage 200% of rated voltage at 23°C Power consumption Approx. 200 mW Load Resistive load (cosφ = 1) Inductive load (cos φ = 0.4) (L/R = 7 ms) Rated load 0.5 A at 30 VAC; 1 A at 30 VDC 0.1 A at 30 VAC; 0.2 A at 30 VDC Contact material Ag (Au-Alloy) Rated carry current 1 A Max. switching voltage 125 VAC, 125 VDC Max. switching current 1 A 0.5 A Max. switching power 37.5 VA, 33 W 12.5 VA, 11 W Failure rate (reference value) (See note.) 0.01 mA at 10 mVDC Contact resistance (See note 1.) 50 mΩ max. Operate (set) time (See note 2.) Single-side stable types: 5 ms max. (approx. 2.4 ms) Latching types: 5 ms max. (approx. 2 ms) Release (reset) time (See note 2.) Single-side stable types: 5 ms max. (approx. 1.1 ms) Latching types: 5 ms max. (approx. 1.8 ms) Min. set/reset signal width Latching type: 7 ms Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance (See note 3.) 1,000 MΩ min. (at 250 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts (See note 4.) 1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity (See note 4.) 500 VAC, 50/60 Hz for 1 min between contacts of same polarity (See note 5.)

100 VAC, 50/60 Hz for 1 min between set and reset coils (double-winding type only)

Impulse withstand voltage 1,500 V (10 x 160 µs) between contacts of same polarity (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 300 m/s2 (approx. 30G) Endurance Mechanical: 50,000,000 operations min. (at 36,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) Ambient temperature Operating: −40°C to 70°C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 3 g

■ Approved Standards Model Contact form Coil ratings Contact ratings G5A-234P DPDT 3 to 48 VDC 0.5 A, 60 VAC

0.5 A, 60 VDC

1 A, 30 VDCG5AU-234P

Maximum Switching Power Ambient Temperature vs. Maximum Coil Voltage Endurance Switching current (A) Switching voltage (V) Switching current (A) Endurance (x10 operations)3 Ambient temperature (°) Maximum coil voltage (%) DC resistive load AC resistive load DC inductive load (L/R = 7 ms) 30-VDC resistive load 30-VAC resistive load 30-VAC inductive load (cosf = 0.4) 200/150 mW 280 mW 30-VDC inductiveload (L/R = 7 ms) AC inductive load (cosf = 0.4) 10,000 5,000 1,000 500 100 Note: The maximum coil voltage refers to the maxi-mum value in a varying range of operating power voltage, not a continuous voltage.

Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Precautions Long-term Continuously ON Contacts Using the Relay in a circuit where the Relay will be ON continu- ously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. Relay Handling When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40 °C. Do not put the Relay in a cold cleaning bath immediately after soldering. G5A-234P Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 G5AU-234P G5AK-234P S: Set coil R: Reset coil 16 max. (15.9)* 9.9 max. (9.8)* 0.6 0.25 7.62 0.648.4 max. (8.3)* 3.16 0.648.4 max. (8.3)* 3.16 16 max. (15.9)* 9.9 max. (9.8)* 0.6 0.25 7.62 16 max. (15.9)* 9.9 max. (9.8)* 8.4 max. (8.3)* 0.64 3.16 0.6 0.25 7.62 *Average value S R SR 5.08 5.08 2.54 (1.2) 7.62 (2) (1.1) Eight, 1-dia. holes 5.08 5.08 2.54 (1.2) 7.62 (2) (1.1) Eight, 1-dia. holes 2.54 5.08 2.54 (1.2) 7.62 (2) (1.1) Ten, 1-dia. holes 2.54 *Average value *Average value ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K019-E1-05