Slimmest OMRON plug-in SSR with maximum width 6.2 mm
- Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage resistive loads of 100 µA to 3.0 A LED indicator for visible operation checking Convenient quick electrical connections possible with G3RV push-in models and cross bar connectors Low power consumption for energy savings G3RV is cUL listed when correct relay is matched with the G3RV Socket Model Number Structure ■Model Number Legend 1. Basic Model Name G3RV: Solid State Relay 2. Auxiliary Type Designation SL: Slim Solid State Relay and socket combination 3. Wire Connection 700: Screw Terminals 500: Push-in (screwless) terminals 4. Output voltage specifications A(L): AC Output .. TRIAC *A: with Zero cross function AL: without Zero cross function D: DC Output .. MOS FET
Ordering Information
■List of Models SSR and Socket Combinations 123 4 G3RV-SL @ @ @ - @ Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug-in terminals General-purpose Unseal ed AC/DC Screw terminals G3RV-SL700 Push-in terminals G3RV-SL500 Input voltage Screw terminals Push-in terminals
12 VDC G3RV-SL700-D 12VDC G3RV-SL500-D 12VDC
G3RV-SL700-A(L) 12VDC G3RV-SL500-A(L) 12VDC
24 VDC G3RV-SL700-D 24VDC G3RV-SL500-D 24VDC
G3RV-SL700-A(L) 24VDC G3RV-SL500-A(L) 24VDC
24 VAC/DC G3RV-SL700-D 24VAC/DC G3RV-SL500-D 24VAC/DC
G3RV-SL700-A(L) 24VAC/DC G3RV-SL500-A(L) 24VAC/DC
48 VAC/DC G3RV-SL700-D 48VAC/DC G3RV-SL500-D 48VAC/DC
G3RV-SL700-A(L) 48VAC/DC G3RV-SL500-A(L) 48VAC/DC
110 VAC G3RV-SL700-D 110VAC G3RV-SL500-D 110VAC
G3RV-SL700-A(L) 110VAC G3RV-SL500-A(L) 110VAC
230 VAC G3RV-SL700-D 230VAC G3RV-SL500-D 230VAC
G3RV-SL700-A(L) 230VAC G3RV-SL500-A(L) 230VAC
2 Solid State Relays G3RV
■Ratings (at an Ambient Temperature of 25°C) Input G3RV-SL700/500-A Series G3RV-SL700/500-AL Series G3RV-SL700/500-D Series Output Rated voltage Rated current Must operate voltage Must release voltage Input voltage AC DC % of rated voltage
50 Hz 60 Hz
24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V Rated voltage Rated current Must operate voltage Must release voltage Input voltage AC DC % of rated voltage 24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V Rated voltage Rated current Must operate voltage Must release voltage Input voltage AC DC % of rated voltage 24 VAC/DC 10.7 mA 11.1 mA 4.3 mA 21.6V 48 VAC/DC 9.6 mA 10.2 mA 6 mA 43.2V 110 VAC 6.8 mA 7.5 mA --- 99V 230 VAC 6.8 mA 8.1 mA --- 207V Item G3RV-SL700/500-A(L) G3RV-SL700/500-D Rated load voltage AC100~240V (50/60Hz) DC5~24V Load voltage range AC75~264V (50/60Hz) DC3~26.4V Load current 0.1~2A (Ta=40°C) 100µA~3A (Ta=40°C) Inrush current 30A (60Hz/1cycle) 30A (60Hz/1cycle) Permissible I2t ; Joule Integral (Reference value) 15A2s9 A2s Application load capacity 400W (Output voltage: AC200V) 72W (Output voltage: DC24V)
■Characteristics ■Approved Standards UL 508 (File No. E64562) IEC/TUV (EN 62314) Item G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. 6 ms max. Release time 40 ms max. 20 ms max. 60 ms max. Output ON voltage drop 1.6 V rms max. 0.9 V max. Leakage current 5 mA max. (at 200 VAC 50/60Hz) 10 µA max. (at 24VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength AC2500V 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude Shock resistance 300m/s2 Ambient temperature Storage: -30~+100°C (with no icing or condensation) Operating: -30~+55°C (with no icing or condensation) Ambient humidity 45~85%RH Weight Approx. 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Withstand Voltage 4.0kV / III Load category LC-A DC-12 Overload Current Profile 1.5Ie 1.1Ue 5s ON, 10s OFF , 10cycles Rated insulation Voltage 240V Model Input ratings Contact ratings G3RV-SL700/500-D Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC
24 VDC 3 A (Resistive Load) at 25°C
G3RV-SL700/500-A(L) Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC
240 VAC 2 A (Resistive Load) at 25°C
Input ratings Contact ratings 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC
24 VDC 3 A (Resistive Load)
12, 24 VDC 24, 48 VAC/DC 110, 230 VAC
240 VAC 2 A (Resistive Load)
4 Solid State Relays G3RV
■Load current derating curves G3RV-SL700/500-A(L) Series G3RV-SL700/500-D Series ■One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents. Mounting Distance 10mm Mounting Distance 0mm Mounting Distance 10mm Mounting Distance 0mm G3RV-SL700/500-A(L) Series G3RV-SL700/500-D Series 㪇 㪌 㪈㪇 㪈㪌 㪉㪇 㪉㪌 㪊㪇 㪊㪌 㪈㪇 㪈㪇㪇 㪈㪇㪇㪇 㪜㫅㪼㫉㪾㫀㫑㪼㪻㩷㫋㫀㫄㪼㩷㩿㫄㫊㪀 㪠㫅㫉㫌㫊㪿㩷㪺㫌㫉㫉㪼㫅㫋㩷㩿㪘㪅㩷㪧㪼㪸㫂㪀
■PLC Interface (for G2RV-SL700 & G3RV-SL700 series only) List of Models Specifications Electrical schematic P2RVC-O-8-F Model number Description Connection P2RVC-8-O-F PLC Output Interface for 8x G2RV-SL700 & G3RV-SL700 series PNP - type Ribbon cable connector
10 Pole, IEC603/1
Input Rated voltage 30 VAC/VDC max. Current capacity 0.5 A per channel
2.0 A total current, power supply terminal
Characteristics Ambient temperature Operating: 0 to 55°C Storage: − 20 to 85°C Overvoltage category III Pollution degree 2
6 Solid State Relays G3RV
■SSR for Maintenance (Replacement SSRs) Model Number Legend 1. Output voltage specifications D: DC Output 2: AC Output 2. Rated Current 02: AC Output 2A 03: DC Output 3A 3. Terminals S: Plug-In 4. Zero cross function Blank: with Zero cross function L : without Zero cross function List of Models *different by ambient temperature. Please refer to 4 pages of characteristic data “ ■ Load current derating curves” for the details. 12 3 4 G3RV-@ @ @ @ Isolation Movement indication Rated input voltage (Socket) Output (SSR) Zero cross function Rated output load* Model Number Replacement for Phototriac Y es (Green) DC12V AC Y es 2A at 100 to 240VAC G3RV-202S DC12 G3RV-SL700/500-A DC12 DC24V G3RV-202S DC24 G3RV-SL700/500-A DC24 AC/DC24V G3RV-SL700/500-A AC/DC24 AC/DC48V G3RV-SL700/500-A AC/DC48 AC110V G3RV-202S DC48 G3RV-SL700/500-A AC110 AC230V G3RV-SL700/500-A AC230 DC12V No G3RV-202SL DC12 G3RV-SL700/500-AL DC12 DC24V G3RV-202SL DC24 G3RV-SL700/500-AL DC12 AC/DC24V G3RV-SL700/500-AL AC/DC24 AC/DC48V G3RV-SL700/500-AL AC/DC48 AC110V G3RV-202SL DC48 G3RV-SL700/500-AL AC110 AC230V G3RV-SL700/500-AL AC230 Photocoupler DC12V DC --- 3A at 5 to
24 VDC
G3RV-D03SL DC12 G3RV-SL700/500-D DC12 DC24V G3RV-D03SL DC24 G3RV-SL700/500-D DC24 AC/DC24V G3RV-SL700/500-D AC/DC24 AC/DC48V G3RV-D03SL DC48 G3RV-SL700/500-D AC/DC48 AC110V G3RV-SL700/500-D AC110 AC230V G3RV-SL700/500-D AC230
■Cross bars Model Number Legend 1. Number of Poles 2. Color 020: 2 poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black 100: 10 poles 200: 20 poles List of Models @ select color: R = Red, S = Blue, B = Black Specification ■Plastic Labels for G2RV/G3RV Sockets ■Labels (Stickers) for G2RV/G3RV Sockets Model number Poles Quantity Color P2RVM-020@ 2 60 pcs / box (minimum order) Red (R) Blue (S) Black (B) P2RVM-030@ 3 60 pcs / box (minimum order) P2RVM-040@ 4 60 pcs / box (minimum order) P2RVM-100@ 10 20 pcs / box (minimum order) P2RVM-200@ 20 20 pcs / box (minimum order) Max current (EN60947-7-1 section 8.3.3 / 1991) 32A Max. Voltage 400 VAC Max. Voltage when cutting Cross-bar without using separation plate or end-bracket
250 VAC
P2RVM -@ @ Model number Box quantity Color R99-15 for G2RV 5 sheets × 120 labels = 600 labels (minimum order) White Model number Box quantity Color R99-16 for G2RV 10 sheets × 484 labels = 4,840 labels (minimum order) White
8 Solid State Relays G3RV
■Separating Plates Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit G3RV-SL700 Model number Quantity Description P2RV-S 50 plates Provides isolation between adjacent relays to achieve 400 V isolation. Five, M2.5 × 6 6.2 max. 99.2 7.188.9 26.1 47.2 70.9 106.7 max. 92.7 max. Input circuit
24 V DC
(Top View) Other Input Voltage Terminal Arrangement/ Internal Connections (Top View)
12 V DC
(Top View)
(Top View) Other Input Voltage Terminal Arrangement/ Internal Connections (Top View) (Top View) 6.2 max. 99.2 88.9 7.1 24.6 69.8 82.9 106.7 max. 97.4 max.35 G3RV-D03SL G3RV-202S(L) Input circuit G3RV-D03SL G3RV-202S(L) PD[ PD[ PD[ Terminal Arrangement/ Internal Connections (Bottom View)
10 Solid State Relays G3RV
■Tools G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver
- Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) Examples: FACOM AEF .2.5 × 75E (AEF . 3 × 75E) WAGO 210-119 WIHA 260/2.5 × 40 (260/3 × 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. ■Applicable Wires Applicable Wire Sizes G3RV-SL700 Series Box clamp technology G3RV-SL500 Series Push-in technology Tightening torque G3RV-SL700 Series: 0.4Nm 2.5 dia. (3.0 mm max.) Cannot be used.
- Flat-blade, Flared-tip
- Flat-blade, Parallel-tip Wire type Applicable wire size Stripping length Stranded without ferrules 0.5 - 1.5 mm2 7m m Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 7m m Stranded with ferrules without plastic collar 0.5 - 1.5 mm2 7m m Solid 0.5 - 1.5 mm2 7m m Wire type Applicable wire size Stripping length Stranded without ferrules 0.5 - 1.5 mm2 12 mm Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 12 mm Stranded with ferrules without plastic collar 0.5 - 1.5 mm2 12 mm Solid 0.5 - 1.5 mm2 12 mm
Solid State Relays G3RV 11 ■Wiring Use wires of the applicable sizes specified above. The lengt h of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series. Wiring Procedure for G3RV-SL500 series
- Wiring Insert the exposed conductor into the connection hole. No other tools are required. Note: In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire.
- Removing Insert the specified screwdriver into the release hole. Removing wire. Removing screwdriver. 7 mm Fig. 1 Exposed Conductor Length 12 mm G3RV-SL700 G3RV-SL500 Screwdriver hole Wire connection hole Wire
12 Solid State Relays G3RV
Precautions for Connection Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. Insert the screwdriver along the hole wall as shown below. If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. General Precautions Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. Do not pour water or cleansing agents on the product. Doing so may result in electric shock. Do not use the socket in locations subject to solvents or alkaline chemicals. Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. Do not dispose the product in fire. Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. Screwdriver
Solid State Relays G3RV 13 Definition of Precautionary Information Precautions for Safe Use
- Shipping When shipping the G3RV, be sure to avoid the following: Conditions where the G3RV is exposed to water. High ambient temperatures and humidity. Inadequate packaging Failure to avoid these conditions while shipping G3RV will lead to damage, malfunction, or deterioration.
- Operating and Storage Locations Do not use or store the G3RV in the locations listed below. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics. Locations subject to rain or water drops. Locations subject to exposure to water, or oil, or chemicals. Locations subject to high temperatures or high humidity. Locations subject to ambient temperatures outside the range from -30 to +100 centigrade. Locations subject to relative humidity outside the range 45% to 85%. Locations subject to corrosive or flammable gases. Locations subject to dust (especially iron dust) or salts. Locations subject to barrier. Locations subject to static electricity or other forms of noise. Locations subject to strong electromagnetic fields. Locations subject to possible exposure to radioactivity.
- Handling Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and burning. Do not install G3RV Relay with bent terminals into the socket. Doing so could lead to poor electrical connection and hazardous conditions. Be sure to mount G3RV's with clean hands. Performing mounting with oil stained hands or coated with metal powder could result in hazardous outcomes.
- Mounting Be sure to mount the G3RV in the specified orientation. Mounting the G3RV in a different orientation could lead to abnormal heat generation causing output elements to short leading to burning. G3RV's are SSR's and generate heat. Be sure to control ambient temperature in setting where G3RV is used. If mounted in an enclosed space, install a fan to insure G3RV is properly ventilated. Be sure that the G3RV clicks into place when mounting it to DIN Track. The G3RV may fall if it is not mounted correctly.
- Wiring Use a wire an adequate size for current to be applied. Abnormal heating of wire may cause burning. Do not use any wires with damaged sheaths. These may cause electric shock. Confirm that wiring to G3RV Socket is not used in pipe or duct for high voltage power supply. Using a wire in pipe or duct connected to high voltage power supply will generate induction causing malfunction or damage. Be sure to conduct wiring with the power supply turned OFF . Touching the terminals when they are charged may occasionally result in minor electric shock.
- Using Select a load within the rated range. Inappropriate load may cause misoperation, trouble or burning. Select the power supply within the rated frequency range. Inappropriate power frequency may cause misoperation, trouble or burning. Precautions for Correct Use
- G3RV uses electronics parts inside, so that any dropping, vibration, and physical shock beyond the standard level should be prevented. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics.
- Be sure to use tightening torque of 0.4 N·m for screw terminal G3RV. Failure to do so could result in short circuit failure and burning.
- Be sure to use proper voltage/current to G3RV input and output terminals. Failure to do so could result in short circuit failure and burning. WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. CAUTION A potentially hazardous situation by misuse, may result in property damage only accident. CAUTION Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's terminal (Charging part) while the power supply turned on. The G3RV may occasionally rupture in case of a short circuit. To protect against short-circuit accident, install a protective device, such as a quick-burning fuse or a circuit breaker or the like, on the power supply. Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's main circuit terminals immediately after the power is turned OFF . The internal snubber circuit is charged. * 202S,SL,G3RV-A(L) Type only Minor hazard by burns may occasionally occur. Do not touch the G3RV or the heat sink either while the power supply is ON, or immediately after the power is turned OFF . The G3RV and the heat sink will be hot.
14 Solid State Relays G3RV
- Mounting <SSR Mounting Pitch (Panel Mounting)> <Relations between SSR and duct (Depth of duct)> <Ventilation Outside the Control Panel> * If the air inlet or outlet has a filter, clean the filter regularly to prevent it from clogging and ensuring efficient flow of air. * Do no locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. * A heat exchanger, if used, should be located in front of the G2RVs to ensure the efficiency of the heat exchanger. * Please monitor the ambient temperature of the G3RV's. The rated load current is measured at 25°C ambient temperature. * A G3RV uses semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To the restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the G3RVs and thus increase reliability. (Generally, each 10°C reduction in temperature will double the expected life.)
- EMI This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. Suitability for Use OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERL Y RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. See also Product catalog for Warranty and Limitation of Liability. Duct 60mm min. 80mm min. 30mm min. SSR Vertical direction Counter measure(1)Duct Depth Counter measure(2) Duct or air flow obstruction The depth of SSR SSR SSR SSR Vertical direction Duct or air flow obstruction Duct or air flow obstruction Duct or air flow obstruction The recommended width is 1/2 as large as the depth of SSR or less Duct or air flow obstruction Air flow Duct or air flow obstruction Do not surrounded the SSR with the duct in the depth direction, or otherwise the heat radiation of the S5R will be adversely affected. If the height of the ducts can not be lowered, place the SSR or a metal base so that they are not surrounded by the ducts. Use a short duct in the depth direction. Metal base SSR SSR SSR Air inlet Be aware of air flow Duct Ventllation outlet In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J180-E2-02