DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
G R G R D G3R/G3RD Solid State Relays Same Shape as SSR Type G2R Power Relay for PCB Mounting
- Direct mounting to PCBs. Also standardized with input indicator.
- High dielectric strength of 2,500 VAC for 2-A models.
- High-voltage DC version also available.
- Lineup includes models with UL and CSA certification (model numbers ending in “-US”). ■List of Models ■Ratings Input (AC Output With Zero Cross Function) Input (AC Output Without Zero Cross Function, DC Output) Output ■Characteristics RoHS Compliant Refer to "Solid State Relays Common Precautions". Terminals Isolation Zero cross function Indicator Rated output load Rated input voltage Model Minimum packing unit PCB Phototriac Yes Yes
2 A at 100 to 120 VAC *1
5, 12, 24 VDC G3R-102PN 20 pcs No G3R-102PLN Yes 2 A at 100 to 240 VAC *2 G3R-202PN No G3R-202PLN Photocoupler − 1.5 A at 5 to 110 VDC G3RD-101PN
2 A at 4 to 48 VDC *3 G3RD-X02PN
Model Item Rated voltage Operating voltage Must operate voltage level Must release voltage level Input impedance G3R-102PN G3R-202PN 5 VDC 4 to 6 VDC 3.5 VDC max. 0.375 VDC min. 250 Ω±20% Model Item Rated voltage Operating voltage Must operate voltage level Must release voltage level Input impedance G3R-102PLN G3R-202PLN G3RD-X02PN G3RD-101PN 5 VDC 4 to 6 VDC 3.5 VDC max. 0.375 VDC min. 300 Ω±20% Item Applicable load Model Rated load voltage Load voltage range Load current Inrush current G3R-102PN G3R-102PLN 100 to 120 VAC 75 to 132 VAC 0.1 to 2 A *
30 A (60 Hz, 1 cycle)G3R-202PN
G3R-202PLN 100 to 240 VAC 75 to 264 VAC 0.1 to 2 A * G3RD-X02PN 4 to 48 VDC 3 to 52.8 VDC 0.01 to 2 A * 8 A (10 ms) G3RD-101PN 5 to 110 VDC 3 to 125 VDC 0.01 to 1.5 A * 2.5 A (10 ms) Model Item G3R-102PLN G3R-102PN G3R-202PLN G3R-202PN G3RD-X02PN G3RD-101PN Operate time 1 ms max. 1/2 of load power source cycle + 1 ms max. 1 ms max. 1/2 of load power source cycle + 1 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.5 V max. Leakage current 2 mA max. (at 100 VAC) 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 0.1 mA max. (at 50 VDC) 0.1 mA max. (at 125 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60Hz for 1 min. between input and output Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance 1,000 m/s Ambient operating temperature –30°C to 80°C (with no icing or condensation) Ambient operating humidity 45% to 85%RH Storage temperature –30°C to 100°C (with no icing or condensation) Weight Approx. 12g (1-A load model), Approx. 18 g (2-A LOAD, DC output model) * The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data.
G3R/G3RD Solid State Relays G R G R D ■Engineering Data
- Load Current vs. Ambient Temperature Characteristics ■Dimensions (Unit: mm) ■Safety Precautions
- Please refer to “Solid State Relays Common Precautions” for correct use. 1-A Load Model G3RD-101PN 2-A Load Model G3R-102P(L)N, G3RD-X02PN, G3R-202P(L)N
- One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3R-102PN, G3R-102PLN G3R-202PN, G3R-202PLN G3RD-101PN For DC-load G3RD-X02PN 1.5 0.5 −30 −20 0 20 40 60 80 100 Ambient temperature (°C) Load current (A) 1.5 0.5 −30 −20 0 20 40 60 80 100 Ambient temperature (°C) Load current (A) 0 10 30 50 100 300 500 1,000ɹ 3,000 Energized time (ms) Inrush current (A. Peak) 0 10 30 50 100 300 500 1,000 3,000 Energized time (ms) Inrush current (A. Peak) 10 30 50 100 300 500 1,000 ࠉࠉ3,000 Energized time (ms) Inrush current (A) 29 max. 13 max. 29 max. (0.3) 4 2-1 3.5 2-0.5 20.0 7.5 2-0.5 7.5 (2.1) 20 3.5 Four 1.3-dia. holes Input voltage Load power supply Load LOADINPUT + 5 (+) (−) (+) (−) G3R-102P@ G3R-202P@ G3RD-101PN G3RD-X02PN Mounting Holes (BOTTOM VIEW) Terminal Arrangement/ Internal Connections (BOTTOM VIEW) Note. The plus and minus symbols shown in the parentheses are for DC loads.
G3R/G3RD Solid State Relays G R G R D Cat. No. K059-E1-08 0117(0207)(O) Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the man ual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or eq uipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the prod uct provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Note: Do not use this document to operate the Unit.