Solid State Contactors (Three-phase) G3PB-2/-3 Compact, Low-cost Solid State Contactors of an Innovative Construction Ideal for Three-phase Heaters
- Slim Units with three-phase output. Optimum heat sinks attach to models without built-in heat sinks. Compact design achieved by optimizing heat sink shape. DIN track mounting possible (when using the Y92B-P50 Heat Sink) in addition to screw mounting. Comply with EN60947-4-3 (IEC947-4-3) UL508, and CSA22.2 No. 14, and bear CE marking. Refer to Safety Precautions for All Solid State Relays. Model Number Structure ■Model Number Legend 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 4: 400 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase 2: 3-phase, 2-element models 3: 3-phase, 3-element models 6. 3-phase Type Blank: Built-in heat sink H: No heat sink (“hockey puck” type) 7. Certification VD: Certified by UL, CSA, and VDE 1 23 4 56 7
Ordering Information
■List of Models Models with Built-in Heat Sinks Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 2. When ordering, specify the rated input voltage. Models without Built-in Heat Sinks Note: 1. The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 2. When ordering, specify the rated input voltage. Heat Sinks ■Accessories (Order Separately) Number of phases Main circuit voltage Zero cross function Applicable load current (with Class-1 AC resistive load) Number of elements Model 3 100 to 240 VAC Y es 15 A max. 3 G3PB-215B-3-VD
2 G3PB-215B-2-VD
25 A max. 3 G3PB-225B-3-VD
2 G3PB-225B-2-VD
35 A max. 3 G3PB-235B-3-VD
2 G3PB-235B-2-VD
45 A max. 3 G3PB-245B-3-VD
2 G3PB-245B-2-VD
200 to 400 VAC 15 A max. 3 G3PB-415B-3-VD
2 G3PB-415B-2-VD
25 A max. 3 G3PB-425B-3-VD
2 G3PB-425B-2-VD
35 A max. 3 G3PB-435B-3-VD
2 G3PB-435B-2-VD
45 A max. 3 G3PB-445B-3-VD
2 G3PB-445B-2-VD
Main circuit voltage Zero cross function Applicable load current Number of elements Model 3 100 to 240 VAC Y es 15 A max. 3 G3PB-215B-3H-VD
2 G3PB-215B-2H-VD
25 A max. 3 G3PB-225B-3H-VD
2 G3PB-225B-2H-VD
35 A max. 3 G3PB-235B-3H-VD
2 G3PB-235B-2H-VD
45 A max. 3 G3PB-245B-3H-VD
2 G3PB-245B-2H-VD
200 to 400 VAC 15 A max. 3 G3PB-415B-3H-VD
2 G3PB-415B-2H-VD
25 A max. 3 G3PB-425B-3H-VD
2 G3PB-425B-2H-VD
35 A max. 3 G3PB-435B-3H-VD
2 G3PB-435B-2H-VD
45 A max. 3 G3PB-445B-3H-VD
2 G3PB-445B-2H-VD
Heat resistance (°C/W) Model
1.67 Y92B-P50
1.01 Y92B-P100
0.63 Y92B-P150
0.43 Y92B-P200
0.36 Y92B-P250
Mounting Track 50 cm (1) x 7.3 mm (t) PFP-50N 1 m (1) x 7.3 mm (t) PFP-100N 1 m (1) x 16 mm (t) PFP-100N2
■Ratings (at an Ambient Temperature of 25°C) Operating Circuit (Common) Main Circuit of Models with Built-in Heat Sinks Note: The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. Item Common Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current 10 mA max. (at 24 VDC) Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Insulation method Phototriac Operation indicator Ye l l ow L E D Item G3PB- 215B-3-VD G3PB- 215B-2-VD G3PB- 225B-3-VD G3PB- 225B-2-VD G3PB- 235B-3-VD G3PB- 235B-2-VD G3PB- 245B-3-VD G3PB- 245B-2-VD Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Applicable load current (See note.) 0.2 to 15 A at 40°C 0.2 to 25 A at 40°C 0.5 to 35 A at 25°C 0.5 to 45 A at 25°C Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave)
121 A2s2 6 0 A 2s 1260 A 2s
(with Class-1 AC resistive load) 5.1 kW max. (at 200 VAC) 8.6 kW (at 200 VAC) 12.1 kW max. (at 200 VAC) 15.5 kW max. (at 200 VAC) Item G3PB- 415B-3-VD G3PB- 415B-2-VD G3PB- 425B-3-VD G3PB- 425B-2-VD G3PB- 435B-3-VD G3PB- 435B-2-VD G3PB- 445B-3-VD G3PB- 445B-2-VD Rated load voltage 200 to 400 VAC Load voltage range 180 to 440 VAC Applicable load current (See note.) 0.5 to 15 A at 40°C 0.5 to 25 A at 40°C 0.5 to 35 A at 25°C 0.5 to 45 A at 25°C Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I (half 60-Hz wave)
260 A2s2 6 0 A 2s 1260 A 2s
(with Class-1 AC resistive load) 10.3 kW max. (at 400 VAC) 17.3 kW max. (at 400 VAC) 24.2 kW max. (at 400 VAC) 31.1 kW max. (at 400 VAC)
Main Circuit of Models without Built-in Heat Sinks Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. Item G3PB-215B- 3H-VD G3PB-215B- 2H-VD G3PB-225B- 3H-VD G3PB-225B- 2H-VD G3PB-235B- 3H-VD G3PB-235B- 2H-VD G3PB-245B- 3H-VD G3PB-245B- 2H-VD Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Applicable load current (See note.) 0.2 to 15 A at 40°C 0.2 to 25 A at 40°C 0.2 to 35 A at 25°C 0.2 to 45 A at 25°C Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave)
121 A2s 260 A 2s 1260 A 2s
(with Class-1 AC resistive load) The applicable load varies with the heat radiation of the Unit. Refer to page 7, Engineering Data for details. Item G3PB-415B- 3H-VD G3PB-415B- 2H-VD G3PB-425B- 3H-VD G3PB-425B- 2H-VD G3PB-435B- 3H-VD G3PB-435B- 2H-VD G3PB-445B- 3H-VD G3PB-445B- 2H-VD Rated load voltage 200 to 400 VAC Load voltage range 180 to 440 VAC Applicable load current (See note.) 0.5 to 15 A at 40°C 0.5 to 25 A at 40°C 0.5 to 35 A at 25°C 0.5 to 45 A at 25°C Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I (half 60-Hz wave)
260 A2s 260 A 2s 1260 A 2s
(with Class-1 AC resistive load) Refer to page 7, Engineering Data for details.
■Characteristics Models with Built-in Heat Sinks Note: The leakage current of phase S will be approximately times larger if the 2-element model is applied. Note: The leakage current of phase S will be approximately times larger if the 2-element model is applied. Item G3PB- 215B-3-VD G3PB- 215B-2-VD G3PB- 225B-3-VD G3PB- 225B-2-VD G3PB- 235B-3-VD G3PB- 235B-2-VD G3PB- 245B-3-VD G3PB- 245B-2-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.6 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: –30 °C to 80°C (with no icing or condensation) Storage: –30 °C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Weight Approx. 750 g Approx. 750 g Approx. 900 g Approx. 750 g Approx. 1,150 g Approx. 900 g Approx. 1,500 g Approx. 1,150 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) (From April 1999) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Item G3PB- 415B-3-VD G3PB- 415B-2-VD G3PB- 425B-3-VD G3PB- 425B-2-VD G3PB- 435B-3-VD G3PB- 435B-2-VD G3PB- 445B-3-VD G3PB- 445B-2-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.8 V (RMS) max. Leakage current (See note.) 20 mA (at 400 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: –30 °C to 80°C (with no icing or condensation) Storage: –30 °C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Weight Approx. 750 g Approx. 750 g Approx. 900 g Approx. 750 g Approx. 1,150 g Approx. 900 g Approx. 1,500 g Approx. 1,150 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2
Models without Built-in Heat Sinks Note: The leakage current of phase S will be approximately times larger if the 2-element model is applied. Note: The leakage current of phase S will be approximately times larger if the 2-element model is applied. Heat Sinks Item G3PB- 215B- 3H-VD G3PB- 215B- 2H-VD G3PB- 225B- 3H-VD G3PB- 225B- 2H-VD G3PB- 235B- 3H-VD G3PB- 235B- 2H-VD G3PB- 245B- 3H-VD G3PB- 245B- 2H-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.6 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: –30 °C to 80°C (with no icing or condensation) Storage: –30 °C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) Weight (Max.) 300 g max. EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Item G3PB- 415B- 3H-VD G3PB- 415B- 2H-VD G3PB- 425B- 3H-VD G3PB- 425B- 2H-VD G3PB- 435B- 3H-VD G3PB- 435B- 2H-VD G3PB- 445B- 3H-VD G3PB- 445B- 2H-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.8 V (RMS) max. Leakage current (See note.) 20 mA (at 400 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: –30 °C to 80°C (with no icing or condensation) Storage: –30 °C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) Weight Approx. 300 g EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Model Weight Y92B-P50 Approx. 450 g Y92B-P100 Approx. 450 g Y92B-P150 Approx. 600 g Y92B-P200 Approx. 850 g Y92B-P250 Approx. 1,200 g
Load Current vs. Ambient Temperature Models with Built-in Heat Sinks G3PB-215B-3-VD G3PB-215B-2-VD G3PB-225B-3-VD G3PB-225B-2-VD G3PB-235B-3-VD G3PB-235B-2-VD Load current (A) Ambient temperature (°C) -30 -20 0 20 40 60 80 100 25 Derating curve under UL standard Load current (A) Ambient temperature (°C) −30 −20 0 20 40 60 80 100 Derating curve under UL standard Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. Load current (A) Ambient temperature (°C) −30 −20 0 20 40 60 80 100 25 Derating curve under UL standard Load current (A) Ambient temperature (°C) −30 −20 0 20 40 60 80 100 Derating curve under UL standard Load current (A) Ambient temperature (°C) −30 −20 0 20 40 60 80 100 25 Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 22 A is applicable under the UL standard only with forced air cooling by fan. Derating curve under UL standard G3PB-245B-3-VD G3PB-245B-2-VD G3PB-415B-3-VD G3PB-415B-2-VD G3PB-425B-3-VD G3PB-425B-2-VD Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. Ambient temperature (°C) −30 −20 0 20 40 60 80 100 25 42Load current (A) Derating curve under UL standard Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. Load current (A) Ambient temperature (°C) −30 −20 0 20 40 60 80 100 25 Derating curve under UL standard Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. Ambient temperature (°C) −30 −20 0 20 40 60 80 100 25 42Load current (A) Derating curve under UL standard G3PB-435B-3-VD G3PB-435B-2-VD G3PB-445B-3-VD G3PB-445B-2-VD
Models without Built-in Heat Sinks Input Voltage vs. Input Current and Input Voltage vs. Input Impedance One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. Load current (A) Ambient temperature (°C) 1.5 −30 −20 0 20 40 60 80 100 Note: Please use proper ventilation and cooling. Derating curve under UL standard G3PB-225B-3(-2)H-VD G3PB-425B-3(-2)H-VD G3PB-215B-3(-2)H-VD G3PB-415B-3(-2)H-VD Note: Please use proper ventilation and cooling. Ambient temperature (°C) 1.5 −30 −20 0 20 40 60 80 100 25 Load current (A) Derating curve under UL standard G3PB-215B-3H-VD G3PB-215B-2H-VD G3PB-415B-3H-VD G3PB-415B-2H-VD G3PB-225B-3H-VD G3PB-225B-2H-VD G3PB-425B-3H-VD G3PB-425B-2H-VD G3PB-235B-3H-VD G3PB-235B-2H-VD G3PB-245B-3H-VD G3PB-245B-2H-VD G3PB-435B-3H-VD G3PB-435B-2H-VD G3PB-445B-3H-VD G3PB-445B-2H-VD Input voltage (V) Input current (mA) Input impedance (kΩ) Input impedance Input current G3PB-215B-3 (H)-VD G3PB-215B-2 (H)-VD G3PB-225B-3 (H)-VD G3PB-425B-3 (H)-VD G3PB-225B-2 (H)-VD G3PB-415B-3 (H)-VD G3PB-425B-2 (H)-VD G3PB-415B-2 (H)-VD G3PB-235B-3 (H)-VD G3PB-235B-2 (H)-VD G3PB-245B-3 (H)-VD G3PB-245B-2 (H)-VD G3PB-435B-3 (H)-VD G3PB-435B-2 (H)-VD G3PB-445B-3 (H)-VD G3PB-445B-2 (H)-VD Inrush cur rent Energized time (ms) Energized time (ms) Energized time (ms) Inrush cur rent Inrush current
Heat Sink Area vs. Load Current Note: The heat sink area refers to the combined area of the sides of the heat sink that radiate heat. In the case of G3PB-425B-3H-VD, when a current of 18 A is allowed to flow through the SSR at 40°C, the graph shows that the heat sink area is about 2,500 cm2. Therefore, if the heat sink is square, one side of the heat sink must be 36 cm (362 × 2 = 2,592) or longer. Thermal Resistance Rth (Junction/SSR Back Surface) Three-phase Models without Heat Sink G3PB-225B-3H-VD G3PB-425B-3H-VD Ambient temperature: 80°C Ambient temperature: 40°C Load current (A) Heat sink area (cm2) Aluminum plate (t=3.0 mm) Ambient temperature: 80°C Ambient temperature: 40°C Load current (A) Aluminum plate (t=3.0 mm) Heat sink area (cm2) Model Rth ( °C/W) G3PB-215B-3H-VD 1.05 G3PB-225B-3H-VD 0.57 G3PB-235B-3H-VD 0.57 G3PB-245B-3H-VD 0.57
Note: All units are in millimeters unless otherwise indicated. Models with Built-in Heat Sinks 0.5 20 20 32.2 Two, M3.5 × 8 Six, M4 × 12 80 max. 80.5 max. 100 max. 4.6 dia. Elliptical hole: 4.6 × 5.6 50±0.3 90±0.3 Two, 4.5 dia. or M4 Mounting holes 55 max. 30.5 max.19.414.6 Terminal Arrangement/Internal Circuit Diagram L1/R T1/U T2/V T3/W L2/S L3/T Input circuit Input circuit (+) (−) (+) (−) G3PB-215B-2-VD L1/R T1/U T2/V T3/W L2/S L3/T G3PB-415B-2-VD G3PB-215B-2-VD G3PB-415B-2-VD Without Terminal Cover With Terminal Cover Input circuit Input circuit Input circuit Input circuit (+) (−) (+) (−) (+) (−) (+) (−) Terminal Arrangement/Internal Circuit Diagram G3PB-225B-2-VDG3PB-215B-3-VD L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T G3PB-425B-2-VD L1/R T1/U T2/V T3/W L2/S L3/T G3PB-415B-3-VD 80 max. 100 110.5 max. 80.5 max. 0.5 20 20 32.2 60±0.3 100±0.3 Four, 4.5 dia or M4 70 max. 30.5 max. Four, R2.5 Two, M3.5 × 8 Six, M4 × 12 Mounting Holes 19.414.6 G3PB-215B-3-VD G3PB-225B-2-VD G3PB-415B-3-VD G3PB-425B-2-VD Without Terminal Cover With Terminal Cover
80.5 max. 90 80 max. 100 110.5 max. 110.5 max. 0.5 20 20 32.2 90±0.3 100±0.3 Four, 4.5 dia or M4 70 max. 30.5 max. Four, R2.5 Two, M3.5 × 8 Six, M5 × 12 (G3PB-@35B-2-VD) Six, M4 × 12 (G3PB-@25B-3-VD) Mounting Holes 19.414.6 G3PB-225B-3-VD G3PB-235B-2-VD G3PB-425B-3-VD G3PB-435B-2-VD (+) (−) (+) (−) (+) (−) (+) (−) Terminal Arrangement/Internal Circuit Diagram G3PB-235B-2-VDG3PB-225B-3-VD L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T Input circuit Input circuit Input circuit Input circuit Input circuit G3PB-435B-2-VD L1/R T1/U T2/V T3/W L2/S L3/T G3PB-425B-3-VD Without Terminal Cover With Terminal Cover 80.5 max. 90 80 max. 120 130.5 max. 130.5 max. 0.5 20 20 32.2 90±0.3 120±0.3 Four, 4.5 dia or M4 70 max. 30.5 max. Four, R2.5 Two, M3.5 × 8Six, M5 × 12 Mounting Holes 19.414.6 G3PB-235B-3-VD G3PB-245B-2-VD G3PB-435B-3-VD G3PB-445B-2-VD Input circuit Input circuit Input circuit Input circuit (+) (−) (+) (−) (+) (−) (+) (−) Terminal Arrangement/Internal Circuit Diagram G3PB-245B-2-VDG3PB-235B-3-VD L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T G3PB-445B-2-VD L1/R T1/U T2/V T3/W L2/S L3/T G3PB-435B-3-VD Without Terminal Cover With Terminal Cover
80.5 max. 150 80 max. 120 130.5 max. 190.5 max. 0.5 20 20 32.2 150±0.3 120±0.3 Four, 4.5 dia or M4 70 max. 30.5 max. Four, R2.5 Two, M3.5 × 8 Six, M5 × 12 Mounting Holes 19.414.6 A2 Input circuit Input circuit (+) (−) (+) (−) Terminal Arrangement/Internal Circuit Diagram G3PB-245B-3-VD L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T G3PB-445B-3-VD G3PB-245B-3-VD G3PB-445B-3-VD Without Terminal Cover With Terminal Cover
Models without Built-in Heat Sinks Heat Sinks 30.5 max.19.414.6 80.5 max. 80 max. 2468 0.5 20 20 32.2 Four, 8 dia. Four, 4.5 dia. Two, M3.5 × 8 Four, 4.5 dia or M4 68±0.3 68±0.3 Mounting Holes Six, M4 × 12 (G3PB-@15B@H-VD/-@25B-@H-VD) Six, M5 × 12 (G3PB-@35B-@H-VD/-@45B-@H-VD) G3PB-215B-3H-VD G3PB-215B-2H-VD G3PB-225B-3H-VD G3PB-225B-2H-VD G3PB-235B-3H-VD G3PB-235B-2H-VD G3PB-245B-3H-VD G3PB-245B-2H-VD G3PB-415B-3H-VD G3PB-415B-2H-VD G3PB-425B-3H-VD G3PB-425B-2H-VD G3PB-435B-3H-VD G3PB-435B-2H-VD G3PB-445B-3H-VD G3PB-445B-2H-VD A2 Input circuit (+) (−) Input circuit (+) (−) Input circuit (+) (−) Input circuit (+) (−) Terminal Arrangement/Internal Circuit Diagram G3PB-2@5B-2H-VDG3PB-2@5B-3H-VD L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T L1/R T1/U T2/V T3/W L2/S L3/T G3PB-4@5B-2H-VD L1/R T1/U T2/V T3/W L2/S L3/T G3PB-4@5B-3H-VD Without Terminal Cover With Terminal Cover Y92B-P100 For G3PB-215B-3H-VD G3PB-225B-2H-VD G3PB-415B-3H-VD G3PB-425B-2H-VD 110.5 max. 6068 Four, M4 100 80.5 max. 70 max. Four, R2.5 60±0.3 100±0.3 Four, 4.5 dia. or M4 Mounting Holes Y92B-P50 For model G3PB-215B-2H-VD G3PB-415B-2H-VD 4.6 dia. 80 max. 55 max. Mounting Holes Two, 4.5 dia. or M4 80.5 max. 100 max. Elliptical hole: 4.6 x 5.6
Accessories (Order Separately) 90±0.3 100±0.3 Four, 4.5 dia. or M4 Mounting Holes 9068 100 110.5 max. 110.5 max. 70 max. Four, M4 Four, R2.5 Y92B-P150 For model G3PB-225B-3H-VD G3PB-235B-2H-VD G3PB-425B-3H-VD G3PB-435B-2H-VD Y92B-P200 For model G3PB-235B-3H-VD G3PB-245B-2H-VD G3PB-435B-3H-VD G3PB-445B-2H-VD Mounting Holes 120 70 max. 120 130.5 max. Four, M4 Four, R2.5 90±0.3 120±0.3 90 130.5 max. Four, 4.5 dia. or M4 Y92B-P250 For model G3PB-245B-3-VD G3PB-445B-3-VD 68 47.6 Four, M4 Depth10 Depth10 120 120 130.5 max. 190.5 max. 70 max. Four, R2.5 150 150±0.3 120±0.3 Four, 4.5 dia. or M4 Mounting Holes PFP-100N, PFP-50N PFP-100N2 35±0.3 4.5 7.3±0.15 27±0.15 35±0.3 27 24 29.2 1.51 4.5 15 25 10 25 25 2510 25 2510 1,000 25 25 1510 Mounting Tracks 15 (5) (see note)1,000 (500) (see note) Note: Values in parentheses indicate dimensions for the PFP-50N. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.