G3CN-DX02P1-DC3-28 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
PCB-mounting SSR for FA Equipment Requiring High Reliability Wide I/O voltage range: 3 to 28 VDC input and 75 to
264 VAC output or 3 to 28 VDC input and 3 to
52.8 VDC output. Two load currents available: 2 A and 3 A Flat and vertical models available for a variety of applications. Approved by UL and CSA. RC
Ordering Information
Indicator Rated output voltage (Applicable output load) Rated input voltage Model Photocoupler Yes No 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 4 to 24 VDC G3CN-202P-US G3CN-202P1-US*
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC) G3CN-203P-US G3CN-203P1-US* Phototriac No 2 A at 100 to 240 VAC (2 A at 75 to 264 VAC) 5, 12, 24 VDC** G3CN-202PL-US G3CN-202PL1-US* (3 A at 75 to 264 VAC) G3CN-203PL-US G3CN-203PL1-US* Photocoupler --- 2 A at 4 to 48 VDC (2 A at 3 to 52.8 VDC) 4 to 24 VDC G3CN-DX02P-US G3CN-DX02P1-US*
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC) G3CN-DX03P-US G3CN-DX03P1-US* *Vertical models. **When ordering, specify the input voltage
Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage G3CN-202P(1)-US G3CN-203P(1)-US 4 to 24 VDC 3 to 28 VDC 1.5 kΩ +20% /–10% 3 VDC max. 1 VDC min. G3CN-202PL(1)-US G3CN 203PL(1) US 5 VDC 4 to 6 VDC 390 Ω ±20% 4 VDC max.G3C 0 ( ) US G3CN-203PL(1)-US 12 VDC 9.6 to 14.4 VDC 900 Ω ±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 kΩ ±20% 19.2 VDC max. G3CN-DX02P(1)-US G3CN-DX03P(1)-US 4 to 24 VDC 3 to 28 VDC 1.5 kΩ +20% /–10% 3 VDC max. Note: The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the input impedance is measured at 28 VDC. Output Model Applicable load Rated load voltage Load volage range Load current Inrush current W ithout heat sink G3CN-202P(1)-US G3CN-202PL(1)-US 100 to 240 VAC 75 to 264 VAC 0.1 to 2 A 30 A (60 Hz, 1 cycle) G3CN-203P(1)-US G3CN-203PL(1)-US 0.1 to 3 A 45 A (60 Hz, 1 cycle) G3CN-DX02P(1)-US 4 to 48 VDC 3 to 52.8 VDC 0.1 to 2 A 12 A (10 ms) G3CN-DX03P(1)-US 0.1 to 3 A 18 A (10 ms) Characteristics Item G3CN-202P(1)/203P(1)-US G3CN-202PL(1)/203PL(1)-US G3CN-DX02P(1)/03P(1)-US Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. 0.5 ms max. Release time 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 2 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.5 V max. Leakage current 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 5 mA max. (at 50 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: –30°C to 80°C (with no icing nor condensation) Storage: –30°C to 100°C (with no icing nor condensation) Ambient humidity Operating: 45% to 85% Weight Approx. 25 g
Load Current vs. Ambient Temperature Characteristics G3CN-202P(1)/-202PL(1)/-DX02P(1)-US Ambient temperature (°C) Load current (A) G3CN-203P(1)/-203PL(1)/-DX03P(1)-USLoad current (A) Ambient temperature (°C) G3CN-203P(1)/-203PL(1)-US G3CN-DX02P(1)-US Inrush current (A. Peak) Energizing time (ms) Inrush current (A. Peak) Energizing time (ms) Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3CN-202P(1)/-202PL(1)-US G3CN-DX03P(1)-US Inrush current (A. Peak) Inrush current (A. Peak) Energizing time (ms) Energizing time (ms)
Note: All units are in millimeters unless otherwise indicated. Input voltage Terminal Arrangement/ Internal Connections (Bottom View) Flat Model G3CN-20 /C0106P/-20/C0106PL/-DX0/C0106P Vertical Model G3CN-20 /C0106P1/-20/C0106PL1/-DX0/C0106P1 (–) (+) (–) (+) Input Load Load Load power supply Note: Values in parentheses apply to the DC-load versions. 4 3 2 1 –+ (–) (+) – + (–) (+) Input Load Load Input voltage Load power supply Note: Values in parentheses apply to the DC-load versions. 0.4 33 max. 25 max. 14.5 max.20 max. 1.5 max. 25±0.5 12.5±0.5 10±0.5 0.7 0.7 0.7 0.4 33 max. 14 max. 26.5 max. 32 max. 1.5 max. 27.5±0.5 (17.5) 5±0.5 3 ±1 Four 1.2-dia. holes 25 12.5 5 (17.5) 5 27.5 Two, 2-dia. holes Two, 4 dia. holes Two, 2-dia. holes Four 1.2-dia. holes Pattern Pattern Terminal Arrangement/ Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Bottom View) Terminal Arrangement/ Mounting Holes (Bottom View) 5±0.5
Refer to pages 11 to 19 for general precautions. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Protective Component Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption compo- nent when using the SSR under an inductive load. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K063-E1-2A
Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3CN-DX02P1-DC3-28