G3PRESSURE ASHCROFT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Metri-Pack® and Superseal®. For more information, see Ashcroft Brands & Trademarks Data Sheet G3 Pressure Transducer of 4

FEATURES

All-welded 316L stainless steel sensor and pressure connection Highly configurable; wide selection of pressure connections and electrical terminations Ranges vacuum to 5000 psi NSF-61 Compliant TYPICAL USES Performance vehicle racing Railroad/transportation Agriculture implements Compressor control HVAC and refrigeration Process automation and control Pump monitoring KEY BENEFITS

  • Broad temperature capability
  • High EMI/RFI immunity ratings
  • IP67 Ingress rating
  • High performance ASIC based electronics SPECIFICATIONS Reference Temperature: Accuracy Class (BFSL): ± 0.50% of span Accuracy (TEB): ±1.5% of Span: From -20 to 85 °C (-4 to 185 °F) ±2.0% of Span: From -40 to -20 °C (-40 to -4 °F) ±2.0% of Span: From 85 to 125 °C (185 to 257 °F) Total Error Band Accuracy: includes the combined effects of non-linearity (Terminal Point Method), hys- teresis, non-repeatability, temperature and zero offset and span setting errors Stability: ≤ ±0.25% of span/year Durability: > 10 million cycles Approvals: NSF-61, CE/UKCA, CE, UL (UL 61010-1), (CSA 222 6101-1) UL Recognized component per UL-61010-1, CSA 22.2 6101-1 Electrical Equipment for Measurement, Control and Laboratory use ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Compensated: -40 °F to 257 °F (-40 °C to +125 °C) -40 °F to 257 °F (-40 °C to +125 °C) -40 °F to 257 °F (-40 °C to +125 °C) Humidity Effects: 0 to 100% R.H., no effect FUNCTIONAL SPECIFICATIONS Vibration Effects: Random vibration (20 g) over temperature range (-40 °C to 125 °C) Shock Effects: 100 gs, 6 ms Drop Test: Withstands 1 meter on concrete Response Time: <2 ms Transducer FUNCTIONAL SPECIFICATIONS Pressure Ranges: Vacuum, compound, gauge 5 to 5000 psig and absolute 15 to 500 psia Warm-up Time: > 500 msec Position Effect: < ±0.01% span Overpressure: ≤200 psi 300 to 5000 psi Proof Burst 2X Range 5X Range 1.5X Range 3X Range ELECTRICAL SPECIFICATIONS Reverse Polarity & Miswired Protected: Yes Insulation Breakdown Voltage: 100 Vac Insulation Resistance: >100 Mh @ 100 Vdc Circuit Protection: Reverse polarity and miswire protection

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Metri-Pack® and Superseal®. For more information, see Ashcroft Brands & Trademarks Data Sheet G3 Pressure Transducer of 4 OUTPUT SIGNALS AVAILABLE Voltage Output Excitation Supply Current 0-5 Vdc, 3 wire 9-36 Vdc 5 mA 0-10 Vdc, 3 wire 14-36 Vdc 5 mA 1-5 Vdc, 3 wire 9-36 Vdc 4 mA 1-6 Vdc, 3 wire 9-36 Vdc 4 mA 0.5-4.5 Vdc 3 wire 9-36 Vdc 4 mA Ratiometric Output Current Output 4-20 mA, 2 wire 9-36 Vdc ENVIRONMENTAL RATING Rating Electrical Connections IP67, NEMA 4X Metri-Pack®, Shielded cable, Flying leads Deutsch® DT & DTM, AMP® Superseal® and M12 IP65, NEMA 4X Hirschmann® G, EN 175301-803 Form C (DIN 43650 C) OPTIONAL FEATURES Electrical Termination: See Ordering Code Process Connection Location: See Ordering Code Consult Factory For: Pressure range options, Process connection locations, Approval descriptions WETTED COMPONENTS Diaphragm 316L Stainless Steel Process Connection 316L Stainless Steel NON-WETTED COMPONENTS Housing 20% Glass Reinforced Nylon, Fire retardant to UL94 V1 TOTAL ERROR BAND (TEB) Error limits of all points (0-100% of range) POWER SUPPLY & LOAD RESISTANCE TOT AL ERR OR B AND (TEB) Err or limits of all points (0-100% of range) Err or (% of span) Ambient T emperature (C) -60 -40 -20 0 20 40 60 80 100 120 140 2.0% 1.5% 1.0% 0.5% 0.0% -0.5% -1.0% -1.5% -2.0% P os Err or Limit Neg Err or Limit 10 40 9 (min) 36 (max) Loop Supply Voltage (Vdc) [LSV] Power Supply Voltage vs. Loop Resistance (4-20 mA ONLY) Loop Resistance (RL-Ohms) 1400 1200

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Metri-Pack® and Superseal®. For more information, see Ashcroft Brands & Trademarks Data Sheet G3 Pressure Transducer of 4 ORDERING CODE Example: G37 M01 42 M2 60# G - XTU Model G37 - G3 Series, 1.5% Total Error Band -20 °C to 85 °C, 2.0%Total Error Band -40 °C to -20 °C and 85 °C to 125 °C G37 Pressure Connection Size M01 - 1⁄8 NPT - Male M01 M02 - 1/4 NPT - Male MEK - 7⁄16 20 SAE #4 - Male, not UL reconginzed over 10,000 psi range MEV - 9⁄16-18 SAE #6 Male w/Buna-N O-ring, not UL recognized over 10,000 psi range MS2 - 1/4-19 bsp - Male, not UL recognized over 10,000 psi range MG2 - G 1/4 B - Male M38 - 3⁄8-24 SAE #3 Male w/Buna-N O-ring M33 - 3⁄8-24 UNJF3A (w/37 ° cone seat) M76 - 7⁄16 -20 UNJF3A (w/37 ° cone seat) Output Signal 5 - 0-5 Vdc 10 - 0-10 Vdc 15 - 1-5 Vdc 16 - 1-6 Vdc 42 - 4-20 mA 42 RM - 0.5-4.5 Vdc Ratio metric to 5 Vdc supply 45 - 0.5 - 4.5 Vdc Ratio metric to 9-36 Vdc supply Electrical Termination EN 175301-803 Form C (DIN 43650, Form C) DC - No mating connector N1 - Mating connector, no cable N2 - Mating connector, 1 meter (3 feet) of cable N3 - Mating connector, 3 meter (10 feet) of cable N9 - Mating connector with customer specified length M12 - Mates to Hirschmann ® 933 172-100 or similar EW - No mating connector E0 - W/mating connector, no cable E2 - W/mating connector, 1 meter (3 feet) of shielded cable E4 - W/mating connector, 3 meter (10 feet) of shielded cable E1 - W/mating connector, customer defined cable length Pigtail - Shielded cable with PVC jacket and 24 AWG leads F2 - W/1 meter (3 feet) cable length F3 - W/3 meter (10 feet) of cable length P1 - Customer specified length Metri-Pack ® GN - No mating connection G2 - Mating connection with 1 meter (3 feet) of cable G3 - Mating connection with 3 meter (10 feet) of cable G1 - Mating connector with customer specified length Hirschmann ® G Series HM - No mating connection M1 - W/mating connector , no cable M2 - Mating connection with 1 meter (3 feet) of cable M2 P9 - Mating connector with customer specified length Flying Leads W2 - 1 meter (3 feet) of flying leads W9 - Customer specifed length Deutsch ® DT Series DT04-3P DT - Without mating connector T2 - W/1 meter (3 feet) of cable T3 - W/3 meter (10 feet) of cable T1 - W/mating connector, customer specified length Deutsch ® DT Series DTM04-3P DS- Without mating connector S2 - W/1 meter (3 feet) of cable S3 - W/3 meter (10 feet) of cable S1 - W/mating connector, customer specified length AMP® Superseal ® AP - Without mating connector A2 - W/1 meter (3 feet) of cable A3 - W/3 meter (10 feet) of cable A1 - W/mating connector, customer specified length Pressure Ranges (see range table on page 4) 60# - 60 psi 60# Measurement Type G - Gauge G Option (if including an option(s) must include an “X’’) X _ _ TU - Throttle Plug TU

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, AMP®, Deutsch®, Metri-Pack® and Superseal®. For more information, see Ashcroft Brands & Trademarks Data Sheet G3 Pressure Transducer of 4 Ø0.95 [Ø24.0] 1.69 [42.9] 1.74 [44.2] 2.60 [65.9] 0.23 [5.7] ¼ NPT 1.40 1.59 .23 .94 1.06 [27] 1.06 [27] [36] MINI HIRSCHMANN®** [24] .94 [24] .71 [18] 2.24 [57] [6] 2.05 [52] .30 [8] .23 [6] [40] Wire Length 3-PIN METRI-PACK®*AMP® SUPERSEAL® DEUTSCH® DT04-3P DEUTSCH® DTM04-3P .23 Ø.94 2.03 .45 1.02 1.06 .54 2.11 .56 .23 .94 .95 1.13 1.06 .44 .23 2.04 .46 Ø.94 1.06 .81 .67 Optional Mating Connector Optional Mating Connector *Mates to Metri-Pack® Connector Body 12065286 Mates to Hirschmann® G4W1F Connector or Similar 1.40 1.59 .23 .94 1.06 [27] 1.06 [27] [36] MINI HIRSCHMANN® [24] .94 [24] .71 [18] 2.24 [57] [6] 2.05 [52] .30 [8] .23 [6] [40] Wire Length 3-PIN METRI-PACK®*AMP® SUPERSEAL® DEUTSCH® DT04-3P DEUTSCH® DTM04-3P .23 Ø.94 2.03 .45 1.02 1.06 .54 2.11 .56 .23 .94 .95 1.13 1.06 .44 .23 2.04 .46 Ø.94 1.06 .81 .67 Optional Mating Connector Optional Mating Connector *Mates to Metri-Pack® Connector Body 12065286 Mates to Hirschmann® G4W1F Connector or Similar 1.40 1.59 .23 .94 1.06 [27] 1.06 [27] [36] MINI HIRSCHMANN® [24] .94 [24] .71 [18] 2.24 [57] [6] 2.05 [52] .30 [8] .23 [6] [40] Wire Length 3-PIN METRI-PACK®*AMP® SUPERSEAL® DEUTSCH® DT04-3P DEUTSCH® DTM04-3P .23 Ø.94 2.03 .45 1.02 1.06 .54 2.11 .56 .23 .94 .95 1.13 1.06 .44 .23 2.04 .46 Ø.94 1.06 .81 .67 Optional Mating Connector Optional Mating Connector *Mates to Metri-Pack® Connector Body 12065286 **Mates to Hirschmann® G4W1F Connector or Similar

3.992 TYP

.793 Flange Radius Major thread Radius R.211 Connection - PINConnection - PIN Vs- V out Vs+ Vs- Vs+ G3 RANGE TABLE Range Code 316SS 316SS ISO Gauge 5 psi 5# X 15 psi 15# X* X 30 psi 30# X X 50 psi 50# X X 60 psi 60# X X 100 psi 100# X X 150 psi 150# X X 250 psi 250# X X 300 psi 300# X X 500 psi 500# X X 750 psi 750# X X 1,000 psi 1000# X X 1,500 psi 1500# X X 2,000 psi 2000# X X 3,000 psi 3000# X X 5,000 psi 5000# X X Compound 0 psi/-14.7 psi 0#&vac X* X 15 psi/-14.7 psi 15#&vac X* X 30 psi/-14.7 psi 30#&vac X 60 psi/-14.7 psi 60#&vac X 100 psi/-14.7 psi 100#&vac X 150 psi/-14.7 psi 150#&vac X 300 psi/-14.7 psi 300#&vac X Absolute 15 psi 15# X 30 psi 30# X 50 psi 50# X 60 psi 60# X 100 psi 100# X 250 psi 250# X 300 psi 300# X 500 psi 500# X Connection - PINConnection - PIN Vs- V out Vs+ Vs- Vs+ * Not available with 4-20mA output DIMENSIONS are identified in inches and [millimeters] For reference only, consult Ashcroft for specific dimensional drawings. G3 Range Table Range Code 316LSS 316LSS ISO Gauge 5 psi 5# X 15 psi 15# X* X 30 psi 30# X X 50 psi 50# X X 60 psi 60# X X 100 psi 100# X X 250 psi 250# X X 300 psi 300# X X 500 psi 500# X X 1,000 psi 1000# X X 1,500 psi 1500# X X 2,000 psi 2000# X X 3,000 psi 3000# X X 5,000 psi 5000# X X Compound 0 psi/-14.7 psi 0#&vac X* X 15 psi/-14.7 psi 15#&vac X* X 30 psi/-14.7 psi 30#&vac X 60 psi/-14.7 psi 60#&vac X 100 psi/-14.7 psi 100#&vac X 150 psi/-14.7 psi 150#&vac X 300 psi/-14.7 psi 300#&vac X Absolute 15 psi 15# X 30 psi 30# X 50 psi 50# X 60 psi 60# X 100 psi 100# X 250 psi 250# X 300 psi 300# X 500 psi 500# X * Not available with 4-20mA output