G2R-@-S (S) Slim and Space-saving Power Plug-in Relay ■ Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements). ■ Lockable test button models available. ■ Built-in mechanical operation indicator. ■ Provided with nameplate. ■ AC type is equipped with a coil-disconnection self-diagnostic function (LED type). ■ High switching power (1-pole: 10 A). Model Number Structure Model Number Legend 1. Number of Poles 1: 1 pole 2: 2 poles 2. Terminals S: Plug-in 3. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 4. Rated Coil Voltage 5. Mechanical operation indicator and Nameplate (S): Models with mechanical oper ation indicator and Nameplate Note: Contact your OMRON representative for Relays with gold-plated contacts.
Ordering Information
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina- tions with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. LR For the most recent information on models that have been certified for safety standards, refer to your OMRON website. G2R - - 12 3 4 5 S (S) 8IFOZPVSPSEFS TQFDJGZUIFSBUFEWPMUBHF Classification Coil ratings Contact form SPDT DPDT General-purpose AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 G2R-1-S (S) G2R-2-S (S) LED indicator G2R-1-SN (S) G2R-2-SN (S) LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode DC 6, 12, 24, 48 G2R-1-SD (S) G2R-2-SD (S) LED indicator and diode G2R-1-SND (S) G2R-2-SND (S) LED indicator and diode with test button G2R-1-SNDI (S) G2R-2-SNDI (S) When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. Example: G2R-1-S 12 VDC (S) Rated coil voltage
G2R-@-S (S) Accessories (Order Separately) Connecting Sockets * The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals. Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU) Short Bars Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box ( @) in the model number with the code for the covering color. Labels Mounting Tracks *1.When mounting DIN rail, please use End Plate (PFP-M). *2.Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. Track/surface-mounting Socket Back-mounting Socket Applicable Relay model Push-In Plus Terminal Blocks Screw terminals * PCB terminals Solder terminals No. of poles Model Models Models Model 1 pole G2R-1-S (S) P2RF-05-PU P2RF-05 P2RF-05-E P2R-05P P2R-057P P2R-05A 2 poles G2R-2-S (S) P2RF-08-PU P2RF-08 P2RF-08-E P2R-08P P2R-087P P2R-08A Pitch No. of poles Colors Model * Minimum order (quantity) 7.75 mm Red (R) Blue (S) Yellow (Y) PYDN-7.75-020@ 3 PYDN-7.75-030@ 4 PYDN-7.75-040@ 20 PYDN-7.75-200@ 15.5 mm 8 PYDN-15.5-080@ Model Minimum order (sheet) (quantity per sheet) XW5Z-P4.0LB1 5 1 sheet (60 pieces) Applicable Socket Description Model Minimum order (quantity) Track-connecting Socket Mounting track 50 cm (l) × 7.3 mm (t): PFP-50N ---1 m (l) × 7.3 mm (t): PFP-100N 1 m (l) × 16 mm (t): PFP-100N2 End plate *1 PFP-M Spacer PFP-S Back-connecting Socket Mounting plate *2 P2R-P 1
G2R-@-S (S) Specifications Coil Ratings Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current and ±10% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. Contact Ratings Note: P level: λ60 = 0.1 x 10-6/operation * This value was measured at a switching frequency of 120 operations per minute. Rated voltage Rated current* Coil resistance Coil inductance (H) (ref. value) Must operate voltage Must release voltage Max. voltage Power consumption (approx.)50 Hz 60 Hz Armature OFF Armature ON % of rated voltage AC 24 V 43.5 mA 37.4 mA 253 Ω 0.81 1.55 80% max. 30% max. 110% 0.9 VA at 60 Hz 110 V 9.5 mA 8.2 mA 5,566 Ω 13.33 26.83 120 V 8.6 mA 7.5 mA 7,286 Ω 16.13 32.46 230 V 4.4 mA 3.8 mA 27,172 Ω 72.68 143.90 240 V 3.7 mA 3.2 mA 30,360 Ω 90.58 182.34 Rated voltage Rated current* Coil resistance Coil inductance (H) (ref. value) Must operate voltage Must release voltage Max. voltage Power consumption (approx.)Armature OFF Armature ON % of rated voltage DC 6 V 87.0 mA 69 Ω 0.25 0.48 24 V 21.6 mA 1,113 Ω 3.60 8.25 48 V 11.4 mA 4,220 Ω 15.2 29.82 Number of poles 1 pole 2 poles Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current 10 A 5 A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A 5 A Max. switching power 2,500 VA, 300 W 1,875 VA, 150 W 1,250 VA, 150 W
500 VA,
Failure rate (reference value) * 100 mA at 5 VDC 10 mA at 5 VDC
G2R-@-S (S) Characteristics Note: Values in the above table are the initial values. * These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets. Approved Standards UL 508 (File No. E41643) CSA 22.2 No.0, No.14 (File No. LR31928) IEC/VDE (Certificate No. 40015012 EN 61810-1) LR Item 1 pole 2 poles Contact configration SPDT Contact structure Single Contact resistance 100 mΩ max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength * 5,000 VAC, 50/60 Hz for 1 min between coil and contacts; 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 5,000 VAC, 50/60 Hz for 1 min between coil and contacts; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: 1,000 m/s 2 Malfunction: 200 m/s 2 when energized; 100 m/s2 when not energized Endurance Mechanical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) Ambient temperature Operating: –40 °C to 70°C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 20 g Model Contact form Coil ratings Contact ratings Opera- tions G2R-1-S (S) SPDT 5 to 110 VDC 6 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 10 3 G2R-2-S (S) DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 10 3 Model Contact form Coil ratings Contact ratings Opera- tions G2R-1-S (S) SPDT 5 to 110 VDC 6 to 240 VAC TV-3 (NO contact only) 25 × 10 3 G2R-2-S (S) DPDT TV-3 (NO contact only) 25 × 10 3 Contact form Coil ratings Contact ratings Operations 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0) 10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 × 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms) 100 × 103
of poles Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4) 5A, 30VDC (L/R=7ms) 100 × 10 2 poles 5 to 110 VDC 6 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4) 3A, 30VDC (L/R=7ms) 100 × 103
G2R-@-S (S) Engineering Data Maximum Switching Power Endurance Ambient Temperature vs Maximum Coil Voltage 100 0.11 10 100 1000 100 0.11 10 100 1000 G2R-1-S (S)Switching current (A) Switching voltage (V) G2R-2-S (S) Switching voltage (V) Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load DC resistive load DC inductive load (L/R = 7 ms) AC inductive load (cosφ = 0.4) AC resistive load DC resistive load DC inductive load (L/R = 7 ms) 5,000 1,000 500 100 5,000 1,000 500 100 10,000 G2R-1-S (S)Endurance (x103 operations) Switching current (A) G2R-2-S (S) Switching current (A) 30-VDC inductive load (L/R = 7ms) 30-VDC inductive load (L/R = 7ms) Endurance (x103 operations) 250-VAC/30-VDC resistive load 250-VAC inductive load (cosφ = 0.4) 250-VAC/30-VDC resistive load 250-VAC inductive load (cosφ = 0.4) Ambient temperature (°C) Maximum voltage (%) DC coil AC coil
G2R-@-S (S) Dimensions (Unit: mm) Note: All units are in millimeters unless otherwise indicated. SPDT Relays DPDT Relays G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S) G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) 2 345 DC24V 201 0.5 4.75 7.5 17.5 5.25.2 35.5 max. 29 max. 13 max. G2R-1-SND (S), G2R-1-SNDI (S) (DC) G2R-1-S (S) G2R-1-SD (S) (DC) G2R-1-SN (S), G2R-1-SNI (S) (AC) G2R-1-SN (S), G2R-1-SNI (S) (DC) 2 345 2 45 2 45 2 345 G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S) G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-SND (S), G2R-2-SNDI (S) (DC) G2R-2-S (S) G2R-2-SD (S) (DC) G2R-2-SN (S), G2R-2-SNI (S) (AC) G2R-2-SN (S), G2R-2-SNI (S) (DC) 0.5 2.5 2.4 19.4 29 max. 35.5 max. 13 max. 6.2 7.4 8.9 234 765 234 567 234 765 234 765 234 765
G2R-@-S (S) Track/Surface Mounting Sockets Mounting Hole Dimensions 52.4 36.3 27.6 27.25 35.5 28.1 27.6 52.1 3.9 56.5 max. 15.5 max. 90 max. (3) (3) 3FMFBTFMFWFS A1 A2 Terminal Arrangement/ Internal Connection Diagram (Top View) (5) (2) (4) (3) (1) Two M4 screw holes or two 4-dia. holes 108 P2RF-05-PU Note: Pull out the hooks to mount the Relay with screws. Note: The numbers in parentheses are traditionally used terminal numbers. Mounting Hole Dimensions 27.6 28.1 36.3 27.6 35.5 27.25 52.1 52.4 3.9 56.5 max. 15.5 max. (3) (3) 90 max. 3FMFBTFMFWFS A1 A2 Terminal Arrangement/ Internal Connection Diagram (Top View) (8) (2) (4) (3) (7) (5) (6) (1) Two M4 screw holes or two 4-dia. holes 108 P2RF-08-PU Note: Pull out the hooks to mount the Relay with screws.Note: The numbers in parentheses are traditionally used terminal numbers. Accessories for P2RF-@-PU Short Bars PYDN-7.75-@@ (7.75 mm) PYDN-15.5-080@ (15.5 mm) 3.90 L 1.572.25 18.5 3.90 1.572.25 18.5 115.85 * Replace the box (@) in the model number with the code for the covering color. Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets. 2. When using short bar to coil terminals of P2RF-@@-PU, A1 terminal cannot be used. In case crossover wiring of A1 terminal side is needed, crossover wiring using A1 terminals by wire is possible. Short bar correspondence table Application Pitch No. of poles L (Length) Colors Model * Maximum carry current For Contact terminals (common) 7.75 mm 21 5 . 1 Red (R) Blue (S) Yellow (Y) PYDN-7.75-020@ 20 A 3 22.85 PYDN-7.75-030@ 43 0 . 6 PYDN-7.75-040@ 20 154.6 PYDN-7.75-200@ For Coil terminals 15.5 mm 8 115.85 PYDN-15.5-080@ Contact terminal (Common) Coil terminal A1 A2 P2RF-@@-PU Available --- ❍
G2R-@-S (S) 39.5±0.1 P2RF-05 P2RF-08 35.5 19.5 30±0.05 35.5 19.5 30±0.05 P2RF-05-E 39.5 35.5 11.5 (11) (14) (12) (A1) (A2) 39.5±0.1 2 1.5 39.5 35.5 11.5 P2RF-08-E 6 3 7 2 (A1) (A2) (21) (22) (24) (11) (12) (14) 3.2-dia. hole Five, M3.5 x 8 19.5 max. 4-dia. holes 30 max. 54 max. 4.2-dia. hole 71.5 max. 19.5 max. Eight, M3.5 x 8 4-dia. holes 30 max. 54 max. 4.2-dia. hole 3.2-dia. hole Five, M3.5´7 85.5 max. 16.0 max. 48 max. Note: Pin numbers in parentheses apply to DIN standard. 61 max. Eight, M3´8 3.5-dia. hole 16.0 max. 48.0 max. 61.0 max. Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) M3 or 3.5-dia. hole M3 or 3.5-dia. hole 3.5-dia. hole 85.5 max. M3 or 3.2-dia. hole M3 or 3.2-dia. hole Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 71.5 max. 7±0.2 6+0.2−0.1
G2R-@-S (S) Mounting Height of Relay with Track/Surface Mounting Sockets Back-connecting Sockets P2RF-@ P2RF-@-E P2RF-05-PU P2RF-08-PU G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-@-E Socket P2RF Socket 66.5 62.0 67.0 70.5 G2R-@-S (S) Relay G2R-@-S (S) Relay 63.6 28.1 (3.9) 63.6 28.1 (3.9) 1 47 4.5 3.5 1.2 1.5 7 4 4.5 4 70.3 2.8 1.5 7.5 7.5 (4.3) (5) P2R-05P (1-pole) 14.5 max. 35.5 max. Tolerance: ±0.1 Mounting Holes P2R-08P (2-pole) 36.5 max.Terminal plate thickness: 0.3 14.5 max. 35.5 max. Eight, 1.3-dia. holes Terminal Arrangement (Bottom View) Mounting HolesTerminal Arrangement (Bottom View) Five, 1.6-dia. holes 36.5 max.
G2R-@-S (S) Mounting Height of Relay with Back-connecting Sockets 4.5 1.20.3 6.7 3.8 16.7 5 1.2 0.3 2.8 2.6 7.5 13.6±0.1 30.5±0.2 1.5 7.5 7.56.5 P2R-05A (1-pole) Panel Cutout P2R-08A (2-pole) Five, 3 x 1.8-dia. holes 36.5 max.Terminal plate thickness: 0.3 14.5 max. 35.5 max. 36.5 max.Terminal plate thickness: 0.3 14.5 max. 35.5 max. Eight, 3 x 1.2-dia. holes Terminal Arrangement (Bottom View) Recommended thickness of the panel is 1.6 to 2.0 mm P2R-057P (1-pole) P2R-087P (2-pole) 4.5±0.1 15±0.1 4±0.1 4±0.1 6±0.1 7±0.1 7.5 (8.1) 29.6 0.7 8.9 8.7 8.7 29.1 7.5 14 max. 37 max. 14 max. 37 max. 41 max. Mounting HolesTerminal Arrangement (Bottom View) Mounting HolesTerminal Arrangement (Bottom View) Eight, 1.3-dia. holes Five, 1.6-dia. holes 7.4 0.3 16.4 10.4 3.5 8.1 16.4 10.4 7.4 41 max. 3.5 8.75 4.5 38.0 P2R-@7P G2R-@-S (S) Relay P2R-@P Socket P2R-@A Socket G2R-@-S (S) Relay P2R-@7P Socket G2R-@-S (S) Relay P2R-@P P2R- @A 47.544.5
G2R-@-S (S) Mounting Tracks End Plate Spacer Mounting Plate P2R-P Safety Precautions Be sure to read the Common Precautions for All Relay in the website at the following URL: http://www.ia.omron.com/. Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets. Refer to PYF-@@-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets. Warning Indications
- Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
- Check that the test button is released before turning ON relay cir- cuits.
- If the test button is pulled out too forcefully, it may bypass the mo- mentary testing position and go straight into the locked position.
- Use an insulated tool when you operate the test button. PFP-100N, PFP-50N PFP-100N2 4.5 15 25 25 25 25 10 10 1,000 (500) 7.3±0.15 35±0.3 27±0.15 4.5 15 25 25 25 25 15 10 10 1,000 35±0.3 27 24 29.2 1 1.515 (5) It is recommended to use a panel 1.6 to 2.0 mm thick. PFP-M PFP-S 11.5 6.2 1.8 35.5 35.3 1.8 1.3 4.8 44.3 34.8 16.5M4 x 8 pan head screw 90 4.5 49 42±0.1 9±0.1 9±0.1 72±0.2 18±0.15 R2.25 10-&MMJQTFIPMF 13.6 4RVBSFIPMF 3.4 30.5 t=1.6 mm CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Cation
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.