© 2015 Bel Power Solutions, Inc. North America +1.866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353.61.225.977 tech.support@psbel.com BCD.00275_AB Three-Phase AC Input Suitable for 3U or 5U Height Mounting Single-Wire Current Share or Droop Current Share Remote Voltage Adjust and Current Monitoring Overtemperature, Overload and Overvoltage Protection LED Supply Status Indicators Current Share Control for up to 30 Units Standard & Customized Rack Adaptors Available Front Panel Selectable-Input-Range RoHS Compliant The FXP7000 Series of rack -mounted power systems provides AC front -end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The hot-pluggable FXP supplies do not include an output isolation diode and may be paralleled up to 210 kW of total output power. These supplies provide excellent protection against input voltage transients. Access to interfaces for remote sensing, remote voltage adjust, current sharing, current monitoring, power supply sta tus, standby voltage and inhibit, as well as power connections, is through a connector at the rear of the supply. The FXP has its fan, handles, voltage adjust, and indicator lights on the front panel and a single hot -plug connector on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positi ve or negative polarity supply. The FXP7000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480 VAC, delta or wye.
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB MODEL OUTPUT VOLTAGE INPUT VOLTAGE RANGE 3-PHASE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION 1 INITIAL SETTING ACCURACY FXP7000-48-SG 48 V 180 to 264 VAC or PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Input Voltage - AC 3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. 200 380 -10 240 480 +10 VAC VAC Input Current Per phase at full rated load. FXP7000 at 180 VAC: 30 Arms Inrush Surge Current 2 Internally limited. Vin = 264 VAC (one cycle). 25° C: Vin = 528 VAC (one cycle). 25° C: 38
38 Apk
Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at full power. 208 VAC:
400 VAC:
Operating Frequency Switching frequency, fixed. 100 kHz Power Factor 0.90 W/VA PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Output Voltage Adjustment Range An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. 45.6 50.4 V Output Power Continuous duty rating. 7000 Watts Output Current Continuous duty rating. 145 A Efficiency Full rated load (208 VAC). 88 91 % Regulation Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. 0.2 0.75 2.0 0.2 Ripple & Noise Measured at mating connector w/ 0.01μF + 10μF Tant. 20 MHz BW:
100 MHz BW: 1
2 % p-p Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Minimum Loads Minimum loading required to maintain regulation. 0 A Transient Response Max. recovery time, to within 1% of initial set point due to a 25% load change, 1A/μs. Time: Deviation: 800 3.2 μs Turn-On Delay Time required for initial output voltage stabilization after power-up. 3 s Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 100 ms 1 With Remote Sense connected.
2 The minimum time OFF between two turns ON of the unit needs to be > 30 seconds
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB PARAMETER 3, 4 DESCRIPTION/CONDITIONS MIN NOM MAX UNITS AC Power Fail Warning Warning provided prior to Vout dropping 5% after loss of AC input. 4 ms Auxiliary Power Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. 11.6 12.0 12.4 V Output current. 500 mA Current Monitor Monitor output current over a compliance range of 0~10 V. Normal output: Total error current: 0.5 0.10 0.5 mA/A mA Current Share Static sharing deviation as a percent of full-load rating for loads >10%. Active: Passive: Input Range Select Status Maximum signal resistance in high input voltage range selection. 0.10 Ω Loss of Phase Warning Warning provided prior to protective reduction in current limit. 500 ms Output Inhibit 5 Voltage required to enable supply (0.5 mA sink). 1.0 V Output Interlock 5 Voltage required to enable supply (6 mA sink). 1.0 V Output Overload Protection Straight line current limit (above approx. 5 V Vout). 149 156 A Output Overload Warning Signal level on overload. 2.2 V Output Short Circuit Protection Occurs on overload when Vout is below approx. 5 V. May operate in burst-mode. Iavg: A Output Voltage Fault Signal Deviation from adjusted Vout that is considered as a fault. ±3 ±4 ±5 % Output Voltage Margin Output voltage swing available through Margin pin (analog). ±4.8 ±5.0 ±5.2 % Overtemperature / Fan Failure Warning Time between fault warning and shutdown. Latching shutdown. 100 ms Overvoltage Protection Latch style overvoltage protection. 55.2 57.6 60.0 V Power Supply Present Signal Resistance to logic ground upon insertion of supply. 1000 Ω Remote Sense Maximum load lead loss compensation (round trip). 1.0 V PARAMETER DESCRIPTION / CONDITIONS MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1. CE marked for the Low Voltage Directive. Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. A A Class ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 4. ±4 kV Input Transient Protection Per EN61000-4-5. Line-to-Line: Line-to-Ground: 3 kV Voltage Sag Immunity Per SEMI F47-0200 FXC/FXP7000 Pending Leakage Current Per UL60950 and EN60950: FXP7000 at 240 VAC, 60 Hz: FXP7000 at 400 VAC, 50 Hz: FXP7000 at 480 VAC, 60 Hz: mA 3 All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40mA sink capability, and a 100k pull-up to 5V. 4 In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature / fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED’s indicating output loading. 5 Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details.
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Altitude Operating. Non-Operating. 10k 40k ASL Ft. Operating Temperature At 100% load: At 50% load: 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15-minute warm-up). .02 %/°C Relative Humidity Non-Condensing. 95 %RH Shock Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis +20 +40 Gpk Vibration Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02îDA, 32-2000 Hz Non-operating: random 10-2000 Hz 1 6.15 Gpk Grms Airflow Airflow provided through the supply from front to rear. 155 4.4 555 2.8 cfm m3/min Ifm m/s PARAMETER DESCRIPTION / CONDITIONS MIN NOM MAX UNITS Weight 13 kg (29 lb) Figure 1 - Rear and Front Views for FX76000 FRONT VIEW 5.000" (127m m ) 4 80VAC 4.552" (115.62m m ) 0.222" (5.64m m ) C C Tyco PN Elcon PN Description 1648601-1 296-22-01100 CONN HSING FEM 52P TOP DRAWER 1648420-1 712-12-01107 CONTACT SOCKET #0 DOUBLE CROWN 1648318-1 702-32-01107 CONN SOCKET #12 BLIND MATE 1648325-1 702-92-01109 CONN SOCKET #20 BLIND MATE INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC INPUT VOLTAGE DISPLAY CU TOUT 0.090" (2.29m m ) 2PL LOCK HANDLE RELEASE CENTER -TO- CENTER 0.226" (5.74m m ) REAR VIEW 3.901" (99.09m m ) 2.437" (61.90m m ) 0.521" (13.24m m ) MATING CONNECTOR INFORMATION LL
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB Figure 2 – FXC7000 Overall Size 16.09" (408.7mm) 14.259" (362.18mm) 4.954" (125.83mm) 0.87" (22.1mm) LED HANDLE 8.00" (203.2mm) 0.341" (8.66mm) 0.204" (5.18mm) NOTE: TOTAL BOTTOM STACKUP OF RACK MU ST BE NO GRE ATER THAN 0.204". FOR OPTIONAL HARD MOUNTING, USE M4 X 0.7 SCREWS, 8PL (MARKED A) ON SIDE OR B OTTOM WITH MAXIMUM PENETRATION 3.8mm. RECOMMENDED MOUNTING TORQUE 10.5 INCH LB S. (0.64N/M) MAIN TAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR ) FOR AIR COOLING A 5.750" (146.05mm) A 1.100" (27.94mm) 0.480" (12.19mm) A 4.000" (101.6mm) A 7.509" (190.73mm) A A (297.28mm) A A 11.704" 0.649" (16.48mm) 0.590" (14.99mm) LOCK HANDLEA <--AIRFLOW SIDE VIEW A LOCK HOOK 16.96" (430.8mm) A BOTTOM VIEW A A A A A 1.759" (44.68mm) 15.462" (392.73mm)
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB NOTE: The FRH7000G Power Shelf is designed for alternative vertical mounting with the right side down. NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY. 19.000" (482.6mm) 18.312" (465.12mm) FXP 0007 2PL 5.215" (132.46mm) 1.484" 2PL (37.69mm) 0.129" 4PL (3.28mm) 2.250" 2PL (57.15mm)
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB (Used with FRH7000G Power Shelf) This kit is used to cover an unused right-side slot of the FRH7000G Power Shelf (as viewed from the front of the FRH7000G). The kit can be installed before, or after installation of the power shelf into the rack. BRACKET, 2 PLACES FILLER PANEL (FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF)
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY. 8.70" (221.0mm) 7.184"2PL (182.47mm) INPUT VOLTAGE DISPLAY CU TOUT INPUT VOLTAGE RANGE SELECT MODULE 1.434" 2PL (36.42mm) 480VAC 0.000 480VAC480VAC R 0.129" 4PL (3.28mm)
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00275_AB (Used with FRV7000G Power Shelf) This kit is used to cover an unused left or center slot of the FRV7000G Power Shelf (as viewed from the front of the FRV7000G). One kit is required per slot. Kits can be installed before, or after installation of the power shelf into the rack. UPPER BRACKET LOWER BRACKET (FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF) FILLER PANEL NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.