DESCRIPTION

The FSG Series Force Sensor provides precise, reliable force sensing performance in a compact commercial -grade package. The sensor features a proven sensing technology that utilizes a specialized piezoresistive micro-machined silicon sensing element. The low power, unamplified, non - compensated Wheatstone bridge circuit design provides inherently stable mV outputs over the 5 N, 10 N, 15 N and 20 N force ranges. Force sensors operate on the principle that the resistance of silicon-implanted piezoresistors will increase when the resistors flex under any applied force. The sensor concentrates force from the application, through the stainless steel plunger, directly to the silicon-sensing element. The amount of resistance changes in proportion to the amount of force being applied. This change in circuit resistance results in a corresponding mV output level change. The sensor package design incorporates patented modular construction. The use of innovative elastomeric technology and engineered molded plastics results in overforce capacities of up to three times the rated force. The stainless steel plunger provides excellent mechanical stability and is adaptable to a variety of applications. Various electric interconnects can accept prewired connectors, printed circuit board mounting, and surface mounting. The unique sensor design also provides a variety of mounting options that include mounting brackets. FEATURES AND BENEFITS  Extremely low deflection (approx. 30 µm typical at Full Scale) helps reduce measurement error  Low repeatability error (0.2% span) improves overall system accuracy  Low linearity error (0.5% span) improves system accuracy over the entire force range  Low off-center loading errors improves system accuracy due to mechanical misalignment  Resolution to 0.0098 N improves customer’s system accuracy  Fast response time allows system to make faster decisions which may improve system accuracy  Low power consumption allows use in battery applications  High ESD resistance of 8 kV) reduces special handling during assembly POTENTIAL APPLICATIONS Medical  Infusion pumps  Ambulatory non-invasive pumps  Occlusion detection  Kidney dialysis machines  Enteral pumps Industrial  Load and compression sensing  Variable tension control  Robotic end-effectors  Wire bonding equipment

Table 1. Performance Characteristics (At 10 ±0.01 Vdc, 25 °C [77 °F].)1

  1. All force-related specifications are established using dead weight or compliant force.
  2. The range of voltage excitation which can be supplied to the product to produce an output which is

partial temperature compensation of span.

  1. The output signal obtained when the zero force is applied to the sensor. Also known as "null" or "zero".
  2. The change in the null resulting from a change in temperature .It is not a predictable error as it can shift
  3. The algebraic difference between output signals measured at the upper and lower limits of the operating

force range. Also known as "full scale output" or simply "span".

  1. The maximum deviation of product output from a straight line fitted to output measured over the operating

deviations of each of the points from the straight line.

  1. The ratio of output signal change to the corresponding input force change. Sensitivity is determined by
  2. The maximum deviation in sensitivity due to changes in temperature over the operating temperature

range, relative to sensitivity measured at 25 °C.

  1. The maximum difference between output readings when the same force is applied consecutively, under
  2. The maximum force which may safely be applied to the product for it to remain in specification once

Table 2. Environmental Specifications

  1. The temperature range over which the product may safely be exposed without excitation or force applied. Under these conditions the

permanent damage to the product.

  1. MCTF is a basic measure of reliability for a non -repairable device. It is the mean number of cycles to maximum operating force over which

based upon test data. MCTF may vary depending on the specific application in which a sensor is utilized.

1985 Douglas Drive North

Golden Valley, MN 55422 sensing.honeywell.com 008028-2-EN February 2013 © 2013 Honeywell International Inc. All rights reserved. Order Guide Catalog Listing Description FSG005WNPB FSG Series Force Sensor, 0 N to 5 N force sensing range, blister pack packaging FSG010WNPB FSG Series Force Sensor, 0 N to 10 N force sensing range, blister pack packaging FSG015WNPB FSG Series Force Sensor, 0 N to 15 N force sensing range, blister pack packaging FSG020WNPB FSG Series Force Sensor, 0 N to 20 N force sensing range, blister pack packaging PC15132 Plastic mounting bracket WARNING MISUSE OF DOCUMENTATION  The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.  Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: sensing.honeywell.com Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax