Features
■Screw-in adaptor with process connection G1/4" male thread included in delivery ■Sensor housing material 1.4404 (316L) ■Medium contact material 1.4571 (316Ti) ■Immersion depth 16.9 mm ■Process value display with bar graph ■Flow monitoring for liquid media ■Protection classes IP66, IP67 and IP69K ■Adjustment of flow speed via teach function ■10…33 VDC ■NO/NC contact, PNP/NPN output, IO-Link ■Connector, M12 × 1 Wiring diagram Functional principle The flow sensor functions according to the calorimetric principle. The distinctive feature of this principle is that the flow rate correlates directly to the thermal loss of energy in the probe. The increased loss of energy is
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|5 FS100-300L-04-2UPN8-H1141 | 11/07/2023 23-44 | technical changes reserved Technical data Temperature monitoring Measuring range -25…85 °C Switching point accuracy ± 2 K; for water >3 cm/s Reproducibility ≤ 0.5 K Resolution 0.5 K Response time T09 12 s Response time T05 3 s Electrical data Operating voltage 10…33 VDC Short-circuit/reverse polarity protection yes / Cyclic / yes Power consumption ≤ 1.6 W, Typ. 1.3 W Voltage drop ≤ 1.8 VDC Continuous current carrying capacity of the DC switching output 250 mA Overload protection Yes Insulation class III Standby delay time 18…30 s Outputs Output 1 Flow: Switching output or IO-Link Output 2 Temperature: Switching output Communication protocol IO-Link Output function NO/NC programmable, PNP/NPN IO-Link IO-Link specification V 1.1 IO-Link port type Class A Transmission physics COM 2 (38.4 kBaud) Frame type 2.2 Included in the SIDI GSDML Yes Programming Programming options Automatic switching logic recognition, easy switching pointadjustment via touchpads Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L)/Grilamid TR90 UV Adapter material Stainless steel 1.4571 (316Ti) Materials (contact with media) Stainless steel 1.4571 (AISI 316Ti), FKM O-ring, AFM flat seal Process connection G 1/4'' male thread Process connection sensor M18 x 1.5 female thread therefore a direct measure of an increased flow rate.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|5 FS100-300L-04-2UPN8-H1141 | 11/07/2023 23-44 | technical changes reserved Technical data Process connection adapter M18 × 1.5 male thread; G 1/4'' male thread Electrical connection Connector, M12 × 1 Protection class IP66 IP67 IP69K Electromagnetic compatibility (EMC) DIN EN 60947-5-9: 2007 Environmental conditions Ambient temperature -40…+85 °C Storage temperature -40…+80 °C Shock resistance 50 g (11 ms) EN 60068-2-27 Vibration resistance 20 G (55…2000 Hz)DIN EN 60068-2-6 Tests/approvals Approvals CE cULus UL registration number E516036 Display LED display functions for status of supply voltage, switching states and teach processes. Process indicators via bar graph. MTTF 120 years acc. to SN 29500 (Ed. 99) 40 Mounting instructions
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|5 FS100-300L-04-2UPN8-H1141 | 11/07/2023 23-44 | technical changes reserved Product features FLOW and TEMP LEDs Two LED displays which are visible from almost all directions indicate the status of the outputs and the active teach mode. Process value display The generous 11-segment bicolor LED bar displays either the flow or temperature values in an easy-to-read manner. Label The translucent front cap and the metal housing are scratch-resistant and are inscribed in a con trasting color using a laser. Alignment The sensor head can be freely rotated within a range of 340°, simplifying the alignment of the electrical connection and user interface follow ing installation. Inclined display The user interface is tilted by 45°, offering a high level of comfort when operating and reading values. Status LEDs Additional LED displays provide information about the status of the power supply, faults and the locking function and—if available—IO-Link communication. Translucent front cap The front cap is made from scratch-resistant, temperature-resistant, translucent plastic. MODE, ENTER and SET Touch pads allow menus to be navigated reli ably — without wear and tear and with no need for additional sealing. Modular Concept The portfolio exhibits a variable and modular mechanical concept. The neutral M18 coupling nut on the sensor and the various screw-in adapters allow a variable process connection based on the usage requirements. Fast and flexible thanks to using neutral stock and spare parts as required. Temperature measurement Based on the calorimetric principle, the sensor also offers the option, in addition to monitoring the flow rate, of measuring the medium temperature. If in addition to the flow rate the medium temperature is also important, both process variables can be determined and evaluated independently of each other. DeltaFlow The implemented DeltaFlow monitoring supports error-free teaching by only enabling all teach processes once the flow rate to be monitored has settled at a constant level. Auto Detection PNP/NPN The automatic setting of the sensor output signal supports error-free configuration of the sensor on connection to the remote IO environment. The sensor automatically activates the output type that corresponds to the signal type of the input card connected. This function is activated by default and can also be configured specifically as required. Programmable NO/NC The switching outputs can optionally be used as normally open or normally closed. If the sensors have more than one switching output, these can be configured differently. Each switching output is configured as normally open by default. Back to pre- and factory settings Both Back to functions offer the option of resetting the current settings. Back to Pre- Settings replaces the current settings with the previous settings. Back to Factory Settings resets the sensor to the factory settings. Lock function (Loc/unLoc) The touch buttons can be locked/unlocked. When the key lock is activated, a teach-in process cannot be initiated. This prevents parameters from being modified accidentally, for example. Teach functions (Quick and MAX/MIN) Quick Teach allows quick teaching in of the switchpoint without teaching in a separate MAX/MIN range. With MAX/MIN Teach on the other hand, the flow range to be monitored is scaled to two limit values to be taught and the switchpoint is set within these two limits. Sensors with a switching output have both modes, whereas sensors without a switching output only have MAX/MIN Teach.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 5|5 FS100-300L-04-2UPN8-H1141 | 11/07/2023 23-44 | technical changes reserved LED display LED Color Status Description PWR Green On Operating voltage applied Device is operational Flashing Operating voltage applied IO-Link communication active (inverted flash with T on 900 ms and T off 100 ms) FLT Red On Error displayed (for error pattern in combination with LEDs see manual) Off No errors displayed LOC Yellow On Device locked Off Device unlocked Flashing Locking/unlocking process active FLOW Yellow On NO: Flow switchpoint exceeded (output "high") NC: Flow below minimum switchpoint (output "high") Off NO: Flow below minimum switchpoint (output "low") NC: Flow switchpoint exceeded (output "low") Flashing Teach mode/display of diagnostic data (see manual for specification) TEMP Yellow On NO: Temperature switchpoint exceeded (output "high") NC: Temperature below minimum switchpoint (output "high") Off NO: Temperature below minimum switchpoint (output "low") NC: Temperature switchpoint exceeded (output "low") Flashing Teach mode/display of diagnostic data (see manual for specification) For detailed description of the display patterns and flashing codes, see manual D100002084 IO-Link process data image Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Byte n 14 Bit Process Value (TEMP) State Out 2 (TEMP) State Out 1 (FLOW) Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Byte n+1 16 Bit Process Value (FLOW)