0713 B U -SB 13730 Page 1 of 3 D ata Sheet # 1019

FU SETR O N ™ 25 0V C lass R K 5 FR N - R — 25 0Vac/125 Vdc, 1⁄10 - 60A, D ual Elem ent, Tim e- D elay Fuses D escription: A dvanced protection, energy efficient C lass R K5 dual elem ent, current-lim iting, tim e-delay fuses w ith optional open fuse indication on select ratings. Tim e-delay – 1 0 seconds (m inim um ) at 500% of rated current (8 seconds for 1 ⁄1 0 -30A sizes). C atalog Sym bol: F R N -R -(am p) (non-indicating) F R N -R -(am p)ID (indicating) R atings: Volts — 2 50Vac, 1 2 5Vdc A m ps — 1 ⁄1 0 -60 A m ps IR — 2 00kA Vac R M S Sym . — 2 0kA Vdc Agency Inform ation: C E , U L Listed, Std. 2 4 8-1 2 , C lass R K-5, G uide JDDZ, F ile E 4 2 73 C SA C ertified, C 2 2 .2 N o. 2 4 8.1 2 , C lass 1 4 2 2 -02 , F ile 53787 C atalog N um bers (am ps) — N on- indictaing fuses F R N -R - 1 ⁄1 0 F R N -R -1 8⁄1 0 F R N -R -8* F R N -R - 1 ⁄8 F R N -R -2 F R N -R -9 * F R N -R - 15⁄1 00 F R N -R -2 1 ⁄4 F R N -R -1 0* F R N -R - 2 ⁄1 0 F R N -R -2 1 ⁄2 F R N -R -1 2 * F R N -R - 1 ⁄4 F R N -R -2 8⁄1 0 F R N -R -1 5* F R N -R - 3⁄1 0 F R N -R -3 F R N -R -1 7 1 ⁄2 * F R N -R - 4 ⁄1 0 F R N -R -3 2 ⁄1 0 F R N -R -2 0* F R N -R - 1 ⁄2 F R N -R -3 1 ⁄2 F R N -R -2 5* F R N -R - 6⁄1 0 F R N -R -4 F R N -R -30* F R N -R - 8⁄1 0 F R N -R -4 1 ⁄2 F R N -R -35* F R N -R -1 F R N -R -5 F R N -R -4 0* F R N -R -1 1 ⁄8 F R N -R -5 6⁄1 0 F R N -R -4 5* F R N -R -1 1 ⁄4 F R N -R -6 F R N -R -50* F R N -R -1 4 ⁄1 0 F R N -R -6 1 ⁄4 F R N -R -60* F R N -R -1 1 ⁄2 F R N -R -7 F R N -R -1 6⁄1 0 F R N -R -7 1 ⁄2 * O pen fuse indication available by inserting the sufix “ID.” E .g., F R N -R -1 5 ID . C arton Q uantity and W eight Am p R ating C arton Q ty. 1 ⁄1 0 –1 5 1 0 1 7 1 ⁄2 –30 1 0 35–60 1 0 D im ensions - in Features:

  • Provides m otor overload, ground fault and short-circuit protection
  • H elps protect m otors against burnout from overloads
  • H elps protect m otors against burnout from single-phasing on three-phase system s
  • Sim plifies and im proves blackout prevention (selective coordination)
  • Dual-elem ent fuses can be applied in circuits subject to tem porary m otor overloads and surge currents to provide both high perform ance short-circuit and overload protection
  • The overload elem ent provides protection against low level overcurrent of overloads and w ill hold an overload w hich is five tim es greater than the am pere rating of the fuse for a m inim um of ten seconds. R ecom m ended Fuse Blocks Fuse Am ps 1- Pole 2- Pole 3- Pole 0-30 H 2 5030-1 H 2 5030-2 H 2 5030-3 R 2 5030-1 R 2 5030-2 R 2 5030-3 35-60 H 2 5060-1 H 2 5060-2 H 2 5060-3 R 2 5060-1 R 2 5060-2 R 2 5060-3 F or additional inform ation on the 2 50 volt fuse blocks, see Data Sheets # 1 1 1 0 (R 2 50), # 1 1 1 2 (H 2 50). Fuse R educers For C lass R Fuses Equipm ent D esired Fuse C atalog N um bers Fuse C lips (C ase) Size (Pairs) 25 0V 60A 30A N O .2 63-R 1 00A 30A N O .2 1 3-R 60A N O .2 1 6-R 2 00A 60A N O .2 2 6-R F or additional inform ation on C lass R fuse reducers, see Data Sheet # 1 1 1 8. 0.56" (±0.008) (± 0.31) 1/10 to 30A 35 to 60A 0.81" (±0.008) (± 0.31)

0713 B U -SB 13730 Page 2 of 3 D ata Sheet # 1019

FU SETR O N ™ 25 0V C lass R K 5 Tim e- C urrent C urves - Average M elt 1⁄10 to 6 1⁄4 Am ps AMP RATING CURRENT IN AMPS TIME IN SECONDS FR N - R — 25 0Vac/125 Vdc, 1⁄10 - 60A, D ual Elem ent, Tim e- D elay Fuses

0713 B U -SB 13730 Page 3 of 3 D ata Sheet # 1019

FU SETR O N ™ 25 0V C lass R K 5 The only controlled copy of this D ata Sheet is the electronic read-only version located on the Cooper Bussm ann N etw ork D rive. All other copies of this docum ent are by definition uncontrolled. This bulletin is intended to clearly present com prehensive product data and provide technical inform ation that w ill help the end user w ith design applications. Cooper Bussm ann reserves the right, w ithout notice, to change design or construction of any products and to discontinue or lim it distribution of any products. C ooper Bussm ann also reserves the right to change or update, w ithout notice, any technical inform ation contained in this bulletin. O nce a product has been selected, it should be tested by the user in all possible applications. C urrent- Lim itation C urves Tim e- C urrent C urves - Average M elt 8 to 60 Am ps 400000 9000 8000 7000 7000 6000 6000 300000 200000 100000 5000 4000 4000 90000 3000 2000 1000 3000 70000 80000 70000 60000 B A 50000 60000 200000 20000 2000 40000 100000 50000 10000 5000 1000 30000 90000 80000 40000 9000 8000 30000 20000 10000 30A 60A AMP RATING INS TAN TANEOUS PEAK LE T-THROUGH CURREN T IN AMPS PROSPECTIVE SHO RT-CIRCUIT CURREN T - SYMMETRICA L RMS AMPS FR N - R — 25 0Vac/125 Vdc, 1⁄10 - 60A, D ual Elem ent, Tim e- D elay Fuses The only controlled copy of this D ata Sheet is the electronic read-only version located on the Cooper Bussm ann N etw ork D rive. All other copies of this docum ent are by definition uncontrolled. This bulletin is intended to clearly present com prehensive product data and provide technical inform ation that w ill help the end user w ith design applications. Cooper Bussm ann reserves the right, w ithout notice, to change design or construction of any products and to discontinue or lim it distribution of any products. C ooper Bussm ann also reserves the right to change or update, w ithout notice, any technical inform ation contained in this bulletin. O nce a product has been selected, it should be tested by the user in all possible applications. AMP RATING CURRENT IN AMPS TIME IN SECONDS 810 15 30 60 C urrent- Lim iting Effects Prosp. Let-Through Current S.C.C. (Apparent RM S Sym m etrical Vs. Fuse Rating) 30A 60A 5000 1000 2000 10,000 2000 3000 15,000 2000 3000 20,000 2000 4000 25,000 2000 4000 30,000 2000 4000 35,000 2000 4000 40,000 2000 5000 50,000 3000 5000 60,000 3000 5000 70,000 3000 6000 80,000 3000 6000 90,000 3000 6000 100,000 3000 6000 150,000 4000 7000 200,000 4000 8000