belfuse.com/power-solutions PRELIMINARY FRH100-00 DC-DC Converter Input Filter RoHS Compliant Bel Power Solutions FRH100-00 Input Filter helps control EMC immunity and emission in board-level DC-DC converter applications, minimizing the conducted and radiated emissions generated by switch mode DC-DC converters. The FRH100-00 allows board designs utilizing DC-DC converters to meet stringent EMC requirements according to railway industry standards. Key Features & Benefits

  • Ultra-Wide input voltage range: 14 -160 VDC
  • Maximum operating current 8 A
  • Operating ambient temperature range -40 °C to +105 °C
  • Small footprint
  • Meet IEC/EN 61000-4 series standards and CISPR16 / EN 55032
  • Meet railway industry EN 50155 / EN 50121-3-2 and AREMA standards

Applications

  • Railway related equipment

tech.support@psbel.com belfuse.com/power-solutions FRH100-00 PRELIMINARY 1. MODEL SELECTION PART NUMBER INPUT VOLTAGE RANGE [VDC] RATED CURRENT [A] FRH100-00 14 – 160 8 2. INPUT SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN. TYP. MAX. UNIT Input Voltage Range Operating temperature range 14 110 160 VDC 3. OUTPUT SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN TYP. MAX. UNIT Efficiency 25 °C, 24 VDC @ 100 W 96 98 – % Operating Current 1 – – 8 A Transient Maximum Current 10 s – – 10 A 1 For operating current please refer to temperature derating curves. 4. GENERAL SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN TYP. MAX. UNIT Operating Temperature -40 – 105 °C Storage Temperature -55 – 125 °C Storage Humidity 5 – 95 %RH Withstand voltage +Vin~ , -Vin~ , electric strength test for 1 minute with a leakage current of 5 mA max 2100 – – VAC MTBF MIL-HDBK-217F @ 25 °C 1000 – – kh 5. MECHANICAL SPECIFICATIONS PARAMETER DESCRIPTION Case Material Black plastic; flame-retardant and heat-resistant (UL94 V-0) Dimension 67.0 x 37.0 x 19.8 mm Weight 100 g (Typ.)

Asia-Pacific Europe, Middle East North America +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2021 Bel Power Solutions & Protection BCD.01090_2 PRELIMINARY 6. ELECTROMAGNETIC COMPATIBILITY (EN50121-3-2) PARAMETER DESCRIPTION CLASS / CRITERIA Emission 1 CE EN 55016-2-1 150 kHz – 500 kHz; 79 dBuV (see Fig. 3 for recommended circuit) 500 kHz – 30 MHz; 73 dBuV (see Fig. 3 for recommended circuit) RE CISPR16-2-3 30 MHz – 230 MHz ; 40 dBuV/m at 10 m (see Fig. 3 for recommended circuit) 230 MHz – 6 GHz; 47 dBuV/m at 10 m (see Fig. 3 for recommended circuit) Immunity ESD EN 61000-4-2 Contact ±6 kV/Air ±8 kV perf. Criteria A RS EN 61000-4-3 80 – 800 MHz; 20 V/m 800 – 1000 MHz; 20 V/m 1400 – 2000 MHz; 10 V/m 2000 – 2700 MHz; 5 V/m 5100 – 6000 MHz; 3 V/m perf. Criteria A EFT EN 61000-4-4 ±2 kV; 5/50 ns; 5 kHz (see Fig. 3 for recommended circuit) perf. Criteria A Surge EN 61000-4-5 Line to line ±1 kV (42 Ω, 0.5 μF), line to ground ± 2 kV (42 Ω, 0.5 μF) (see Fig. 3 for recommended circuit) Line to line ±1 kV (2 Ω, 18 μF) line to ground ±2 kV (12 Ω, 9 μF) (see Fig. 3 for recommended circuit) perf. Criteria A CS EN 61000-4-6 0.15 MHz – 80 MHz 10 V r.m.s perf. Criteria A

1 Corresponds or exceeds EN 50121-3-2

  1. ELECTROMAGNETIC COMPATIBILITY (AREMA) PARAMETER DESCRIPTION CLASS / CRITERIA Emissions CE CISPR16-2-1 CISPR16-1-2 150 kHz – 500 kHz; 79 dBuV (see Fig. 3 for recommended circuit) 500 kHz – 30 MHz; 73 dBuV (see Fig. 3 for recommended circuit) CLASS A RE CISPR16-2-3 30 MHz – 230 MHz; 40 dBuV/m at 10 m (see Fig. 3 for recommended circuit) 230 MHz – 1 GHz; 47 dBuV/m at 10 m (see Fig. 3 for recommended circuit) CLASS A Immunity ESD IEC 61000-4-2 Contact ±6 kV/Air ± 8 kV perf. Criteria A RS IEC 61000-4-3 80 – 1000 MHz; 10 V/m 160 – 165 MHz; 20 V/m 450 – 470 MHz; 20 V/m 800 – 960 MHz; 20 V/m 1400 – 2000 MHz; 20 V/m 2100 – 2500 MHz; 5 V/m perf. Criteria A EFT IEC 61000-4-4 ±2 kV 5/50 ns; 5 kHz (see Fig. 3 for recommended circuit) perf. Criteria A Surge IEC 61000-4-5 Line to line ±2 kV (2 Ω, 18 μF); line to ground ±2 kV (2 Ω, 18 μF) (see Fig. 3 for recommended circuit) perf. Criteria A CS IEC 61000-4-6 0.15 MHz-80 MHz; 10 V r.m.s perf. Criteria A MS IEC 61000-4-8 IEC 61000-4-8 60 Hz; 100 A/m (see Fig. 3 for recommended circuit) 60 Hz; 300 A/m (see Fig. 3 for recommended circuit) perf. Criteria A

Asia-Pacific Europe, Middle East North America +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2021 Bel Power Solutions & Protection BCD.01090_2 PRELIMINARY COMPONENTS VALUE RECOMMENDED COMPONENT C1 1 µF CERAMIC; 1 µF; 10%; 100 V; X7R; 1206; -55 to +125°C C2 330 µF ELECTROLYTIC; Al,WET; RADIAL; 330 µF; 20%; 63 V; Ø10 x 20 mm; PITCH 5 mm; -40 to +105°C C4 330 µF ELECTROLYTIC; Al,WET; RADIAL; 330 μF; 20%; 200 V; Ø 18 x 30 mm; PITCH 7.5 mm; -40 to +105°C CY4 1 nF CERAMIC; X1/Y1; 1 nF; 10%; 400 V; PITCH 10 mm; -40 to+125°C CY5, CY6 2.2 nF CERAMIC; X1/Y1; 2.2 nF; 10%; 400 V; PITCH 10 mm; -40 to+125°C D1 20 A SCHOTTKY; DUAL; 200 V; 2x 20 A; Vf 0.95 V; TO220; -55 to +150°C; COMMON CATHODE Fuse or Breaker 15 A Type C 1 Type of fuse / circuit breaker can be selected according to the actual application. The specification value must be greater than the maximum input working current and less than the rated working current of the anti-reverse polarity diode. SURGE STANDARD COMPONENTS VALUE RECOMMENDED COMPONENT line to line ± 1 kV (42 Ω, 0.5 μF) line to ground ± 2 kV (42 Ω, 0.5 μF) C0 100 μF ELECTROLYTIC; Al,WET; RADIAL; 100 µF; 20%; 250 V; Ø 16 x 20 mm; PITCH 7.5 mm; -40 to +105°C C10, C11 — — line to line ± 1 kV (2 Ω, 18 μF) line to ground ± 2 kV (12 Ω, 9 μF) C0, C10 100 μF ELECTROLYTIC; Al,WET; RADIAL; 100 µF; 20%; 250 V; Ø 16 x 20 mm; PITCH 7.5 mm; -40 to +105°C C11 — — line to line ± 2 kV (2 Ω, 18 μF) line to ground ± 2 kV (2 Ω, 18 μF) C0, C10, C11 100 μF ELECTROLYTIC; Al,WET; RADIAL; 100 µF; 20%; 250 V; Ø 16 x 20 mm; PITCH 7.5 mm; -40 to +105°C

  1. MECHANICAL SPECIFICATIONS

Figure 4. Mechanical drawing ment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.