belfuse.com/power-solutions FRD6-00 DC-DC Converter Input Filter RoHS Compliant Bel Power Solutions FRD6-00 Input Filter helps control EMC immunity and emission in board-level DC-DC converter applications, minimizing the conducted and radiated emissions generated by switch mode DC-DC converters. The FRD6-00 allows board designs utilizing DC-DC converters to meet stringent EMC requirements according to railway industry standards. Key Features & Benefits
- Ultra-Wide input voltage range: 14 -160 VDC
- Maximum operating current 0.8 A
- Operating ambient temperature range -40 °C to +105 °C
- Small footprint
- Meet IEC/EN 61000-4 series standards and CISPR16 / EN 55032
- Meet railway industry EN 50155 / EN 50121-3-2 and AREMA standards
- In compliance with the latest revision of the safety standard IEC 62368-1
Applications
- Railway related equipment
1 Pending
tech.support@psbel.com belfuse.com/power-solutions FRD6-00 1. MODEL SELECTION PART NUMBER INPUT VOLTAGE RANGE [VDC] RATED CURRENT [A] FRD6-00 14 – 160 0.8 2. INPUT SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN. TYP. MAX. UNIT Input Voltage Range 14 110 160 VDC Transient Maximum Voltage 1 s – – 200 VDC 3. OUTPUT SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN TYP. MAX. UNIT Operating Current – – 0.8 A 4. GENERAL SPECIFICATIONS PARAMETER DESCRIPTION / CONDITIONS MIN TYP. MAX. UNIT Operating Temperature -40 – 105 °C Storage Temperature -55 – 125 °C Storage Humidity 5 – 95 %RH MTBF MIL-HDBK-217F @ 25 °C 1000 – – kh 5. MECHANICAL SPECIFICATIONS PARAMETER DESCRIPTION Case Material Black plastic; flame-retardant and heat-resistant (UL94 V-0) Dimension 31.60 x 20.30 x 12.50 mm Weight 10 g (Typ.)
Asia-Pacific Europe, Middle East North America +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.20210_1 13 September 2022 6. ELECTROMAGNETIC COMPATIBILITY (EN50121-3-2) PARAMETER DESCRIPTION CLASS / CRITERIA Emission 1 CE EN 55016-2-1 150 kHz – 500 kHz; 79 dBuV (see Fig. 1 for recommended circuit) 500 kHz – 30 MHz; 73 dBuV (see Fig. 1 for recommended circuit) RE CISPR16-2-3 30 MHz – 230 MHz ; 40 dBuV/m at 10 m (see Fig. 1 for recommended circuit) 230 MHz – 6 GHz; 47 dBuV/m at 10 m (see Fig. 1 for recommended circuit) Immunity ESD EN 61000-4-2 Contact ±6 kV/Air ±8 kV perf. Criteria A RS EN 61000-4-3 80 – 800 MHz; 20 V/m 800 – 1000 MHz; 20 V/m 1400 – 2000 MHz; 10 V/m 2000 – 2700 MHz; 5 V/m 5100 – 6000 MHz; 3 V/m perf. Criteria A EFT EN 61000-4-4 ±2 kV; 5/50 ns; 5 kHz (see Fig. 1 for recommended circuit) perf. Criteria A Surge EN 61000-4-5 Line to line ±1 kV (42 Ω, 0.5 μF) (see Fig. 1 for recommended circuit) Line to line ±1 kV (2 Ω, 18 μF) (see Fig. 1 for recommended circuit) perf. Criteria A CS EN 61000-4-6 0.15 MHz – 80 MHz 10 V r.m.s perf. Criteria A
1 Corresponds or exceeds EN 50121-3-2
- ELECTROMAGNETIC COMPATIBILITY (AREMA) PARAMETER DESCRIPTION CLASS / CRITERIA Emissions CE CISPR16-2-1 CISPR16-1-2 150 kHz – 500 kHz; 79 dBuV (see Fig. 1 for recommended circuit) 500 kHz – 30 MHz; 73 dBuV (see Fig. 1 for recommended circuit) CLASS A RE CISPR16-2-3 30 MHz – 230 MHz; 40 dBuV/m at 10 m (see Fig. 1 for recommended circuit) 230 MHz – 1 GHz; 47 dBuV/m at 10 m (see Fig. 1 for recommended circuit) CLASS A Immunity ESD IEC 61000-4-2 Contact ±6 kV/Air ± 8 kV perf. Criteria A RS IEC 61000-4-3 80 – 1000 MHz; 10 V/m 160 – 165 MHz; 20 V/m 450 – 470 MHz; 20 V/m 800 – 960 MHz; 20 V/m 1400 – 2000 MHz; 20 V/m 2100 – 2500 MHz; 5 V/m perf. Criteria A EFT IEC 61000-4-4 ±2 kV 5/50 ns; 5 kHz (see Fig. 1 for recommended circuit) perf. Criteria A Surge IEC 61000-4-5 Line to line ±2 kV (2 Ω, 18 μF) (see Fig. 1 for recommended circuit) perf. Criteria A CS IEC 61000-4-6 0.15 MHz-80 MHz; 10 V r.m.s perf. Criteria A MS IEC 61000-4-8 IEC 61000-4-8 60 Hz; 100 A/m (see Fig. 1 for recommended circuit) 60 Hz; 300 A/m (see Fig. 1 for recommended circuit) perf. Criteria A
Figure 1. Recommended EMC Filtering input current and below rated working current of reverse polarity diode.
- MECHANICAL SPECIFICATIONS
Figure 3. Mechanical drawing ment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.