FR151SG HY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

  • Fast switching for high efficiency
  • Low cost RoHS
  • Diffused junction COMPLIANT
  • Low reverse leakage current
  • Low forward voltage drop
  • High current capability
  • Meet UL flammability classification 94V-0 Mechanical Data
  • Case: JEDEC A-405 molded plastic
  • Polarity: Color band denotes cathode
  • Mounting position: Any Note: Products with logo are made byHY Electronic (Cayman) Limited. Maximum Ratings and Electrical Characteristics Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristics Symbol FR151SG FR152SG FR153SG FR154SG FR155SG FR156SG FR157SG Unit Maximum Repetitive Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 V Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V Maximum Average Forward Rectified Current @T A=75℃ I(AV) A Peak Forward Surge Current, 8.3mS Single Half Sine-Wave, Superimposed on Rated Load (JEDEC Method) Peak Forward Voltage at 1.0A DC VF V Peak Forward Voltage at 1.5A DC VF V Maximum DC Reverse Current @TJ=25℃ at Rated DC Blocking Voltage @TJ=100℃ Maximum Reverse Recovery Time (Note 1) Trr 250 nS Typical Junction Capacitance (Note2) CJ pF Typical Thermal Resistance Junction to Ambient RθJA ℃/W Operating Junction Temperature Range TJ ℃ Storage Temperature Range TSTG ℃ FR15*SG-A/T-00/99-00/01 Rev. 11, 18-May-2020 2. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC. 3.The typical data above is for reference only. 30 20 -55 to +150 -55 to +150 Notes: 1. Measured with IF=0.5A,IR=1A,IRR=0.25A IR 5.0 μA 100 150 500 www.hygroup.com.tw 1.3 Fast Recovery Glass Passivated Recitifiers Reverse Voltage - 50 to 1000 Volts Forward Current - 1.5 Amperes Pb Package Outline Dimensions in Inches (Millimeters) 1.5 IFSM 50 A 1.1 FR151SG THRU FR157SG All d ata sheet.com

Rating and Characteristic Curves FR151SG THRU FR157SG The curve above is for reference only. FR15*SG-A/T-00/99-00/01 Rev. 11, 18-May-2020 0.2 0.4 0.6 0.8 1.2 1.4 1.6 0 50 100 150 Fig. 1 - Forward Current Derating Curve Average Forward Current (A) Fig. 2 - Maximum Non-Repetitive Surge Current Number of Cycles at 60Hz Peak Forward Surge Current (A) 1 10 100 8.3mS Single Half-Sine-Wave (JEDEC METOD) Ambient Temperature (℃) Fig. 3 - Typical Junction Capacitance Capacitance (pF) 100 1 10 100 TJ=25°C,f=1MHz Reverse Voltage (V) FR151SG-FR154SG FR155SG-FR157SG 0.1 TJ=25°C Pulse Width 300uS 2%Duty Cycle Fig. 4 - Typical Forward Characteristics Instantaneous Forward Current (A) Instantaneous Forward Voltage (V) All d ata sheet.com

ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require- ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi- lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. All operating parameters, including typical paramet- ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY pers- onnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of HY. Product names and markings noted herein may be trademarks of their respective owners. Rev. 11, 18-May-2020 Disclaimer All d ata sheet.com