Creation Date : June 07, 2022 (GMT) FPS3000-24/P RoHS ! Images are for reference only and show exemplary products. ! This PDF document was created based on the data listed on the TDK Corporation website. ! All specifications are subject to change without notice. Copyright(c) TDK Corporation. All rights reserved. Sales Region Worldwide (except Japan) Series FPS Model FPS3000 Status Production Feature Options IEC inlet front connect type Option Lineup Please refer to here. Recommended EMC Filter Accessories Please refer to here. Brand TDK-Lambda

Electrical Characteristics

Input Voltage Range[AC] 85 to 265Vac Input Voltage Range[DC] Efficiency 86% Typ. Rated Output Voltage[DC] 24Vdc Output Voltage Range[DC] 21.5 to 29Vdc Maximum Output Current 40A Maximum Output Power 2880W Package Type & Size Package / Mounting Rack mount Industry Standard Size Width(W) 400mm Nom. (15.75in Nom.) Height(H) 44mm Nom. (1.73in Nom.) Depth(D) 351mm Nom. (13.82in Nom.) Weight 10kg Typ. (22.0lbs Typ.) Other Operating Temp. Range 0 to 70°C Cooling Forced air Safety Standard(Certified) EN60950-1 UL60950-1 Safety Standard(Conformed) Remarks This page only shows representative characteristics. Please refer to the technical data for detailed specifications and conditions.