FPS LITTELFUSE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Protection Relays & Controls © 2013 Littelfuse Protection Relays & Controls Littelfuse.com/fps PHASE CT PHASE CT GF CTPHASE CT FPS-CTUL1 FPS-OPI (Control Unit) (Operator Interface) Feeder Protection–Advanced FPS SERIES Feeder Protection System
Description
The FPS Feeder Protection System monitors voltage and current to provide a comprehensive package of 17 protective functions. The FPS is a modular system with integrated protection, breaker control, metering, and data-logging functions. Operator Interface (FPS-OPI) g Large, bright, 4 x 20 vacuum-fluorescent display g Display metered values g Access set points g Powered by Control Unit g Panel mount or attach directly to Control Unit g Remote mounting (1 .2 km or 4000 ft maximum loop length) g 1/2 DIN size g Hazardous-location certified Control Unit (FPS-CTU) g Current inputs—5-A or 1-A secondary phase current transformers g Voltage inputs—up to 600 V without PTs g Earth-leakage input—5-A or 1-A secondary or sensitive transformer g 8 digital inputs, 5 relay outputs, 1 analog input and output g 24-Vdc supply for OPI and RTD modules, and for digital inputs g IRIG-B time-code input g 1/2 DIN size, surface mount g RS-485 network communications (Standard) g DeviceNet™, Profibus®, or Ethernet communications available Phase Current T ransformers Phase CTs are required to detect phase currents. Ground-Fault Current T ransformer Zero-sequence current transformer detects ground-fault current. Available with 5-A and 30-A primary ratings for low-level pickup. MPS-RTD T emperature Input Module Optional module provides 8 inputs to connect Pt100, Ni100, Ni120, and Cu10 RTDs. SE-IP65CVR-M Cover Optional gasketed, transparent cover for limited access and IP65 protection for an Operator Interface Module. B C D Accessories A AccESSoRIES REquIREmEnt FPS-OPI-01-00 Recommended SE-IP65CVR-M Optional Phase CTs Required Ground-Fault CT Recommended MPS-RTD-01-00 Optional oRdERIng numbER communIcAtIonS FPS-CTU-01-00 RS-485 FPS-CTU-02-00 RS-485 & DeviceNet™ FPS-CTU-03-00 RS-485 & Profibus® FPS-CTU-04-00 RS-485 & Ethernet
Ordering Information
Simplified Circuit Diagram BA Rev: 4-A-050213 Based on Manual Rev 0
Protection Relays & Controls © 2013 Littelfuse Protection Relays & Controls Littelfuse.com/fps Feeder Protection–Advanced PHASE VOLTAGES FPS-CTU CONTROL UNIT RELA Y OUTPUTS I/0 MODULE DIGITAL INPUTS 4-20 mA ANALOG INPUT ANALOG OUTPUT 4-20 mA 39 40 53 52 CONTROL POWER RS-485 30 29 27 26 23 22 PHASE CURRENT TRANFORMERS GROUND-FAULT CURRENT TRANSFORMER OPERATOR INTERFACE FPS-OPI (recommended)(required) (recommended) RTD MODULE MPS-RTD (optional) Wiring Diagram A B C Specifications Protective Functions (IEEE Device Numbers) Input Voltage 65-265 Vac, 25 VA; 80-275 Vdc, 25 W Power-Up Time 800 ms at 120 Vac Ride-Through Time 100 ms minimum 24-Vdc Source 100 mA maximum AC Measurements True RMS and DFT, Peak, 16 samples/cycle, and positive and negative sequence of fundamental Frequency 50 or 60 Hz Inputs Phase current, Earth-leakage current, Phase voltage, 7 digital, 1 analog Output Contacts 5 contacts — See Product Manual Approvals CSA certified, C-Tick ( Australian) Communications Allen-Bradley ® DFI and Modbus ® RTU (Standard); DeviceNet™, Profibus ®, Ethernet (Optional) Conformal Coating Standard feature Warranty 10 years Mounting: Control Unit Surface Operator Interface Panel, Control-Unit mounted Overload (49, 51) Phase reverse (current) (46) Overfrequency (81) Overcurrent (50, 51) Underfrequency (81) Ground fault (50G/N, 51G/N) Unbalance (voltage) (47) RTD temperature (38, 49) Unbalance (current) (46) Phase loss (voltage) (47) Overvoltage (59) Phase loss (current) (46) Undervoltage (27) Phase reverse (voltage) (47) Power factor (55) Features & Benefits FEAtuRES IEEE # bEnEFItS Overload 49, 51 Long-time overcurrent provides thermal protection for feeder or load Inverse-time overcurrent 50, 51 Coordination using IEEE and IEC Curves Definite-time overcurrent 50, 51 Instantaneous overcurrent to detect catastrophic failure Current unbalance/ Phase loss/Phase reverse 46 Detects an open or high-impedance phase Ground fault 50G/N, 51G/N Inverse and definite time. Early insulation-failure detection. RTD temperature 38, 49 Optional protection (MPS-RTD module) for load-temperature monitoring Overvoltage 59 Limits stress to insulation Undervoltage 27 Detects a damaging brown-out condition Voltage unbalance 47 Detects unhealthy supply voltage Two setting groups Minimizes Arc-Flash hazards during maintenance Breaker control Allows local and remote operation; reduces component count Metering Displays the measured and calculated parameters Data logging On-board 64-event recorder helps with system diagnosis Communications Remotely view measured values, event records, & reset trips Conformal coating Internal circuits are conformally coated to protect against corrosion and moisture FPS SERIES Feeder Protection System Rev: 4-A-050213 Based on Manual Rev 0