Features

U AC Line-Voltage or DC Powered U Display and/or Control: µS, mS, PPM or PPB (TDS), kΩ, MΩ, % Rejection, Difference, Ratio, °C or °F U 3 Fully Scalable 4 to 20 mA Outputs U Up to 4 Programmable Relays U Time Delay Relay Function U Proportional Pulse Control Capability U Meets USP Requirements U Programmable Temperature Compensation U Output Simulation for Complete System Testing U Simple Push-Button Operation U 1⁄4 DIN, NEMA 4X (IP65) Enclosure with Self-Healing Window Application U RO/DI System Control U Demineralizer Regeneration and Rinse U Scrubber, Cooling Tower and Boiler Protection U Chemical Concentration U Rinse Tank Water Quality U Desalinization U Leak Detection U Aquatic Animal Life Support Systems U Aquaculture U Environmental Studies Installation U Front Panel provides NEMA 4X (IP65) protection U Standard 1⁄4 DIN panel cutout U 102 mm (4") mounting depth U Optional NEMA 4X (IP65) rear cover kit with knockout ports for cable access U 158 mm (6.3") mounting depth with optional rear cover installed Dual Channel Conductivity/ Resistivity Controller CDCN-91, shown actual size. CDCN-91 Series Specifications General Compatible Sensors: CDCE-90 Series standard conductivity/resistivity sensors Operating Range: Conductivity: 0.055 to 400,000 µS/cm Resistivity: 10 kΩ/cm to 18.26 MΩ/cm (0.055 to 100 µS/cm) TDS: 0.001 to 999999 ppm or ppb (display limit) Temperature: PT1000: -25 to 120°C (-13 to 248°F) Accuracy: Conductivity/Resistivity: ±2% of reading Temperature: ±0.5°C Power Requirements: 100 to 240 Vac: ±10%, 50 to 60 Hz, 20 VA 11 to 24 Vdc: ±10% reg., 0.5A max Display: Alphanumeric 2 x 16 LCD Contrast: User selected, 5 levels Update rate: 1.5 seconds Current Outputs: (3 each) 4 to 20 mA, isolated, fully adjustable and reversible Max Loop Impedance: 150 Ω @ 12V, 450 Ω @ 18V, 750 Ω @ 24V Update Rate: Approx. 100 mS Accuracy: ±0.03 mA @ 25°C, 24 Vdc Open Collector Outputs: (2 each) Isolated, 50 mA sink or source, 30 Vdc max pull-up voltage Operational Settings: Hi, Lo, USP, Pulse, Off Hysteresis: User adjustable Time Delay: 0 to 6400 seconds Maximum Pulse Rate: 400 pulses/minute Alarm Contacts: (up to 4 each) SPDT Relays Maximum Voltage Ratings: 5A @ 30 Vdc or 5A @ 250 Vac Operational Settings: Hi, Lo, USP, Pulse, Off ELECTRONICS The CDCN-91 Series dual channel conductivity/resistivity controller is a two-channel input device equipped with three scalable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with the CDCE-91 Series conductivity sensors listed below, form the perfect measurement and control system for water treatment applications and more. Two versions are available: one accepts AC line-voltage, the other low voltage DC for power. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA 4X (IP65) integrity of the front panel can be extended to the entire enclosure by using the optional rear cover kit.

Over 100,000 Products Available! omega.com ® To download information and to order Conductivity Instrument products online, visit omega.com 102 (4.0) (2.2) 96 (3.8) (3.8) Panel Cutout 92 x 92 ( + 0.8, - 0) 3.6 x 3.6 (+0.031, -0) Optional Rear Cover FP90-4X Panel Model No. Description FP90-4X NEMA 4X (IP65) rear cover kit FPM-5000-LTCK Liquid-tight kit for rear cover CDCN-91-WMB Wall mount bracket FPM-5000-MB Surface mount bracket FP90RC RC filter kit for relays CDCE-90-001 Conductivity cell constant = 0.01 CDCE-90-01 Conductivity cell constant = 0.1 CDCE-90-1 Conductivity cell constant = 1.0 CDCE-90-10 Conductivity cell constant = 10.0 CDCE-90-20 Conductivity cell constant = 20.0 Comes complete with mounting bracket, panel gasket and operator’s manual. Additional cells available. Ordering Example: CDCN-91 conductivity/resistivity controller DC power, with CDCE-90-1 conductivity cell constant. Accessories gasket Rear Cover 4-screws RELAY 1 RELAY 2 RELAY 3 RELAY 4 N/C N/O CO M N /C N/O CO M N/C N/O CO M N/C N/O CO M RELAY 3,4 O PEN CO LL 3,4 - O PEN C O LL 4 O PEN C O LL 4 O PEN C O LL 3 O PEN C O LL 3 LO O P 2 LO O P 2 LO O P 3 LO O P 3 - LO O P 1 LO O P 1 SHLD ISO GND TEM P 1 SGNL 1 SHLD ISO GND TEM P 2 SGNL 2 PO □ ER O UTPUT O PTIO N L N ca□□e Co□□ector □or□ere□ se□arate□□□ 3-8860.540 Dual Channel Conductivity rear terminal pad-printing artwork 4/24/00 REV. E4 SG RELAY 1 RELAY 2 RELAY 3 RELAY 4 N/C N/O COM N/C N/O COM N/C N/O COM N/C N/O COM RELAY 3,4 OPEN COLL 3,4 - OPEN COLL 4 + OPEN COLL 4 - OPEN COLL 3 + OPEN COLL 3 - LOOP 2 + LOOP 2 - LOOP 3 + LOOP 3 - LOOP 1 + LOOP 1 SHLD ISO GND TEMP 1 SGNL 1 SHLD ISO GND TEMP 2 SGNL 2 POWER OUTPUT OPTION Æ REAR OF ENCLOSURE L N 11 - 24□ □□□ A L N + 3-8860.610A 4/00 1□□ - 24□□ Optional heavy-duty wall mount bracket CDCN-91-WMB. Optional surface mounting bracket FPM-5000-MB. quick-clip gasket on front side of panel panel terminals mounting bracket R E L AY 1 R E L A Y 2 R E L AY 3 R E L AY 4 N / C N / O C O M N / C N / O C O M N / C N / O C O M N / C N / O C O M RELAY 3,4 O PEN CO LL 3,4 - O PEN C O LL O PEN C O LL O PEN C O LL O PEN C O LL LO O P 2 LO O P 2 LO O P 3 LO O P 3 LO O P 1 LO O P 1 SHLD ISO GND TEM P 1 SGNL 1 SHLD ISO GND TEM P 2 SGNL 2 P O □ E R O UTPUT O PTIO N L N Panel mounting bracket and panel gasket are included. Liquid tight connector kit 3 sets per kit, FPM-5000-LTCK Use with optional NEMA 4X (IP65) rear cover kit, FP90-4X. Note: This label appears on the side of the instrument case Dimensions: mm (inch) To Order Model No. Description CDCN-91 Conductivity/resistivity controller DC power CDCN-91AC Conductivity/resistivity controller AC/DC power Hysteresis: User adjustable Time Delay: 0 to 6400 seconds Maximum Pulse Rate: 400 pulses/minute Enclosure Rating: NEMA 4X (IP65) front and back with optional NEMA 4X (IP65) rear cover kit Materials: Case: PBT Window: Polyurethane-coated polycarbonate Keypad: Sealed 4-key silicone rubber Weight: CDCN-91AC: Approx. 581 g (20.5 oz) CDCN-91: Approx. 544 g (19.2 oz)