FP30-1600 TRIAD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

PC Mount: Flat Pack ™ Web: www.TriadMagnetics.com Phone 951-277-0757 Fax 951-277-2757 460 Harley Knox Blvd. Perris, California 92571 Publish Date: December 4, 2013 3 7 5687 3 4 2 1 .060 D IA H OLES B EFE G A C D FP30-1600 Electrical Specifications (@25C) 1. Maximum Power: 48 VA 2. Primary Voltage: Series: 230V@ 50/60 Hz Parallel: 115V@50/60Hz 3. Secondary: Series: 30.0VCT @ 1.6Amps Parallel: 15.0V @ 3.2Amps Description: The FP30-1600 is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on two dual channel nylon bobbin. Materials are UL recognized, Class B (130º C) rated. Safety: These products are 100% hipot tested with an insulation of 2000V between primary and secondary windings and 1500V between the primary / secondary windings and the core. Agency File: UL: File E53148, UL 506, Class B General Purpose Transformer, cUL: File E53148, UL 506, Class B General Purpose Transformer, Canadian Use Dimensions: A B C D E F G Units: In inches Weight: 21 .0 oz Pin Dimension: .020 x .041 in Schematic: RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements of 2011/65/EU, known as the RoHS initiative. * Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the most current version.