SURFACE MOUNT GLASS PASSIVATED FAST RECOVERY SILICON RECTIFIER VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. FM4937L THRU FM4933L SMAL MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) Dimensions in inches and (millimeters) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at TA = 55OC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Junction Capacitance (Note 2) SYMBOL VRRM VDC IFSM CJ TSTG VRMS UNITS Volts Volts Volts Amps1.0 Amps 0C/W 0C/W 0 C Storage Temperature Range R q J L Typical Thermal Resistance (Note 1) R q J A IO pF Operating Temperature Range TJ FM4933L -55 to + 150 150 0 C FM4934L FM4935L FM4936L FM4937L FM4933L FM4934L FM4935L FM4936L FM4937L 100 200 400 35 70 140 280 50 100 200 400 600 600 420 2006-12 CHARACTERISTICS Maximum Average Reverse Current Maximum Full Load Reverse Current, Full cycle Average TA =55OC Maximum Reverse Recovery Time (Note 4) at Rated DC Blocking Voltage VF SYMBOL I trr R mA mA mA Maximum Instantaneous Forward Voltage at 1.0A DC Volts 100 200 nSec @TA = 25 o C @TA = 100 o C UNITS 1.2 NOTES : 1. Thermal Resistance : Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
FEATURES
- Ideal for surface mounted applications * Glass passivated device * Low leakage current * Metallurgically bonded construction * Mounting position: Any * Weight: 0.057 gram * Epoxy: Device has UL flammability classification 94V-O MECHANICAL DATA 0.067 ( 1.70 ) 0.063 ( 1.60 ) 0.012 ( 0.305 ) 0.006 ( 0.152 ) 0.008 ( 0.203 ) 0.004 ( 0.102 ) 0.059 ( 1.50 ) 0.035 ( 0.89 ) 0.209 ( 5.31 ) 0.185 ( 4.70 ) 0.180 ( 4.57 ) 0.160 ( 4.06 ) 0.110 ( 2.79 ) 0.086 ( 2.18 ) 0.067 (1.70 ) 0.051 (1.29 )
AMBIENT TEMPERATURE, ( O INSTANTANEOUS REVERSE CURRENT, (mA) 0.8 1.0 0.6 0.4 0.2 7550 175100 125 150 RATING AND CHARACTERISTICS CURVES ( FM4933L THRU FM4937L ) FIG.2 TYPICAL FORWARD CURRENT DERATING CURVE FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) AVERAGE FORWARD CURRENT, (A) 0.1 1.0 1000 100 6020 40 80 100 120 140 FIG.3 TYPICAL REVERSE CHARACTERISTICS trr IFM 1.0 i(t) IRM (REC) 1cm SET TIME BASE FOR 50/100 ns/cm Single Phase Half Wave 60Hz Resistive or Inductive Load TA = 25 O C TA = 75 O C TA = 100 O C 5 4 115Va 10K 60Hz 2W C.P.CLARE HPG 1002
30 Vdc
3.8uH /1.4
1 AMP
1.0uF 300V 50W NON-INDUCTIVE UNIT UNDER TEST 10W NON- INDUCTIVE 1.0uF 300V
1.0 Adc FROM
RIPPLE = 3mVrms MAX MINIMIZE ALL LEAD LENGTHS A-TEKTRONIX 545A. K PLUG IN PRE AMP P6000 PROBE OR EQUIVALENT R1-ADJUSTED FOR 1.4£[ BETWEEN POINT 2 OF RELAY AND RECTIFIER INDUCTIVE = 3.8uH Zout 11/2 MAX DC to 2kHz R2-TEN-1W 10 % CARBON CORE IN PARALLEL TA = 25 FOR RECTIFIER 10 di/dt = 50A/mS
PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS FORWARD VOLTAGE, (V) 110 100 125 150 200 INSTANTANEOUS FORWARD CURRENT, (A) 1.0 0.3 0.1 0.03 0.01 3.0 RATING AND CHARACTERISTICS CURVES ( FM4933L THRU FM4937L ) FIG.4 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT REVERSE VOLTAGE, (V) JUNCTION CAPACITANCE, (pF) 200 100 0.20.1 1 0.4 21.0 4 10 20 40 100 FIG.6 TYPICAL JUNCTION CAPACITANCE 8.3ms Single Half Sine-Wave (JEDED Method) Pulse Width=300uS 1% Duty Cycle TJ = 25 O C TJ = 25 O C
Dimensions in inches and (millimeters) 0.060MIN. ( 1.52 MIN.) 0.220 0.094 MAX. (2.38 MAX.) 0.052 MAX. (1.32 MAX.) (5.58) REF
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi- lity for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" paramet- ers which may be included on RECTRON data sheets and/ or specifications ca- n and do vary in different applications and actual performance may vary over ti- me. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other rela- ted applications where a failure or malfunction of component or circuitry may di- rectly or indirectly cause injury or threaten a life without expressed written appr- oval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rect- ron Inc and its subsidiaries harmless against all claims, damages and expendit- ures. DISCLAIMER NOTICE