VOLTAGE 1200 Volts CURRENT 3.0 Amperes MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. FM3012 -W-A01 SMC MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) Dimensions in inches and (millimeters) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at Ambient Temperature Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Current Squared Time Typical Junction Capacitance (Note 2) SYMBOL VRRM VDC I I2T FSM CJ T STG VRMS UNITS Volts Volts Volts Amps3.0 100 41.5 Amps A2S 0C/W 0C/W 0 C Storage T emperature Ra nge R θJA Typical Thermal Resistance (Note 1) 13R θJL IO pF Operating T emperature Ra nge TJ 150 -55 to + 150 0 C FM3012-W-A01 FM3012-W-A01 1200 1200 840 2012-09 REV: O CHARACTERISTICS Maximum Average Reverse Current at Rated DC Blocking Voltage VF SYMBOL IR µA Maximum Instantaneous Forward Voltage at 3.0A DC Volts 2.0 125 @TA = 25 o C @TA = 100 o C µA UNITS 1.1 NOTES : 1. Thermal Resistance :Mounted on PCB. 2. Measured at 1 MHz and applied reverse voltage of 4.0 volts. 3. "Fully ROHS compliant","100% Sn plating (Pb-free)".

FEATURES

  • Glass passivated device * Ideal for surface mounted applications * Low leakage current * Metallurgically bonded construction * Mounting position: Any * Weight: 0.24 gram * Epoxy : Device has UL flammability classification 94V-0 * MSL: 1 Level MECHANICAL DATA 0.103 ( 2.62 ) 0.079 ( 2.06 ) 0.012 ( 0.305 ) 0.006 ( 0.152 ) 0.008 ( 0.203 ) 0.004 ( 0.102 ) 0.060 ( 1.52 ) 0.030 ( 0.76 ) 0.320 ( 8.13 ) 0.305 ( 7.75 ) 0.280 ( 7.11 ) 0.260 ( 6.60 ) 0.245 ( 6.22 ) 0.220 ( 5.59 ) 0.125 (3.17 ) 0.115 (2.92 ) SURFACE MOUNT GLASS PASSIVATED SILICON RECTIFIER 4. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.

PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) INSTANTANEOUS FORWARD VOLTAGE, (V) INSTANTANEOUS FORWARD CURRENT, (µA) AMBIENT TEMPERATURE, ( O 00.01 1.0 0.1 100 1000 AVERAGE FORWARD CURRENT, (A) CJ, JUNCTION CAPACITANCE, (pF) 1.0 2.0 3.0 4.0 20 40 60 80 100 120 140175125 1505025 75 1000 1.0 1.5 3.0 5.0 RATING AND CHARACTERISTICS CURVES ( FM3012-W-A01 ) FIG.3 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS FIG.1 TYPICAL FORWARD CURRENT DERATING CURVE FIG.2 TYPICAL REVERSE CHARACTERISTICS REVERSE VOLTAGE, (V) INSTANTANEOUS REVERSE CURRENT, (A) 0.1 100 200 400 400.4 1.0 4 10 80 FIG.4 TYPICAL JUNCTION CAPACITANCE NUMBER OF CYCLES AT 60Hz PEAK FORWARD SURGE CURRENT, (A) 100 2 4 6 8 10 20 40 80 100 FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375" (9.5mm) Lead Length TJ = 25 O C Pulse width=300µ S 1% Duty Cycle TJ = 25 O C 8.3mS Single Half Sine-Wave JEDEC Method TA = 25 O C TA = 75 O C TA = 100 O C

Dimensions in inches and (millimeters) 0.121MIN. (3.07 MIN.) 0.320 0.185 MAX. (4.69 MAX.) 0.060 MIN. (1.52 MIN.) (8.127) REF

3 C X

Part No. Year – code: (Y:Last digit of year V oltage-code Rectron Logo Week – code: (WW:01~52)

PACKAGING OF DIODE AND BRIDGE RECTIFIERS REEL PACK PACKAGE GROSS WEIGHT(Kg) EA PER REEL COMPONENT SPACE(mm) TAPE SPACE (mm) CARTON SIZE (mm) (mm) EA PER CARTON REEL DIA --- --- --- --- 330 176 355*360*350 390*205*310 11.50 12,000 24,000 500 3,000 SMC SMC 6.65-T PACKING CODE

Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi- lity for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" paramet- ers which may be included on RECTRON data sheets and/ or specifications ca- n and do vary in different applications and actual performance may vary over ti- me. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other rela- ted applications where a failure or malfunction of component or circuitry may di- rectly or indirectly cause injury or threaten a life without expressed written appr- oval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rect- ron Inc and its subsidiaries harmless against all claims, damages and expendit- ures. DISCLAIMER NOTICE