FLUX-50 SLPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
VAC single phase or 100-370 VDC. fuse on-board. (See Note 1.) the conducted EMI requirements of EN55022/FCC Class B by 10 dB, typical. FLU1-60 series, 60W, max. Auxiliary outputs fixed. nominal load conditions). VAC input), minimum, at full load. output, typical). control. FLU1-60 and FLU3-50 series, 33 kHz, fixed. minute. (See Note 2.) Notes 3, 4.) early 2%/°C from +50°C to +70°C. temperature range. Moving air is recommended for oper- ation in a confined area. 50-60W ✔ Single and Triple Output Models ✔ Universal AC Input ✔ CE Mark: UL/CSA/EN60950 Approvals ✔ EN55022/FCC Class B Input Line Filters ✔ 0% Minimum Load Requirement ✔ Over-Current/Short-Circuit Protection ✔ 2-Year Warranty ✔ Minimum 200,000-Hour MTBF Output Current Output Output Voltage Min. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. AC-DC 50W Singles 85-265 VAC Input AC-DC 50W Triples 85-265 VAC Input AC-DC 60W Singles 85-265 VAC Input * Peak output current rating = 5.0A (<60 seconds, duty cycle <10%). CHARACTERISTICS OPEN-FRAME SWITCHING POWER SUPPLIES 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com POWER GENERAL Rev. PG/ABBB
- Replace the input line fuse with the same type and rating. Recommended: 2A/250V slow-blow fuse. 2. Electrical strength/isolation is 2200 VDC from the input of the supply to ground for 60 seconds. 3. All measurements are made directly at the terminals of the power suppl y. 4. Peak-to-peak and RMS metering equipment must have a 20 MHz fre- quency response with probes and cables that maintain a frequency response of 20 Hz to 20 MHz. Output ripple and spikes are measured directly at the output terminals of the power supply with a 0.1 µF ceramic capacitor. The instruments’ probe ground band must make direct contact with the output return or common terminal of the supply to prevent erro- neous noise measurements. 5. MTBF is calculated using the parts stress method in MIL-HDBK 217F (ground benign, T A = +25°C). 6. Output voltage tolerance is measured under nominal load conditions. 7. Line regulation is measured under nominal load conditions as the input voltage is varied from 85 to 265 VAC. 9. Load regulation is measured at 115 VAC or 230 VAC. For single output models, load regulation is measured while output current is varied from 0% to 100% of full load. With multiple output models, the output under test is brought to 60% of nominal load; load current is then varied +40%/- 30% of nominal while other outputs are held at nominal load conditions. 10. Cross-regulation is tested by changing the load on the primary output from 50% to 100% of nominal load while measuring the voltage change on the auxiliary output under test. 11. The FLU1-50, FLU3-50 and FLU1-60 series are approved to UL1950 (File E140439), CSA22.2 No.234 (File LR52335) and EN60950/IEC950/DIN VDE 0805 (TÜV Licenses R9271543, R9171470, and R9271468). OPEN-FRAME SWITCHING POWER SUPPLIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4030. The mating connector combines Molex housing 43061- 0003 and crimp terminal 08-70-1030. D. P2 output connectors are Molex 26-60-4060. The mating connector combines Molex housing 43061- 0006 and crimp terminal 08-70-1030. 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com POWER GENERAL Pin-Out Pin FLU1-50 1V 1 2V 1 3V 1
4 Return
5 Return
6 Return
Rev. PG/ABBB
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidec.com · http://www.nidec.com POWER GENERAL A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4030. The mating connector combines Molex housing 43061- 0003 and crimp terminal 08-70-1030. D. P2 output connectors: FLU1-60 series—Molex 26- 60-4080, FLU3-50 series—Molex 26-60-4060. Mating connector housings: FLU1-60 series—Molex 43061-0008, FLU3-50 series—Molex 43061-0006. Crimp terminals: Molex 08-70-1030. 50-60W OPEN-FRAME SWITCHING POWER SUPPLIES Model Selection Guide FLU 150 1A D Series Number of Outputs Output Power (W) Output Voltage (Model) Input Voltage D=85-265 VAC Construction A=Open PCB Pin-Out Pin FLU3-50 FLU1-60
1 V2 +Sense §
4 Common V1
5 Common Return
6 V3 Return
7 N/A Return
8 N/A -Sense §
§ If sense terminals are not used, tie together Pins 1 and 2 and tie together Pins 7 and 8. FLU3-50/FLU1-60 SERIES Rev. PG/ABBB