FLUKE-377-E FLUKE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex Voltage and current measurements with FieldSense™ technology The Fluke 377 FC and 378 FC true-rms clamp meters use Field - Sense™ technology to make testing faster and safer, all without touching a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the con - ductor and see reliable, accurate voltage and current values on the display. Power quality indicator shows whether a problem is in the equipment or the power line (378 FC only) The 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem. MEASURE VOLTAGE AND CURRENT With your clamp jaw FASTER, SAFER TESTING All without touching a live wire - using FieldSense™ technology POWER QUALITY INDICATOR Shows whether equipment or power line is faulty COMPLETE 3-PHASE VOLTAGE AND CURRENT TESTS in 3 quick steps The 378 FC includes a power quality test that provides quick indication of whether an incoming power problem or an equipment problem exists.

2 Fluke Corporation Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex

Voltage and current measurements with FieldSense™ technology No more hand-written notes or complicated math.

  • Complete 3-phase voltage and current tests in 3 easy steps
  • Full set of phase-to-ground and phase-to- phase values calculated
  • Displayed on your smart phone and saved to the cloud via Fluke Connect software
  • Phase rotation calculated and shown on the Fluke Connect software Measure extremely high current with iFlex™ probe Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces. Easy to see, easy to use with included tools Your job will get easier when you use the 377FC and 378 FC clamp meter:
  • The display turns green when a stable Field - Sense measurement is detected.
  • Visual Continuity provides a bright green screen for easy detection of continuity in noisy work areas.
  • The TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head.
  • The included carrying case holds the clamp, iFlex probe, test leads and the included black grounding clip. Record, analyze, share results with Fluke Connect™ software With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program. Fluke Connect allows measurements to be sent to a smartphone for logging, collaboration and analysis. Fluke Connect pulls all data related to three-phase measurements including phase rotation and presents the full set of data for analysis at a glance. Data gathered by Fluke Connect can pinpoint elusive intermittent faults. Data collected over regular intervals can be used to spot small changes before they grow into major problems.

3 Fluke Corporation Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex

(between any terminal and earth ground) 1000 V Battery Type 2 AA IEC LR6 alkaline Life 200 hours Display Dual readout Automatic Power Off 20 minutes AC Current: Jaw Range 999.9 A Resolution 0.1 A Accuracy 2 % ± 5 digits (10 Hz to 100 Hz) 2.5 % ± 5 digits (100 Hz to 500 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 AC Current: Flexible Current Probe Range 2500 A Resolution 1 A (≤ 2500 A) 0.1 A (≤ 999.9 A) Accuracy 3 % ±5 digits (5 Hz to 500 Hz) Distance from Optimum i2500-10 Flex i2500-18 Flex Error Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating tempera - ture range. DC Current Range 999.9 A Resolution 0.1 A Accuracy 2 % ±5 digits AC Voltage: FieldSense Range 1000 V Resolution 1 V (≤ 1000 V) Accuracy ≤ 4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz) ≥ 4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz) Position wire as close as possible to jaw opening (see illustration).

4 Fluke Corporation Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex

AC Voltage: Test Leads Range 600.0 V 1000 V Resolution 0.1 V (≤ 600.0 V)

1 V (≤ 1000 V)

Accuracy 1 % ±5 digits (20 Hz to 500 Hz) DC Voltage Range 600.0 V 1000 V Resolution 0.1 V ≤ 600.0 V) Accuracy 1 % ± 5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1 % ± 5 digits Amps Frequency: Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ± 5 digits Trigger Level 5 Hz to 10 Hz, ≥ 10 A

10 Hz to 100 Hz, ≥ 5 A

100 Hz to 500 Hz, ≥ 10 A

Amps Frequency: Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥ 25 A

20 Hz to 100 Hz, ≥ 20 A

100 Hz to 500 Hz, ≥ 25 A

Range 60.00 kΩ 6000 Ω 600.0 Ω Resolution 0.1 Ω (≤ 600.0 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60.00 kΩ) Accuracy 1 % ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100.0 μF)

1 F (≤ 1000 μF)

Accuracy 1 % ±4 digits Mechanical Size (L x W x H) 274 mm x 86 mm x 47 mm Weight (with Batteries) 463 g Jaw Opening 34 mm Flexible Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector) 1.8 m Rogowski Coil Length 450 mm Specifications (continued)

5 Fluke Corporation Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex

Operating Temperature -10 °C to 50 °C Storage Temperature -40 °C to 60 °C Operating Humidity (without condensation) Non condensing (<10 °C) ≤ 90 % RH (10 °C to 30 °C) ≤ 75 % RH (30 °C to 40 °C) ≤ 45 % RH (40 °C to 50 °C) Temperature Coefficients Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C Ingress Protection IEC 60529: IP30 (jaw closed) Operating Altitude 2000 m Storage Altitude 12 000 m Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Safety General IEC 61010-1: Pollution degree 2 Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤ 30 A/m Wireless Radio Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE Frequency Range 2405 MHz to 2480 MHz Output Power <100 mW Radio Frequency Data Go to www.fluke.com and search for “Radio Frequency Data for Class A” (PN 4333628) SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: www.fluke.com/declaration-of-conformity

6 Fluke Corporation Fluke 377 FC, 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meters with iFlex

Ordering information

Fluke 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meter TL224 Test Leads TP175 TwistGuard™ Test Probes AC285 black grounding clip (1 only) i2500-18 iFlex® Flexible Current Probe 18 inch (48 cm) TPAK ToolPak™ Magnetic Meter Hanger Premium carrying case Quick reference guide FLUKE-377 FC Included Fluke 377 FC Non-Contact Voltage True-rms Wireless AC/DC Clamp Meter TL224 Test Leads TP175 TwistGuard™ Test Probes AC285 black grounding clip (1 only) i2500-18 iFlex® Flexible Current Probe 18 inch (48 cm) TPAK ToolPak™ Magnetic Meter Hanger Premium carrying case Quick reference guide Visit www.fluke.com to get complete details on these products or ask your local Fluke sales representative. Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands Fluke. Keeping your world up and running.® For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0)40 267 5100 or Fax +31 (0)40 267 5222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2020 Fluke Corporation. Specifications subject to change without notice. 3/2020 6013559a-en Modification of this document is not permitted without written permission from Fluke Corporation. All trademarks are the property of their respective owners. WiFi or cellular service required to share data. Smartphone, wireless service and data plan not included with purchase. First 5GB of storage is free. Smartphone wireless service and data plan not included with purchase. Fluke Connect is not available in all countries. Preventive maintenance simplified. Rework eliminated. Save time and improve the reliability of your maintenance data by wirelessly syncing measurements using the Fluke Connect system.

  • Eliminate data-entry errors by saving measurements directly from the tool and associating them with the work order, report or asset record.
  • Maximize uptime and make confident maintenance decisions with data you can trust and trace.
  • Move away from clipboards, notebooks and multiple spreadsheets with a wireless one-step measurement transfer.
  • Access baseline, historical and current measurements by asset.
  • Share your measurement data using ShareLive™ video calls and emails.
  • The Fluke 377 FC and Fluke 378 FC clamp meters are part of a growing system of connected test tools and equipment maintenance software. Visit the Fluke website to learn more about the Fluke Connect system. Find out more at fluke.com