116 FLUKE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

with Temperature and Microamps Features include:

  • Built in thermometer for HVAC applications
  • Microamps to test flame sensors
  • LoZ: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for the HVAC professional. It has every - thing needed in an HVAC meter including temperature and microamp measure- ments to quickly troubleshoot problems with HVAC equipment and flame sensors. General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Operating temperature -10 °C to + 50 °C Storage temperature -40 °C to + 60 °C Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight N10140 R Actual size

2 Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps

PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 8/2006 2634037 D-EN-N Rev B Fluke. Keeping your world up and running.™ Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 DC volts 6.000 V 0.001 V 0.5 % + 260.00 V 0.01 V 600.0 V 0.1 V Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms 6.000 V 0.001 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)60.00 V 0.01 V 600.0 V 0.1 V Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer. Ohms 600.0 Ω 0.1Ω 0.9 % + 2 6.000 kΩ 0.001 kΩ 0.9 % + 1 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 1.5 % + 2 Diode test 2.000 V 0.001 V 0.9 % + 2 Capacitance 1000 nF 1 nF 1.9 % + 210.00 µF 0.01 µF 100.0 µF 0.1 µF 9999 µF 1 µF 100 µF to 1000 µF 1.9 % + 2 > 1000 µF 5 % + 20 Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical Temperature2 (Type-K thermocouple) -40 °C to 400 °C 0.1 °C 1 % + 102 -40 °F to 752 °F 0.2 °F 1 % + 182 AC µamps true-rms (45 Hz to 500 Hz) 600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz) DC µamps 600.0 µA 0.1 µA 1.0 % + 2 Hz (V or A input)3 99.99 Hz 0.01 Hz 0.1 % + 2 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 50.00 kHz 0.01 kHz Notes: 1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non- zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 2 Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User’s manual and 9 V battery (installed).