- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
input range 85-265 VAC single phase or 100-370 VDC. DC-input models, 36-75 VDC (48V, nominal). MDU series). Input line fuse provid- ed on-board. (See Note 1.) conducted EMI requirements of EN55022/FCC Class B by 10 dB, typ. ing: 500 µA, maximum. Auxiliary outputs fixed. voltage, nominal load conditions). VAC input), 32 ms (230 VAC input), minimum, at full load control. put for one minute. (Note 3.) MDU Series: 5700 VDC, input-to-out- put for one minute. (Note 3.) Note 5.) linearly 2%/°C from +50°C to +70°C. temperature range. Moving air is recommended for oper- ation in a confined area. CHARACTERISTICS 40W O PEN -FRAME SWITCHING POWER SUPPLIES
- Single, Dual and Triple Output Models
- Universal AC-Input and DC-Input Models
- CE Mark: UL/CSA/EN60950 Approvals
- BABT Approvals
- Austel CCL Certification
- Models with UL544/CSA C22.2-601/EN60-601 Medical Safety Approvals
- EN55022/FCC Class B Input Line Filter
- 0% Minimum Load Requirement
- Over-Current/Short-Circuit Protection
- 2-Year Warranty
- Minimum 200,000-Hour MTBF Output CurrentOutput Output VoltageMin. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. AC-DC Singles 85-265 VAC Input AC-DC Singles To UL544/EN60-601/CSA 22.2-601.1 AC-DC Duals 85-265 VAC Input AC-DC Duals To UL544/EN60-601/CSA 22.2-601.1 POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
Output VoltageMin. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. DC-DC Duals 36-75 VDC Input AC-DC Triples 85-265 VAC Input Output CurrentOutput Output VoltageMin. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. AC-DC Triples To UL544/EN60-601/CSA 22.2-601.1 DC-DC Triples 36-75 VDC Input * Peak output current rating = 5.0A (<60 seconds, duty cycle <10%). † Peak output current rating = 3.0A (<60 seconds, duty cycle <10%). § Peak output current rating = 2.0A (<60 seconds, duty cycle <10%). Notes 1. Replace the input line fuse with the same type and rating. Recommended: 2A/250V slow-blow fuse. 2. The sum of primary and auxiliary output currents from triple output models -1AD through -4AD must not exceed 5.0A. 3. Hi-pot isolation is 2200 VDC from the input of the supply to ground for 60 seconds. 4. All measurements are made directly at the terminals of the power supply. 5. Peak-to-peak and RMS metering equipment must have a 20 MHz frequency response with probes and cables that main- tain a frequency response of 20 Hz to 20 MHz. Output rip- ple and spikes are measured directly at the output terminals of the power supply with a 0.1 µF ceramic capacitor. The probe ground band must make direct contact with the output return or common terminal to prevent erroneous noise mea- surements. 6. MTBF is calculated using the parts stress method in MIL- HDBK 217F (ground benign, T A = +25°C). 7. Output voltage tolerance is measured under nominal load current conditions. 8. Line regulation is measured under nominal load conditions as the input voltage is varied from 85 to 265 VAC (ac-input models) or from 36 to 75 VDC (dc-input models). 9. Load regulation is measured at 115 VAC or 230 VAC. For single output models, load regulation is measured while out- put current is varied from 0% to 100% of full load. With mul- tiple output models, the output under test is brought to 60% of nominal load; load current is then varied +40%/-30% of nominal while other outputs are held at nominal load conditions. 10. Cross-regulation is tested by changing the load on the primary output from 50% to 100% of nominal load while measuring the voltage change on the auxiliary output under test. 11. The FLU1-40, FLU2-40 and FLU3-40 series are approved to UL1950 (File E140439), CSA22.2 No. 234 (File LR52335), EN60950/IEC950/DIN VDE 0805 (TÜV Licenses R679206, R0097621, R9071501), and Austel CCL (Certificate A92/PS/004). 12. The FLU3-40 series has BABT/EN41003 approval ((NS/4199/123/R/604674). 13. The MDU1-40, MDU2-40 and MDU3-40 series are approved to UL544 (File E151357), CSA 22.2 No. 601.1 (File LR52335) and EN60-601/IEC601-1/DIN VDE 0750 (TÜV Licenses R9271474, R9271475, R9271476). 14. The DC2-40 and DC3-40 series are approved to UL1950 (File E140439), CSA22.2 No. 234 (File LR52335), and EN60950/IEC950/DIN VDE 0805 (TÜV License R9071501). O PEN -FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com Model Selection Guide FLU 2 40 1 A D Series FLU=AC Input MDU=AC Input (UL544/IEC601 Safety) DC=DC Input Number of Outputs Output Power (W) Output Voltage (Model) Input Voltage D=85-265 VAC C=36 to 75 VDC Construction A=Open PCB B=L-Bracket C=Full Enclosure
FLU2-40 FLU2-40 FLU3-40 FLU3-40 Pin FLU1-40 MDU1-40 Models 1-4 Models 5-7 MDU2-40 DC2-40 Models 1-4 Models 5-6 MDU3-40 DC3-40
1 V1 V1 V2 +V1 (ISO) V2 V2 V2 +V2 (ISO) V2 V2
2 V1 V1 V1 +V1 (ISO) V1 V1 V1 - V2 (ISO) V1 V1
3V 1 V 1 V 1 - V 1 (ISO) V1 V1 V1 +V1 (ISO) V1 V1
4 Return Return Common - V1 (ISO) Common Common Common +V1 (ISO) Common Common
5 Return Return Common - V2 (ISO) Common Common Common - V1 (ISO) Common Common
6 Return Return N/C +V2 (ISO) N/C N/C V3 - V1 (ISO) V3 V3
7 N/A N/A N/A N/A N/A N/A N/A +V3 (ISO) N/A N/A
8 N/A N/A N/A N/A N/A N/A N/A - V3 (ISO) N/A N/A
A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-62-4030. The mating con- nector combines Molex housing 43061-0003 and crimp ter- minal 08-70-1030. D. P2 output connectors for the 40W series, except for models 5 and 6 of the FLU3-40 series, are Molex 26-60-4060. The mating connector combines Molex housing 43061-0006 and crimp terminal 08-70-1030. Models 5 and 6 of the FLU3-40 series use Molex 26-60-4080 for the P2 connector. The mat- ing connector uses Molex housing 43061-0008 and crimp terminals 08-70-1030. O PEN -FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
To order, change the part number suffix from AD to BD or from AC to BC . 1. Material is 0.036-inch cold-rolled steel (20 AWG). 2. Finish is zinc and clear chromate plating. 3. Dimensions are in inches. 4. Tolerances = 0.00 ±0.01 0.000 ±0.005 L-Bracket and Cover To order full enclosure, change the part number suffix from AD toCD or fromAC to CC . 1. Material is 0.036-inch cold-rolled steel (20 AWG). 2. Finish is zinc and clear chromate plating. 3. Dimensions are in inches. 4. Tolerances = 0.00 ±0.01 0.000 ±0.005 POWER SUPPLY ENCLOSURES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com