FLU50-60 SLPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

voltage range 85-265 VAC single phase or 100-370 VDC. DC-input mod- els, see ratings table. protected, input line fuse on-board. (See Note 1.) Performance surpasses conducted EMI requirements of EN55022/FCC Class B by 10 dB, typical. 50, and DC50 series, 50W, max. FLU1-60 and DC60 series, 60W, max. 300 µA, maximum. Auxiliary outputs fixed. nominal load conditions). VAC input), minimum, at full load. only (120% of rated output, typical). control. fixed. DC50 and DC60 series, 100 kHz, fixed. FLU1-60, FLU2-50, FLU3- 50 series, 33 kHz, fixed. for one minute. MDU Series: 5700 VDC, input-to-output for one minute. DC50 and DC60 Series, 2500 VDC input-to-output for one minute. (See Note 2.) peak, maximum. (See Notes 4, 5.) early 2%/°C from +50°C to +70°C. temperature range. Moving air is recommended for opera- tion in a confined area. 50-60W

  • Single, Dual and Triple Output Models
  • Models with Universal AC Input or DC Input
  • CE Mark: UL/CSA/EN60950 Approvals
  • Models to UL544/CSA C22.2-601/EN60-601 Medical Safety Standards
  • EN55022/FCC Class B Input Line Filters
  • 0% Minimum Load Requirement
  • Over-Current/Short-Circuit Protection
  • 2-Year Warranty
  • Minimum 200,000-Hour MTBF Output Current Output Output Voltage Min. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. AC-DC 50W Singles 85-265 VAC Input AC-DC 50W Singles To UL544/EN60-601/CSA 22.2-601.1 AC-DC 60W Singles 85-265 VAC Input AC-DC 50W Duals 85-265 VAC Input * Peak output current rating = 5.0A (<60 seconds, duty cycle <10%). † Peak output current rating = 2.5A (<60 seconds, duty cycle <10%). Optional L-bracket enclosures for the FLU1-50 series are available. For details, see dimension drawings for the Power General 40W series. CHARACTERISTICS OPEN-FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
  1. For FLU and MDU models, replace the input line fuse with the same type and rating. Recommended: 2A/250V slow-blow fuse. For the DC50 series, an external input line fuse is recommended: For 12V input models, use a 10A/125V fuse; for 24V input, use a 5A/125V fuse; for 48V input models, use a 3A/125V fuse. For the DC60 series, an external input line fuse is recommended: For 12V input models, use a 10A/125V fuse; for 24V input, use a 6A/125V fuse; for 48V input models, use a 4A/125V fuse. 2. Hi-pot isolation is 2200 VDC from the input of the supply to ground for 60 seconds. 3. All measurements are made directly at the terminals of the power supply. 4. Peak-to-peak and RMS metering equipment must have a 20 MHz fre- quency response with probes and cables that maintain a frequency response of 20 Hz to 20 MHz. Output ripple and spikes are measured directly at the output terminals of the power supply with a 0.1 µF ceramic capacitor. The instruments’ probe ground band must make direct contact with the output return or common terminal of the supply to prevent erro- neous noise measurements. 5. For DC50-1 and DC50-2 models, 100 kHz noise and ripple at the 5V out- put is 20 mV pp, typical; at auxiliary outputs, it is 5 mV pp, typical. For DC50-3 and DC50-4 models, 100 kHz noise and ripple is 20 mV pp, typi- cal, for all outputs. For DC60 models, 100 kHz noise and ripple is typically 20 mV pp. 6. MTBF is calculated using the parts stress method in MIL-HDBK 217F (ground benign, TA = +25°C). 7. Output voltage tolerance is measured under nominal load conditions. 8. Line regulation is measured under nominal load conditions as the input voltage is varied from 85 to 265 VAC (ac-input models) or from minimum to maximum input voltage (dc input models). 9. Load regulation is measured at 115 VAC or 230 VAC (ac input models) or at nominal input voltage (dc input models) . For single output models, load regulation is measured while output current is varied from 0% to 100% of full load. With ac-input, multiple output models, the output under test is brought to 60% of nominal load; load current is then varied +40%/- 30% of nominal while other outputs are held at nominal load conditions. With dc-input models, load regulation on an output is measured from nominal to maximum and minimum load while other outputs are held at nominal load conditions. 10. Cross-regulation is tested by changing the load on the primary output from 50% to 100% of nominal load while measuring the voltage change on the auxiliary output under test. 11. The FLU1-50, FLU2-50, FLU3-50 and FLU1-60 series are approved to UL1950 (File E140439), CSA22.2 No.234 (File LR52335) and EN60950/IEC950/DIN VDE 0805 (TÜV Licenses R9271543, R9171470, and R9271468). Output Current Output Output Voltage Min. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. AC-DC 50W Triples 85-265 VAC Input * Peak output current rating = 5.0A (<60 seconds, duty cycle <10%). Input Voltage Output Output Current Output Model (V) (V) (V) Output (V) (A) (A) (A) Tol. Reg. Reg. DC-DC 50W Triples DC-DC 50-72W Singles DC60-1A 10 12 18 V1 5 0.0 10 10 5.0% 0.2% 0.2% DC60-1B 18 24 36 V1 5 0.0 12 12 5.0% 0.2% 0.2% DC60-1C 36 48 72 V1 5 0.0 12 12 5.0% 0.2% 0.2% § DC50 and DC60 models include under-voltage shutdown (10% below lo W line, remote shutdown (TTL HIGH disables the unit), and external frequency synchronization (2.8V positive pulse >9.1 µs at the synch pin). OPEN-FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com

FLU1-50 AND MDU1-50 SERIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4030. The mating connector combines Molex housing 43061-0003 and crimp terminal 08-70-1030. D. P2 output connectors are Molex 26-60-4060. The mating connector combines Molex housing 43061-0006 and crimp terminal 08-70-1030. Pin-Out Pin FLU1-50 MDU1-50 1V 1 V 1 2V 1 V 1 3V 1 V 1

4 Return Return

5 Return Return

6 Return Return

A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4080. The mating connector combines Molex housing 09-50-8081 and crimp terminal 03-50-0106. D. P2 output connectors are Molex 26-60-4100. The mat- ing connector combines Molex housing 09-50-8101 and crimp terminal 03-50-0106. E. Under-voltage shutdown on the DC50 series is activated at 10% below low line, typical. Over-voltage shutdown is typically activated at 10% above high line. F. A TTL HIGH signal at the external shutdown pin of the DC50 series disables the unit. G. External frequency synchronization of the DC50 series requires a 2.8V positive pulse (>9.1 µs) at the external synch pin. Pin-Out Pin DC50 1V 3

2 V3 Return

5 V2 Return

6 V2 Return

9 V1 Return

10 V1 Return

OPEN-FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com

Pin FLU2-50 Models 1-3 Models 4-5 FLU1-60

1 V2 V2 +V2 (ISO) +Sense§

2V 1 V 1 - V 2 (ISO) V1

3 V1 V1 +V1 (ISO) V1

4 Common Common +V1 (ISO) V1

5 Common Common +V1 (ISO) Return

6 N/C V3 - V1 (ISO) Return

7 N/A N/A - V1 (ISO) Return

8 N/A N/A - V1 (ISO) -Sense§

9 N/A N/A - V3 (ISO) N/A

10 N/A N/A +V3 (ISO) N/A

§ If sense terminals are not used, tie together Pins 1 and 2 and tie together Pins 7 and 8. A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-60-4030. The mating connector combines Molex housing 43061-0003 and crimp terminal 08-70-1030. D. P2 output connectors: FLU1-60 series—Molex 26-60-4080 FLU2-50 series—Molex 26-60-4060 FLU3-50 series, Models 1, 2, 3—Molex 26-60-4060 FLU3-50 series, Models 4, 5—Molex 26-60-4100 Mating connector housings: FLU1-60 series—Molex 43061-0008. FLU2-50 series—Molex 43061-0006. FLU3-50 series, models 1, 2, 3—Molex 43061-0006. FLU3-50 series, models 4, 5—Molex 43061-0010. Crimp terminals: All models—Molex 08-70-1030. 50-60W A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. Under-voltage shutdown on the DC60 series is activated at 10% below low line, typical. Over-voltage shutdown is typically activated at 10% above high line. D. A TTL HIGH signal at the external shutdown pin of the DC60 series disables the unit. E. External frequency synchronization of the DC60 series requires a 2.8V positive pulse (>9.1 µs) at the external synch pin. Pin-Out Terminal DC60 1 +Sense § 2V 1 3V 1

4 Return

5 Return

6 -Sense § § If Sense terminals are not used, tie together Terminals 1 and 2 and tie together Terminals 5 and 6. DC60 SERIES FLU2-50/FLU3-50/FLU1-60 SERIES OPEN-FRAME SWITCHING POWER SUPPLIES POWER GENERAL152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com