Technical content
Features
- Initiating Device Circuits (IDCs) may be individually configured for: > General Alarm > Waterflow > Supervisory > Alarm Verification Supervisory operation may be Latching or Non-Latching Notification Appliance Circuits (NACs) may be programmed as: > Silenceable > Non-Silenceable > Auto-Silenceable > Coded (March Time, Temporal Code, California Code) 5.0 Amps of total NAC power Common Alarm, Supervisory and Trouble contacts Resettable four-wire smoke detector power @ 100 mA Integral Walk Test operation EIA-485 interface for up to 3 model RA8 Remote Annunciators Polarity Reversal and City Tie connection (optional) Digital Alarm Communicator Transmitter - DACT (optional) Relay-by-zone capability with RY4 (Flex 4) or RY8 (Flex 8) modules CS-2081 Rev. 1201-3 Page 1
DACT Digital Alarm Communicator Transmitter/Dialer Remote Trouble Indicator RA8 Remote Annunciator Configuration and Programming Tool CFG Relay Module RY8
Flex 4 & Flex 8 Fire Alarm Control Panels Primary Input Power: 102—132 VAC, 60 Hz, 4 Amp Secondary Power: Two 12-volt batteries (in series) Battery Charging Capacity: Up to 24 Amp hours max. Initiating Device Circuits: 26 VDC, .003 A standby, 1.5Vp-p ripple, .050 A max. (alarm), power-limited IDC Compatibility Identifier: “GWC01” Total Output Power: 6 Amp maximum NAC Output Ratings: 24 VDC unfiltered, 1.7 Amp max. / circuit (5 Amp max.), power-limited Auxiliary Power Output: 24 VDC unfiltered, .3 A max., power-limited 4-Wire Smoke Power: 28 VDC unfiltered, .100 A max., 1.5Vp-p ripple, resettable, power-limited Current Consumption: .110 A standby, .220A alarm Main Circuit Board Fuse: 10 Amp Auxiliary Relays: Alarm, Trouble, Supervisory: 1 Amp resistive, 28VDC, Form-C EIA-485 Connection: Connects up to 3 RA8 Remote Annunciators Trouble Indication Output: Controls single RTI Remote Trouble Indicator End-of-Line resistor (30177): 3.9 K-Ohm, 1/2 Watt, 5% with spade lugs—UL Listed Flex 4 & Flex 8 Optional Modules RA8—Remote Annunciator, 8-Zone: Current Consumption: .035 A standby, .090 A alarm RTI—Remote Trouble Buzzer: Current Consumption: .035 A standby, .035 A alarm DACT—Digital Alarm Communicator Transmitter: Current Consumption: .045 A standby, .120 A alarm RY4—Relay Module, 4 Form-C: Current Consumption: .005 A standby, .160 A alarm 1 Amp resistive, 28 VDC RY8—Relay Module, 8-Form-C: Current Consumption: .005 A standby, .160 A alarm 1 Amp resistive, 28 VDC PRM—Polarity Reversal / City Tie Module: Current Consumption: .035 A standby, .3 A alarm Supervised City Tie: 24 VDC unfiltered, .210 A max., 14 Ohms trip coil, NOT power-limited Polarity Reversal: 24 VDC open, 12 VDC @ .003 A, .008 A max. (shorted), power-limited CEM—Circuit Expander Module (Flex 4 only): Current Consumption: .045 A standby, .120 A alarm Initiating Device Circuits: 22 VDC, .003 A standby, 1.5Vp-p ripple, .050 A max. (alarm), power- limited IDC Compatibility Identifier: “GWC01” NAC Output Ratings: 24 VDC unfiltered, 1.7 Amp max. / circuit , power-limited Cabinet Dimensions: 14” H x 14” W x 5” D Battery Space: Two 12 AH batteries max. Relative Humidity: 93% non-condensing Temperature Rating: 0°C - 49°C (32°F– 120°F) CS-2081 Rev. 1201-3 The Flex 4 and Flex 8 can meet the following UL installation system designations (with indicated options selected): Local, Auxiliary (using PRM), Remote Station Protected Premises (using DACT or PRM), Central Station Protected Premises (using DACT). Type of Service / Signaling A, M, WF, SS (SS is only Local or with DACT)/Non-coded
Ordering Information
Flex 4 Four-zone, expandable, microprocessor-based Fire Alarm Control Panel with 4 Class B (Style B) or 2 Class A (Style D) Initiating Device Circuits (IDCs), 2 Class A/B (Style Z/Y) Notification Appliance Circuits (NACs) and a 6 Amp power supply. Expandable up to 8 Class B (Style B) IDCs or 4 Class A (Style D) and 4 Class A/ B (Style Z/Y) NACs. Allows for installation of one DACT Digital Alarm Communi- cator Transmitter or one PRM Polarity Reversal / City Tie Module and one RY4 or RY8 Auxiliary Relay Module. Red, surface- or flush-mount enclosure with CAT-60 key locked door. Flex 8 Eight-zone, microprocessor-based Fire Alarm Control Panel with 8 Class B (Style B) or 4 Class A (Style D) Initiating Device Circuits, 4 Class A/B (Style Z/Y) Notification Appliance Circuits and a 6 Amp Power Supply. Allows for Installation of one DACT Digital Alarm Communicator Transmitter or one PRM Polarity Reversal / City Tie Module and one RY4 or RY8 Auxiliary Relay Module. Red, surface- or flush-mount enclosure with CAT-60 key locked door. Accessories CEM Circuit Expander Module to field modify a Flex 4 to a Flex 8 DACT Digital Alarm Communicator Transmitter Module. Transmits in ADEMCO Contact ID and SIA-DCS protocols. CFG configuration and diagnostics tool is required for programming. PRM Polarity Reversal / City Tie Module. (Note: Only one of a DACT or PRM module can be used with the Flex 4 or Flex 8). RY4 Auxiliary Relay Module with 4 configurable, Form-C relays. Relays programmable for: Relay-by-Zone, Common Alarm, Common Supervisory, etc. RY8 Auxiliary Relay Module with 8 configurable, Form-C relays. Relays programmable for: Relay-by-Zone, Common Alarm, Common Supervisory, etc. RTI Remote Trouble Indicator with trouble LED and piezo buzzer. RA8 Remote Annunciator with common control features, indicators and 8 bi-colored LEDs. 30177 UL Listed, End-of-Line Resistor assembly with wire leads and spade lugs. CFG Hand-held Configuration and Diagnostics programming tool for DACT. 71954-M Set of Manuals for the Flex 4 and Flex 8 product line 72052 Flex 4 and Flex 8 Main Board/Display replacement. Batteries B12V4 Battery, 12 VDC, 4 Ampere Hour (2 required per panel). B12V7 Battery, 12 VDC, 7 Ampere Hour (2 required per panel). B12V12 Battery, 12 VDC, 12 Ampere Hour (2 required per panel). The Gamewell Company Voice (508) 231-1400 60 Pleasant St. 888-FIREBOX
- (888) 347-3269 Ashland, MA 01721 FAX (508) 231-0900 www.gamewell.com Gamewell 2001 Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell assumes no responsi- bility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell. CS-2081 Rev. 1201-3 Page 4