FEAFEAFEAFEAFEATURESTURESTURESTURESTURES Can be used to transmit the FCINET RS-485 data between a 7200 fire alarm control panel, and up to fifteen (15) Distributed Intelligent Units (DIU) via Fiber Optic Cable Provides a Fiber Optic connection between the 7100 and 7200 Series fire alarm control panel and multiple annunciators Allows a Fiber Optic cable link between a Personal Computer, Printer or Video Terminal to 7100 and 7200 Series Fire Alarm Control Systems over long distances Tolerates up to 10 dB signal loss between each FLD-1 module Fiber Optic Cable offers High Immunity from Interference, Transients and Volt- age Spikes Automatically adjusts to different RS-232 Baud rates Uses Industry Standard ST Connectors FIBER OPTIC LINE DRIVER MODULE DESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTIONDESCRIPTION The Fiber Optic Line Driver module (FLD-1) provides fiber optic cable communi- cations between system modules that will be free of ground faults, transients, or noise in- terference. This affords greater reliability and is a more robust application for those instal- lations requiring communications running outdoors between structures. It connects to the RS-232 and RS-485 ports of the FCI 7100 and 7200 Series fire alarm control panels. The FLD-1 converts either RS-232 or RS- 485 signals to a powerful optical signal that can tolerate a signal loss of up to 10 dB. It uses half duplex data flow, an asynchronous protocol, and runs at speeds of up to 19.2 KBps for RS-232 and 128 KBps for RS-485 communications. The FLD-1 is equipped with ST connec- tors that will support standard fiber optic cable up to 200 microns (multimode). Opti- mal results can be achieved with 62.5/125 micron cable. The FLD-1 provides two modes of opera- tion, the Network Mode or the Point-to-Point Mode, selectable through DIP Switch settings on board the FLD-1. Network ModeNetwork ModeNetwork ModeNetwork ModeNetwork Mode Using this mode the following configura- tions are possible: FLD-1 Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no re- sponsibility is assumed by Gamewell-FCI for their use. Specifications subject to change without notice. © 2006 All Rights Reserved www.gamewell-fci.com 9020-0517 Rev. D Page 1 of 4 Point-to-Point Mode When configured in the Point-to-Point Mode, a single 7100 or 7200 Series control panel may use its RS-232 port to connect to a single printer, video terminal or per- sonal computer (PC) via a fiber optic link. Each location requires an FLD-1. INSTALLATION The FLD-1 module mounts inside its own steel cabinet, which can be located up to 15 feet (4.6 meters) away, using rigid con- duit. The dimensions of the cabinet are 10 1/4” W x 10” H x 3” D (26.04 x 25.40 x 7.62 cm). Operating power for the FLD-1 is obtained from the 7200 or 7100 panel, and is con- nected to the FLD-1 via terminal block. RS- 485 connections are also made via termi- nal block, and RS-232 connections are made using a standard RJ-11 cable. An ISO 9001 CompanyAn ISO 9001 CompanyAn ISO 9001 CompanyAn ISO 9001 CompanyAn ISO 9001 Company The FCI 7200 RS-485 FCINET® can be exported via Panel Bus Adapter (PBA) or local Keyboard Display Unit (KDU\\L) from the main panel contain- ing the System Control Unit (SCU) to up to fifteen remotely located KDUs, Remote Annunciator Units (RAUs), and sub-panels containing the Distributed Intelligent Unit (DIU). Each location re- quires one FLD-1. The RS-485 communication output of the FCI 7100 can be converted to an optical link and brought to as many as five remotely located LCD-7100 alphanumeric displays or LDM-7100 remote annunciator drivers. Each location requires an FLD-1. A Honeywell Company
www.gamewell-fci.com FIRE CONTROL INSTRUMENTS FLD-1 PCB 1700-0202 MADE IN USA TB1 231 RS-485 J1RXA LED3 RS- RS- LED4 LED1 PNTNET- LED2 RXA ASSEMBLY 1120-0820 321 4 WORK232 485 MODE RXB TXA TXB LED6 LED8 LED5 LED7 TERM SW1 ON 1234 TB2 TXA RXB TXB COM A COM B +24V GND EGND From J4 connector (TXB) of next FLD-1 From J5 connector (RXB) of next FLD-1 To J3connector (RXA) of previous FLD-1 To J2 connector (TXA) of previous FLD-1 To RS-232 RJ-11 jack of 7200 SCU (connector J1) or 7100 BSM (connector J3) To 7100 TB5-1 or
7200 PBA TB1-3,
7200 PBA TB1-4,
7200 SPSU-V TB1-1 or 2
7200 SPSU-V TB1-3 or 4
Module layout showing connection points GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
www.gamewell-fci.com Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no responsibility is assumed by Gamewell-FCI for their use. Specifications subject to change without notice. © 2006 All Rights Reserved 9020-0517 Rev. C / Page 2 of 4
www.gamewell-fci.com FLD-1
7200 Series Control Panel w/SCU
(Main Control Panel)
7200 Series Distributed System w/DIU
(Sub-system) (Sub-system) FCINET RS-485 from KDU/L or PBA (45’ max. in rigid conduit) FLD-1 FLD-1 RS-232 from SCU J1 connector (45’ max. in rigid conduit) FLD-1 (Sub-system) FLD-1 FCINET RS-485 into DIU (45’ max. in rigid conduit) FCINET RS-485 into DIU (45’ max. in rigid conduit) Up to 10 dB Loss Up to 10 dB Loss between each FLD-1 Printer FLD-1s set to Point-to-Point Mode Keyboard Display Unit FCINET RS-485 into DIU (45’ max. in rigid conduit) FLD-1 FLD-1 Up to 10 dB Loss Typical 7200 Distributed System using FLD-1 modules GAMEWELL-FCI www.gamewell-fci.com Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no responsibility is assumed by Gamewell-FCI for their use. Specifications subject to change without notice. © 2006 All Rights Reserved 9020-0517 Rev. D / Page 3 of 4
www.gamewell-fci.com ORDERING INFORMAORDERING INFORMAORDERING INFORMAORDERING INFORMAORDERING INFORMA TIONTIONTIONTIONTION PART NUMBER 1100-0429 OPERATING VOLTAGE 24 VDC (nominal) @ 0.045 amp (all modes) 32° to 120° F (0° to 49° C) 0 to 85% (non-condensing) Asynchronous with half-duplex data flow RS-232 up to 64 KBps RS-485 up to 128 KBps Up to 200 microns (multimode), optimized for 62.5/125 microns 1/4” W x 10” H x 3” D (26.04 x 25.40 x 7.62 cm)
DESCRIPTION
U.L. 864 File S1949 FM Approved CSFM 07300-0694:251 FCC Part 15 MODEL FLD-1 Fiber Optic Line Driver Module with Back Box SPECIFICASPECIFICASPECIFICASPECIFICASPECIFICA TIONSTIONSTIONSTIONSTIONS Point-to-Point Mode RxA RxBTxA TxB Network Mode RxA TxB RxB RxA TxB RxB RxA TxB RxB RxA TxB RxBTxA TxA TxATxA GAMEWELL-FCI www.gamewell-fci.com Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no responsibility is assumed by Gamewell-FCI for their use. Specifications subject to change without notice. © 2006 All Rights Reserved 9020-00517 Rev. D / Page 4 of 4