FL1F IDEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

Versatile FL1F to simplify wiring, adjustments, and settings of systems. Change your complicated system of multiple relays, timers, and counters to a single IDEC SmartRelay. The IDEC SmartRelay replaces many functions of peripheral equipment of the programmable logic controller. Features 10A max. output contacts and up to 192 display characters. 46 different types of function blocks make it possible to perform various control operations easily. Easy relay/ timer control and remote monitoring New functions are applicable only to base module FS05 or later and WindLGC Ver. 8.2 or later. Ver.UP! Remote Monitoring FL1F Access Tool Reduces Development Time

  • Remote monitoring via PCs and smart devices
  • FL1F WEB EDITOR enables easy design of web browser screen High Maintainability
  • Supports micro SD memory card
  • Clock backup for 20 days
  • New auto clock adjust function via NTP
  • Simulation functions and online testing capabilities
  • With 2 new additional function blocks (Float to integer conversion), a total of 46 types are available
  • Supports user-de/f_ined function blocks
  • Microsoft Excel add-in-tool available
  • Ideal for managing periodic performance such as real time status monitoring and daily reports High Expandability
  • Text display
  • 6 types of I/O expansion modules
  • Connects to peripheral equipment using Modbus TCP communication (server/client, 16 connections)
  • Up to 16 connections are enabled with 1:n communication Multiple Variations
  • 100 to 240V AC/DC, 24V DC
  • 24V AC/DC, 12/24V DC
  • Basic model without LCD display available Easy-to-See LED Display
  • Backlight in 3 colors (white, amber, red)
  • Message display Easy Operation
  • Small LCD display and control switches
  • Operating Temperature –25 to +55°C (no freezing) Analogue Timer Relay Counter PLC Relay terminal Sensor Display Motor Solenoid Valve High environmental resistance FL1F

IDEC SmartRelay is More Convenient Than Ever Before NEW NEW NEW Float to integer conversion Integer to /f_loat conversion Errors and alarms can be displayed with a choice of white, amber, and red backlighting, according to the status level. Reports the Status by 3-color Backlight Using a scroll function, a maximum of 192 one-byte characters (6 lines, 16 characters) in the Base Module, and a maximum of 240 one-byte characters (6 lines, 20 characters) in the Text Display, can be displayed. Reports by Messages Using the LCD display and control switches, parameters can be changed and programs can be added on-site. Settings can be Modi/f_ied On-Site Analog values can be presented not only in integers but also /f_loating points. New add-in-tool available for Microsoft Excel. Easy operation control using accustomed Microsoft Excel functionality. Useful for managing technical documents using tables and graphs. New FL1F WEB EDITOR enables easy design of an user-friendly web page. The graphical display achieves intuitive operation and management. Settings of the base module of multiple units can be controlled and updated on a Text Display. Under the administrator mode, user programs can be easily modi/f_ied. Batch Control through the Display Data communication systems between IDEC SmartRelays can be easily established without any communication programs. 1: n communication with a maximum of 16 connections is available. FL1F Communication I/O for a maximum of 60 points, 12 units can be expanded (maximum con/f_igurations are DI24 / DO20 / AI8 / AO8), enabling design changes easy to handle. Equipped with the user-de/f_ined function blocks, set control patterns can be made into blocks for repetitive uses. Reduces Development Time (2) WindLGC, application software for IDEC SmartRelay, is capable of developing 3 programs at the same time. Reduces Development Time (1) Uploading and downloading of programs can be remotely controlled through Ethernet. Reduces Maintenance Time

  • Documents (CAD, Manuals) • Application Example • Sample Programs • FL1F Access Tool • FL1F WEB EDITOR Product details, documents, and sample program available on website. Amber White Red Capable of Handling Various Scenarios Expandability for Easy Design Changes Operation Management Remote Monitoring New functions are applicable only to base module FS05 or later and WindLGC Ver. 8.2 or later. www.idec.com USA IDEC Corporation Tel: +1-408-747-0550 opencontact@idec.com Germany APEM GmbH Tel: +49-40-25 30 54 - 0 service@eu.idec.com Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155 info@sg.idec.com Thailand IDEC Asia (Thailand) Co., Ltd Tel: +66-2-392-9765 sales@th.idec.com Australia IDEC Australia Pty. Ltd. Tel: +61-3-8523-5900 sales@au.idec.com Taiwan IDEC Taiwan Corporation Tel: +886-2-2698-3929 service@tw.idec.com China/Shanghai IDEC (Shanghai) Corporation Tel: +86-21-6135-1515 idec@cn.idec.com China/Shenzhen IDEC (Shenzhen) Corporation Tel: +86-755-8356-2977 idec@cn.idec.com China/Beijing IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com Japan IDEC Corporation Tel: +81-6-6398-2527 marketing@idec.co.jp Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
  • Ethernet is a registered trademark of Xerox Corporation.
  • Microsoft Excel® is a trademark of US based Microsoft Corporation in the United States and other countries.
  • All trademarks and registered trademarks described in this catalog are the property of their respective owners.
  • Speci/f_ications and other descriptions in this brochure are subject to change without notice.
  • Information in this catalog is current as of February, 2019. EF1005-3 2019 IDEC Corporation, All Rights Reserved.
  • Maximum I/O 60 points: (24DI + 20DO + 8AI + 8AO)
  • Maximum programming capacity: 8,500 bytes (400 function blocks)
  • Operating temperature: -20 to +50oC (*1) (*2)
  • For Base Modules with LCD display, not only program editing and monitoring of function blocks, but also addition and deletion of programs can be performed. The user interface enables intuitive operation. Programs can be modified quickly.
  • For Base Modules with LCD display, a backlight display with 3 colors (white, amber, red), which can display 16 characters x 6 lines, is available (2-byte characters also available).
  • Data is stored in a non-volatile memory, which provides no limit in backup time.
  • With a built-in clock function, a maximum of 20-day backup is possible (at ambient temperature of 25°C.) Also, NTP function adjusts the clock automatically when connected to the internet.
  • Equipped with a micro SD memory card slot, program downloading and data logging is possible using a commercially-available memory card.
  • Ethernet communication port (RJ45). No cables required for downloading and uploading user programs. Also, Modbus TCP (server / client / 16 connection) for communicating with peripheral equipment is available. (*1) Base Modules Package Quantity: 1 Rated Power Voltage Input Signal Output Signal Display Clock I/O Points Weight (approx.) Part No. 24V DC DC (*1) I1, I2, I7 and I8 are used for digital/analog inputs Transistor Yes Yes 8/4 points 195g FL1F-H12SCD 12/24V DC Relay Yes Yes 8/4 points 240g FL1F-H12RCE — 200g FL1F-B12RCE 24V AC/DC AC/DC (*1) Relay Yes Yes 8/4 points 240g FL1F-H12RCA — 200g FL1F-B12RCA 100 to 240V AC/DC AC/DC Relay Yes Yes 8/4 points 240g FL1F-H12RCC — 200g FL1F-B12RCC *1) With NPN/PNP sensor input. For details, see “Input Internal Circuits” on page 5. Expansion I/O Modules (*2) (*3) Package Quantity: 1 Type Rated Power Voltage Input Signal Output Signal I/O Points Weight (approx.) Part No. Input/Output 24V DC DC Transistor 4/4 points 95g FL1F-M08B1S2 12/24VDC DC Relay 4/4 points 130g FL1F-M08B2R2 24V AC/DC AC/DC (*4) Relay 4/4 points 130g FL1F-M08D2R2 100 to 240V AC/DC AC/DC Relay 4/4 points 130g FL1F-M08C2R2 Analog Input 12/24V DC Analog — 2/0 points 95g FL1F-J2B2 Analog Output 24V DC — Analog 0/2 points 95g FL1F-K2BM2 *2) I/O points within the range of the maximum expansion I/O points can be used. *3) When using modules of the same power voltage, supply power to the Base Module and Expansion I/O Modules using one power supply. When power is supplied to the modules from different power supplies, the fast transient burst is 1 kV (IEC61000-4-4). *4) With NPN/PNP sensor input. For details, see “Input Internal Circuits” on page 5. Text Display for FL1F Package Quantity: 1 Rated Power Voltage Weight (approx.) Part No. Remarks 24V AC/DC 12V DC 220g FL1F-RD1 Supplied with a mounting clip and gasket Options Name Part No. Ordering No. Package Quantity Remarks Mounting Clip for Base Module (*6) FL1F-PSP1 FL1F-PSP1PN05 5 Supplied with a module Mounting Clip and Waterproof Gasket for Text Display (*7) FL1F-KW1 FL1F-KW1 1 Supplied with Text Display IDEC SmartRelay User’s Manual (English) FL9Y-B1789 FL9Y-B1789 1 Downloadable from: http://www.idec. com/download *5) DVD-ROM (Including online help manual) *6) Supplied with a Base Module and an Expansion I/O Module. *7) Supplied with a Text Display, it includes a gasket, four mounting clips, and a power supply connector.
  • Web server function available. “FL1F WEB EDITOR” function in WindLGC enables easy and expressive design of web pages by drag and drop.
  • With 1:n communication, a system with a maximum of 16 connections can be built.
  • New function block available (float to integer, integer to float conversion function block.) (*1)
  • “FL1F Access Tool” enables easy operation control using accustomed Microsoft Excel functionality. (*1) (*3)
  • The Text Display for FL1F is a backlight LCD display (160 x 96 dots) available in 3 colors (white, amber, and red). Display of up to 20 characters x 6 lines. Scrolling, blinking, and bar graph available.
  • Five new function blocks available (astronomical clock, analog filter, maximum and minimum, average, stop watch). *1) When FS is 05 or later. WindLGC Ver. 8.2 or later is required for FS 05 or later. *2) When FS is 04 or earlier: 0 to +55oC *3) Microsoft Excel Version 2010, 2013 New IDEC SmartRelay FL1F enhances both high performance and easy control. FL1F

Base Module Specifications Base Module Type No. FL1F-H12SCD FL1F-H12RCE FL1F-B12RCE FL1F-H12RCA FL1F-B12RCA FL1F-H12RCC FL1F-B12RCC Power Supply Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC Rated Frequency — — 47 to 63 Hz 47 to 63 Hz Current Draw 25 to 50 mA (24V DC) 1.2A (with max. load on digital output) 50 to 165 mA (12V DC) 25 to 90 mA (24V DC) 60 to 185 mA (12V DC) 25 to 100 mA (24V DC) 23 to 46 mA (100V AC) 15 to 25 mA (240V AC) 12 to 23 mA (100V DC) 5 to 15 mA (240V DC) Allowable Momentary Power Interruption — 2 ms Typ. (12V DC) 5 ms Typ. (24V DC) 5 ms Typ. (24V AC/DC) 10 ms Typ. (100V AC/DC) 20 ms Typ. (240V AC/DC) Power Consumption 1.2 W (24V DC) 2.0 W (12V DC)

2.2 W (24V DC)

4.4 W (24V AC)

3.2 W (24V DC)

4.6 W (100V AC)

6.0 W (240V AC)

2.3 W (100V DC)

3.6 W (240V DC)

Reverse Polarity Protection Yes Yes — — Clock Backup Duration 20 days (+25o C Typ.) 20 days (+25o C Typ.) 20 days (+25o C Typ.) 20 days (+25o C Typ.) Clock Accuracy ±2 sec/day (Typ.) ±2 sec/day (Typ.) ±2 sec/day (Typ.) ±2 sec/day (Typ.) Input Input Signal DC DC AC/DC AC/DC Input Points 8 (I1 to I8) 8 (I1 to I8) 8 (I1 to I8) 8 (I1 to I8) High-speed Input*1 4 (I3, I4, I5, I6), 5 kHz maximum 4 (I3, I4, I5, I6), 5 kHz maximum — — Analog Input Points 4 (I1, I2, I7, I8) 4 (I1, I2, I7, I8) — — Analog Input Range 0 to 10V DC (max. rated input: 28.8V DC) 0 to 10V DC (max. rated input: 28.8V DC) — — Analog Input Error ±1.5% (of full scale) ±1.5% (of full scale) — — Analog Input Resolution 10 bits (0 to 1000) 10 bits (0 to 1000) — — Cycle time 300 ms 300 ms 300 ms 300 ms Allowable Voltage Range 0 to 28.8V DC 0 to 28.8V DC 0 to 26.4V AC 0 to 28.8V DC 0 to 265V AC 0 to 253V DC Input Impedance Digital Input 5.8 kΩ 5.8 kΩ 4.8 kΩ 610 kΩ Analog Input 80 kΩ 80 kΩ — — Isolation — — — — Operating Range OFF Voltage < 5V DC < 5V DC < 5V AC/DC < 40V AC < 30V DC ON Voltage ≥ 12V DC ≥ 8.5 V DC ≥ 12V AC/DC ≥ 79V AC ≥ 79V DC OFF Current < 0.9 mA (I3 to I6) < 0.88 mA (I3 to I6) < 0.06 mA (DC) ON Current ≥ 2.1 mA (I3 to I6) ≥ 1.5 mA (I3 to I6) ≥ 0.13 mA (DC) Turn ON Time 1.5 ms (Typ.) ≤ 1.0 ms (I3 to I6) 1.5 ms (Typ.) ≤ 1.0 ms (I3 to I6) 1.5 ms (Typ.) 100V AC: 40 ms (Typ.) 240V AC: 30 ms (Typ.) 100V DC: 25 ms (Typ.) 240V DC: 20 ms (Typ.) Turn OFF Time 1.5 ms (Typ.) ≤ 1.0 ms (I3 to I6) 1.5 ms (Typ.) ≤ 1.0 ms (I3 to I6) 15 ms (Typ.) 100V AC: 45 ms (Typ.) 240V AC: 70 ms (Typ.) 100V DC: 60 ms (Typ.) 240V DC: 75 ms (Typ.) Wire Length 100m maximum (*2) 100m maximum (*2) 100m maximum (*2) 100m maximum (*2) Output Output Signal Transistor source output Relay output Relay output Relay output Output Points/ Contact Configuration 4 points (separate) 4NO contacts 4NO contacts 4NO contacts Isolation — Isolated Isolated Isolated Dielectric Strength (between power/input terminals and output terminals) — 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute Output Voltage External power voltage — — — Maximum Load Current 0.3A maximum Resistive load 10A at 12/24V AC/DC 10A at 100/120V AC 10A at 230/240V AC

0.2 A at 120V DC

0.1 A at 240V DC

Surge Current — 30A maximum 30A maximum 30A maximum Short-circuit Protection Built-in current limiting resistor: Approx. 1A External fuse required: 16A maximum External fuse required: 16A maximum External fuse required: 16A maximum Minimum Switching Load — 10 mA, 12V DC (reference value) 10 mA, 12V DC (reference value) 10 mA, 12V DC (reference value) Initial Contact Resistance — 100 mΩ maximum (at 1A, 24V DC) 100 mΩ maximum (at 1A, 24V DC) 100 mΩ maximum (at 1A, 24V DC) Mechanical Life — 10 million operations (no load, 10 Hz) 10 million operations (no load, 10 Hz) 10 million operations (no load, 10 Hz) Electrical Life — 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour After power-up, the FL1F takes a maximum of 1.2 seconds (when using a micro SD card) to RUN mode. *1) When selecting frequency trigger function. *2) 10m when connected to analog input (twisted pair cable) FL1F SmartRelay

Expansion I/O Module Specifications Expansion I/O Module Type No. FL1F-M08B1S2 FL1F-M08B2R2 FL1F-M08D2R2 FL1F-M08C2R2 FL1F-J2B2 FL1F-K2BM2 Power Supply Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 12/24V DC 24V DC 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC 10.8 to 28.8V DC 20.4 to 28.8V DC Rated Frequency — — 50/60Hz (47 to 63Hz) 50/60Hz (47 to 63Hz) — — Current Draw 25 to 40 mA 20 to 90 mA (12V DC) 15 to 50 mA (24V DC) 40 to 100 mA (24V AC) 15 to 50 mA (24V DC) 23 to 46 mA (100V AC) 15 to 30 mA (240V AC) 12 to 29 mA (100V DC) 5 to 15 mA (240V DC) 25 to 30 mA 30 to 82 mA Allowable Momentary Power Interruption — 2 ms (typ.) (12V DC) 5 ms (typ.) (24V DC) 5 ms (typ.) (24V AC/DC) 10 ms (typ) (100V AC/DC) 20 ms (typ.) (240V AC/DC) 10 ms (typ.) (12/24V DC) 10 ms (typ.) Power Consumption 1.0W 1.1W (12V DC) 1.2W (24V DC) 2.6W (24V AC) 1.2W (24V DC) 4.6W (100V AC) 7.2W (240V AC) 2.9W (100V DC) 3.6W (240V DC) 0.4W (12V DC) 0.7W (24V DC) 2.0W Reverse Polarity Protection Yes Yes — — Yes Yes Input Input Signal DC input DC input AC/DC input AC/DC input Analog input — Input Points 4 4 4 4 — — 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC — — Operating Range OFF Voltage < 5V DC < 5V DC < 5V AC/DC < 40V AC < 30V DC — — ON Voltage ≥ 12V DC ≥ 8.5V DC ≥ 12V AC/DC ≥ 79V AC ≥ 79V DC — — OFF Current < 0.88 mA < 0.88 mA < 1.1 mA < 0.05 mA (AC) < 0.06 mA (DC) — — ON Current ≥ 2.1 mA ≥ 1.5 mA ≥ 2.63 mA ≥ 0.08 mA (AC) ≥ 0.13 mA (DC) — — 100V AC: 40 ms (typ.) 240V AC: 30 ms (typ.) 100V DC: 25 ms (typ.) 240V DC: 20 ms (typ.) — — 100V AC: 45 ms (typ.) 240V AC: 70 ms (typ.) 100V DC: 60 ms (typ.) 240V DC: 75 ms (typ.) — — Analog Input Points — — — — 2 — Analog Input Range — — — — 0 to 10V (max. rated input: 28.8V) 0 to 20 mA (max. rated input: 40 mA) — Digital Resolution — — — — 10 bits (0 to 1000) — Input Error — — — — ±1.5% (of full scale) — Input Impedance — — — — 76 kΩ (0 to 10V) 250Ω (0 to 20mA) — Sampling Cycle — — — — 50ms — Output Wire Length 100m maximum 100m maximum 100m maximum 100m maximum 10m (twisted-pair shielded cable) — Output Signal Transistor source output Relay output Relay output Relay output — — Output Points/ Contact Configuration 4 points (separate) 4NO contacts 4NO contacts 4NO contacts — — Isolation — Isolated Isolated Isolated — — Dielectric Strength (between power/input terminals and output terminals) — 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute — — Output Voltage External power voltage Maximum Load Current 0.3A maximum Resistive load 5A at 12/24V AC/DC 5A at 100/120V AC 5A at 230/240V AC — — Short-circuit Protection Built-in current limiting resistor: Approx. 1A External fuse required: 16A maximum External fuse required: 16A maximum External fuse required: 16A maximum — Yes Minimum Switching Load — 10 mA, 12V DC (reference value) 10 mA, 12V DC (reference value) 10 mA, 12V DC (reference value) — — Initial Contact Resistance — 100 mΩ maximum (at 1A, 24V DC) 100 mΩ maximum (at 1A, 24V DC) 100 mΩ maximum (at 1A, 24V DC) — — Mechanical Life — 10 million operations (no load, 10 Hz) 10 million operations (no load, 10 Hz) 10 million operations (no load, 10 Hz) — — Electrical Life — 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour — — Analog Output Points — — — — — 2 Analog Output Range — — — — — Voltage: 0-10V DC Current: 0-20, 4-20 mA Digital Resolution — — — — — 10 bits (0 to 1000) Output Error (of full scale) — — — — — ±2.5% Output Impedance — — — — — Voltage: 5 kΩ minimum Current: 250Ω maximum Analog Value Conversion Interval — — — — — 50 ms (typ.) Wire Length — — — — — 10m (twisted-pair shielded cable) FL1F SmartRelay

Item Specifications Standard Operating Temperature Horizontal Mounting –20 to +55°C (no freezing) (*1) Cold: IEC60068-2-1 Hot: IEC60068-2-2Vertical Mounting –20 to +55°C (no freezing) (*1) Storage/ Transportation Temperature –40 to +70°C (no freezing) — Relative Humidity 10 to 95% (no condensation) IEC60068-2-30 Atmospheric Pressure 795 to 1080 hPa — Operating Condition No corrosive gas — Degree of Protection IP20 — Vibration Resistance 5 to 8.4 Hz, amplitude 3.5 mm 8.4 to 150 Hz, acceleration 9.8 m/s2 IEC60068-2-6 Shock Resistance 147 m/s2 IEC60068-2-27 Drop Test (packaged) 0.3m IEC60068-2-32 Emissions Limit class B Group 1 Conducted: 0.15 to 30MHz EN55011/A EN55022/B EN50081-1 Electrostatic Discharge Immunity 8 kV air discharge 6 kV contact discharge IEC61000-4-2 Radiation Field Immunity Field Strength: 1 V/m and 10 V/m IEC61000-4-3 Fast Transient Burst 2 kV (power line) 2 kV (I/O signal line) IEC61000-4-4 Surge Immunity (*2) (FL1F-H12RCC, FL1F-B12RCC only) 1 kV (power line) normal 2 kV (power line) common IEC61000-4-5 Communication Cable 2.5 mm2 (one wire) 1.5 mm2 (two wires) — Terminal Style Finger-safe type (*3) — *1) Base module: 0 to 55°C when FS is 04 or earlier Text display: 0 to 55°C when FS is 03 or earlier *2) For protection against surge noise on DC power supply types (FL1F-H12RCE/B12RCE, FL1F-H12SCD, FL1F-H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise filters. Use of a surge protection device (DEHN + SÖHNE GmbH + Co, BVT AD 24 Part No. 918 402) is recommended. *3) Tightening torque 0.5 to 0.6 N·m Text Display Specifications Power Voltage 24V AC/DC 12V DC Allowable Voltage Range 20.4 to 26.4V AC 10.2 to 28.8V DC Allowable Voltage Frequency 47 to 63Hz Power Consumption 12V DC: 150 mA (Typ.) 24V DC: 75 mA (Typ.) 24V AC: 145 mA (Typ.) (*1) Data Transmission Rate 10/100 M full/half duplex data transmission rate Display FSTN graphic display (W × H: 160 × 96 dots) LED backlight (White, Amber, Red) Font type English, Spanish, Russian, Chinese, Italian, Turkish, German, Dutch, French, Japanese Displayable string 1 screen 6 lines × 20 columns Keyboard Membrane keypad Installation Panel cut-out using mounting clips Dimensions (W × H × D) 128.2 × 86 × 38.7 mm *1) 75 mA when FS is 03 LCD Display / Backlight Backlight Durability (*1) 20,000 hours LCD Display Durability (*2) 50,000 hours *1) Backlight durability is the number of hours taken for the light to become 50% of the original brightness. *2) Display durability is calculated under ordinary operating and storage conditions: room temperature, normal humidity below 65% RH, and not subjected to direct sunlight. Dimensions All dimensions in mm. Mounting Hole Layout (Using Mounting Slides) /twosans/twosans/twosans/twosans/onesans/twosans/twosans/twosans 98 +/- 0.3 Text Display 77.6 38.7 34.7 31.9 128.2 (Panel Cutout) 119.0+0.5mm 78.5+0.5mm Mounting clip Mounting screws (tightening torque: 0.15 to 0.2 N·m) Panel (thickness: 1.5 to 4 mm) Mounting clip Gasket Base Module (with Display) 71.5 Base Module (without Display) 71.5 Expansion I/O Module 35.5  Base module  Expansion I/O module FL1F SmartRelay

FL1F-H12SCD/-H12RCE /-B12RCE FL1F-M08B1S2/-M08B2R2 I3 to I6 4.3k/uni03A9 47nF1.5k/uni03A9 4.7k/uni03A9 L+ (12/24V DC) OUT M I3 to I6 4.3k/uni03A9 47nF1.5k/uni03A9 4.7k/uni03A9 L+ (12/24V DC) OUT 0V M(0V) I3 to I6 NPN Output DC 3-wire Sensor M I3 to I6 PNP Output DC 3-wire Sensor Internal Circuit Internal Circuit When using a NPN output sensor, connect an external resistor (I3 to I6): FL1F-H12SCD: For power voltage 24V DC: R1≤ 4kΩ, 1/4W FL1F-H12RCE, -B12RCE For power voltage 24V DC: R1≤ 8.1kΩ, 1/4W For power voltage 12V DC: R1≤ 1.5 kΩ, 1/4W OUT M(0V) I1,I2 I7,I8 L+ (12/24V DC) 54.9k/uni03A9 20k/uni03A910nF M 1nF 5.1k/uni03A9 +3.3V I1,I2,I7,I8 NPN Output DC 3-wire Sensor Internal Circuit I1,I2,I7 and I8 accept both digital and analog inputs. The diagram above is for using I1,I2,I7, and I8 as digital inputs. When using a NPN output sensor, connect an external resistor (I1,I2,I7,I8): FL1F-H12SCD: For power voltage 24V DC: R2≤ 50kΩ, 1/8W FL1F-H12RCE, -B12RCE For power voltage 24V DC: R2≤ 100kΩ, 1/8W For power voltage 12V DC: R2≤ 19kΩ, 1/8W 24V AC/DC Input FL1F-H12RCA /-B12RCA FL1F-M08D2R2 I1 to I8 P1 (24V DC) OUT P2 (0V) 4.3k/uni03A9 100nF 510/uni03A9 I1 to I8 PNP Output DC 3-wire Sensor I1 to I8 P2 (24V DC) P1 (0V) I1 to I8 P1 (0V) OUT NPN Output DC 3-wire Sensor AC 2-wire Sensor I1 to I8 24V AC 4.3k/uni03A9 100nF 510/uni03A9 Internal Circuit Internal Circuit Bleeder resistance (R3) calculation R3 must satisfy the following three conditions. Condition 1: R3 (Ω) ≤ Maximum input OFF voltage (= 5VAC) Maximum sensor leakage corrent (A) Condition 2: R3 (Ω) ≤ Sensor power voltage (V) Maximum sensor load corrent (A) The voltage drop across the load (R3) must be less than 5V while the sensor is turned off. Condition 3: PR3 (W) ≤ {Sensor power voltage (V)}2 R3 resistance (Ω) × 3 (3: recommended allowance) 100 to 240V AC/DC FL1F-H12RCC /-B12RCC FL1F-M08C2R2 I1 to I8 N 100 to 240V AC 390k/uni03A9 120nF 43k/uni03A9 180k/uni03A9 270k/uni03A9 I1 to I8 Internal Circuit AC 2-wire Sensor Bleeder resistance (R4) calculation R4 must satisfy the following three conditions. Condition 1: R4 (Ω) ≤ Maximum input OFF voltage (= 40VAC) Maximum sensor leakage corrent (A) Condition 2: R4 (Ω) ≤ Sensor power voltage (V) Maximum sensor load corrent (A) The voltage drop across the load (R4) must be less than 40V while the sensor is turned off. Condition 3: PR4 (W) ≤ {Sensor power voltage (V)}2 R4 resistance (Ω) × 3 (3: recommended allowance) FL1F SmartRelay

U1,U2 57k/uni03A9 10nF19k/uni03A9 +3.3 Internal Circuit 0 to 10V M1, M2 Internal Circuit Analog Current Input FL1F-J2B2 I1,I2 M1,M2 0 to 20mA Max.55/uni03A9 10nF124/uni03A9 Internal Circuit Use a twisted pair cable, and keep the cable as short as possible. Output Internal Circuits Relay Output FL1F-H12RCE/-B12RCE/-H12RCA/-B12RCA/-H12RCC/-B12RCC FL1F-M08B2R2/-M08D2R2/-M08C2R2 Internal Circuit L 240V AC/24V DC Fuse Load +V Internal Circuit Q1 to Q4 N, M L1 L+ DC Output (Transistor Source Output) FL1F-H12SCD FL1F-M08B1S2 Internal Circuit IN OUT +24V Internal Circuit Q1 to Q4 M L Load24V DC 0.3A max.10nF 100k/uni03A9 When connecting to a DC input type PLC, use a negative common sink input type. Analog Voltage Output FL1F-K2BM2 (0-10V DC) Internal Circuit U1+,U2+ M1,M2 +15V Internal Circuit 10/uni03A9 100nF Analog Current Output (0-20, 4-20 mA) I1,I2 M1,M2 +15V Internal Circuit 22/uni03A9 10nF Internal Circuit FL1F SmartRelay

Q AND (Edge) Edge detection with edge evaluation (pos. edge) Q 1234 56 78 91 0Cycle Q AND NAND Parallel connection of normally closed contacts Q NAND (Edge) Edge detection with edge evaluation (pos. edge) Q 12 34 56 78 91 0Cycle NAND Q OR Parallel connection of normally open contacts Q NOR Series connection of normally closed contacts Q XOR Double changeover contact Q NOT Connection of closed contact Q Special Function Blocks On-delay QQ TrgTrg Par T Off-delay Q Q Trg R Par Trg R T On-/Off- delay Q Q Trg Par Trg TH TL Retentive on-delay QQ Trg R Par Trg R T T Latching Relay RSS R Q Q S R Par Current impulse relay Q Trg R RS S ParQ Trg R S Interval time- delay relay/Pulse output QQ Trg Par Trg T Edge- triggered interval time-delay relay Q Trg Par R Tr g Q T HL TT T HL Seven-day time switch Q Q No1 No2 No3 No1 No2 Sa Su 1212 20 20 12 20 82 0 8 22 Sa Su Su ON 12:00 OFF 20:00 ON 8:00 OFF 22:00 Twelve- month time switch No 02.25 No 04.15 Q Q No MM DD MM.DDt Fed. Mar. Apr. 25 25 Up/down counter Q Q Cnt R Dir Par Cnt Dir Par R Analog filter Sn=8 AQ AX Sn 1 2 3 4 5 6 7 8 9 10 ... Sn=8 Sn=8Sn=8Sn=8Sn=8Sn=8 Astronomical clock Monday TR TS TR TS TR TS Q Tuesday Wednesday... TaTa Ta AC Q Analog differential trigger Q Ax ParQ AX OFF=On+ on Q AX OFF=On+ Analog value monitor Q En Ax Par Q AX En Aen+ Aen-Aen Operating hours counter Q Q En R Ral Par En Ral R h MN=MI OT MN=0 Asynchronous pulse generator En Inv Q Q En Par Inv TH TL Random generator Q Q En Par Trg T Starts TH TL Frequency trigger Fre G-T Q Q Fre Par fa=5Hz fa=3Hz 1s 1s Analog trigger 1000 SW SW 0A/1 or A/2 Q Q Ax Par Analog comparator 1000 A/1 0 1000 A/2 0 Q Q Ax Ay Par 1000 200 -200 A/1-A/2 0 tor =200 Stairwell light switch T Starts Q Q Trg Par Trg T 15s Dual- function switch Q Trg Par RQ TLTL TIL T Trg Max/Min Ax 300 300 200 300 200 100 100 250 250 380 380 350 100 AQ Mode En (If ERst=1) Ax AQ En Ax Stopwatch En R AQ LapT CurT Lap Sw AQ En Lap R Message texts Par Q En P Softkey Q En Par Q Switch En Analog amplifier AQ Ax Par Enhanced Shift register Q Trg In Dir R Par S1.1 S1.2 S1.3 S1.4 S1.5 S1.6 S1.7 S1.8 Shift Up Shift Down S4=Q (Example) In Q R Dir Trg PI control AQ A/M R Par PV 500 ms A/M R Dir Max SP Min Mq Q PV AQ 1 2 3 Analog ramp control AQ En Sel Par St En Sel Level 2 Level 1 Rate RateRate St AQ StSp+B 100 ms 100 ms 100 ms MaxL B Rate Analog multiplexer En 0 AQ AQ En Par Pulse width modulator (PWM) Ax Par Q En En Max =1000 Ax = 500 Min = 0 Q Analog math AQEn Par Analog math error detection Q En R Par Average value Sn=8 St=10s Sn=8 St=10s AX En R AQ Sn 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Ax AQ En R Ax Float to integer conversion F/IPar Integer to float conversion I/F Ax Par Ax AQAx FL1F SmartRelay

Base Module connects up to 12 Expansion I/O Modules and maximum 60 I/0s can be used according to the combinations shown below. 1. For the terminal arrangement and wiring of the module, please be sure to read FL1F user’s manual. 2. Before connecting and disconnecting modules, turn power off. 3. A maximum of 24 digital inputs, 8 analog inputs, 20 digital outputs, 8 analog outputs can be used by using a combination of a Base Module and Expansion I/O Modules. 4 When using modules of the same power voltage, supply power to the Base Module and Expansion I/O Modules using one power supply. When suplying power to the modules using different power supplies, supply power to the Base Module and Expansion I/O Module at the same time. Or, supply power to the Expansion I/O Module before the Base Module. Expansion I/O module may not be recognized if power is supplied to the Expansion I/O Module after the Base Module. When power is supplied to the modules from different power supplies, the fast transient burst is 1 kV (IEC61000-4-4). 5. A 100 to 240V AC/DC module cannot be connected to the right side of a 12/24V DC, 24V DC, or 24V AC/DC module. 6. For optimal and high-speed communication performance between Base Module and Expansion I/O Modules, install the input/output modules first, then the analog modules. 7. Approvals are as follows: ABS: American Bureau of Shipping (USA) BV: Bureau Verites (France) DNV GL: (Norway) LR: Lloyd’s Register of Shipping (UK) NK: (Japan) 8. The following are the conditions of marine standards approval.

  • Modules of rated power voltage 12/24V AC/DC: Use at 24V DC
  • Modules of 12/24V DC and 24V DC: Use a surge protection device Part no. 918 402/918 422 made by DEHN+SÖHNE or equivalent.
  • For applications on a bridge or decks, a noise filter Part no. B84113-C-B-30 (made by TDKEPCOS) or equivalent is used (FL1F-RD1 cannot be used on a bridge or deck).
  • Contact IDEC regarding the environment where FL1F can be used. Wiring Base Module and Expansion I/O Module
  • Connect an IEC60127 approved fuse to the power supply for protec- tion against overload and short circuit.
  • Do not connect input wire and communication cable in parallel or near the power line, output line, or motor line. Also make sure that any noise source is not present nearby. Power-up
  • After power-up, FL1F takes a maximum of 1.2 seconds (when using a micro SD card) to RUN mode. During power-up, a timer appears on models with a display. When using the FL1F without display, the red LED flashes, then the green LED flashes when RUN mode starts.
  • Time taken to change to RUN mode 1.2 seconds maximum www.idec.com USA IDEC Corporation Tel: +1-408-747-0550 opencontact@idec.com Germany APEM GmbH Tel: +49-40-25 30 54 - 0 service@eu.idec.com Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155 info@sg.idec.com Thailand IDEC Asia (Thailand) Co., Ltd Tel: +66-2-392-9765 sales@th.idec.com Australia IDEC Australia Pty. Ltd. Tel: +61-3-8523-5900 sales@au.idec.com Taiwan IDEC Taiwan Corporation Tel: +886-2-2698-3929 service@tw.idec.com China/Shanghai IDEC (Shanghai) Corporation Tel: +86-21-6135-1515 idec@cn.idec.com China/Shenzhen IDEC (Shenzhen) Corporation Tel: +86-755-8356-2977 idec@cn.idec.com China/Beijing IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com Japan IDEC Corporation Tel: +81-6-6398-2527 marketing@idec.co.jp Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan
  • Ethernet is a registered trademark of Xerox Corporation.
  • Microsoft Excel® is a trademark of US based Microsoft Corporation in the United States and other countries.
  • All trademarks and registered trademarks described in this catalog are the property of their respective owners.
  • Speci/f_ications and other descriptions in this brochure are subject to change without notice.
  • Information in this catalog is current as of February, 2019. EP1562-2 2019 IDEC Corporation, All Rights Reserved. FL1F SmartRelay