FF01 Series(Φ25,Φ30) Low Profile E-STOP Switches Innovation Driving Quality Low Profile E-STOP Switches Only 13.6mm Behind-Panel Shortest E-Stop Switch in its Class CONTACT No. 360 New Products FF01 Series Low Profile E-STOP Switches NKK SWITCHES CO., L TD. Innovation Driving Quality

Two Reset Methods: Pull or Turn Switch can be reset either by pulling or turning. Behind-Panel Depth of 13.6 mm The sliding latch mechanism achieves the industry’s shortest behind-panel depth in its Class.* The low-profile housing enables high density behind-panel layouts. * (Industry’s shortest body length including terminals as of November 2019, based on in-house research) ɾUL , C-UL (UL508) ɾEN60947-5-1, EN60947-5-5 Sliding Latch Mechanism Our original sliding latch mechanism features an inclined switch center section for the latch to maintain secure current contact. When the contact is in ON position, this mechanism permits only forces in the contact connecting direction. When OFF, the mechanism permits only forces in the contact releasing direction. In the event of vibration or impact, the contact will resist movement in the connecting direction, thereby maintaining the OFF state for added safety. (Patent pending) Rating 24 V DC, 0.5 A Front Panel Seal Structure The front panel sealing mechanism meets the IEC 60529 IP65 requirements. Actuator Size Just 25 mm in Diameter Measuring only 25 mm in diameter, the small actuator allows installation on a densely embedded panel. Actuators are available in 25 mm or 30 mm diameter to enable low-profile equipment and space- saving installation. Only 13.6mm Behind-Panel Depth - Shortest E-Stop Switch in its Class* Portable equipment and handheld devices, including compact remote controls (teaching pendants) If you need further information on standards or certifications, please contact our sales department.

Applications

May 12, 2020 FF01 Series Low Profile E-STOP Switches www.nkkswitches.eu mm13.6 Industry’s Shortest Depth in Class 30 mm type25 mm type NN 25 30 Ϋϥε mmmm Ϋϥε ΈάϧʔϓԽͯ͠ͳ͍ Pull to reset Turn to reset NN 25 30 Ϋϥε mmmm Ϋϥε ΈάϧʔϓԽͯ͠ͳ͍ Pull to reset Turn to reset NN 25 30 Ϋϥε mmmm Ϋϥε ΈάϧʔϓԽͯ͠ͳ͍ Pull to reset Turn to reset

Resistive load: 24 V DC, 0.5 A * UL, TÜV certified rating Nominal Operating Force 15 N Rated Insulation Voltage 36 V DC Pretravel 3 mm Rated Withstand Impulse Voltage 2.5 kV Total Travel Approx. 4.5 mm Sealing Front panel: IP65 Contact Resistance 50 mΩ maximum (initial value) Pollution Degree 3 Insulation Resistance 100 MΩ (at 500 V DC) Short-circuit gG 10 A Overvoltage Category II Conditional Short-circuit Current 1000 A Operation Frequency 10 times/min. Operating Temperature Range -25 to 60°C Shock Resistance Durability: 1,000 m/s Malfunction: 150 m/s Storage Temperature Range -45 to 80°C Operating Force (Initial Value) Push to lock: 10.8 N Pull to reset: 8.5 N Turn to reset: 0.13 N·m Vibration Resistance Durability: 10 to 500 Hz, half amplitude: 0.35 mm, acceleration: 50 m/s Malfunction:10 to 500 Hz, half amplitude: 0.35 mm, acceleration: 50 m/s Contact Point N/C Mechanical /Electrical Life Mechanical, electrical: 100,000 operations minimum (resistive load), 6,050 times minimum (inductive load (DC-13)) Soldering Soldering: 390°C maximum, within 4 seconds Recommended fixing nut mounting torque 785 mN·m TYPICAL SWITCH ORDERING EXAMPLE FF01 Series Low Profile E-STOP Switches www.nkkswitches.eu '' B C A01 Poles

1 SPST

2 DPST

6 Latchdown

/Terminal Shape A01 Gold over Silver /Solder Lug A EA * UL, TÜV certified rating

  • UL certified rating: 24 V DC, 0.5 A (inductive load)
  • TÜV certified rating: 24 V DC, 0.5 A (inductive load) * Minimum applicable load (reference value): 5 V DC, 1 mA (Usage conditions and load types may affect the allowable operating range.) 25mm Actuator 30mm Actuator Poles No Legend Arrows Legend No Legend Arrows Legend SPST FF0116BACEEA01 FF0116BACAEA01 FF0116BBCEEA01 FF0116BBCAEA01 DPST FF0126BACEEA01 FF0126BACAEA01 FF0126BBCEEA01 FF0126BBCAEA01 External view

www.nkkswitches.eu FF01 Series Low Profile E-STOP Switches (25mm) Double Pole Single Throw (DPST) Single Pole Single Throw (SPST) Plunger Position Model Connected Terminals Poles No Legend Arrows Legend SPST ON OFF FF0116BACEEA01 FF0116BACAEA01 11-12 - DPST ON OFF FF0126BACEEA01 FF0126BACAEA01 11-12 21-22 - The switch can be reset in two different ways (push to lock, pull or turn to reset). 9.4 t0.5 2.5 2.8 20.6 10 3.625 Dia M16P1 Anti-rotation Tab side Enlarged view of terminal sections (2:1) Anti-rotation Tab side Arrows Legend

25 Dia

9.4 t0.5 2.8 20.6 10 3.625 Dia M16P1 terminal sections (2:1) Anti-rotation Tab side Arrows Legend Typical Switch Dimensions Mounting Panel Cutout Recommended Panel Thickness 0.8 to 4.5 mm +0.2 1.70 +0.2 +0.2 17.90

www.nkkswitches.eu FF01 Series Low Profile E-STOP Switches (30mm) Double Pole Single Throw (DPST) Single Pole Single Throw (SPST) Plunger Position Model Connected Terminals Poles No Legend Arrows Legend SPST ON OFF FF0116BBCEEA01 FF0116BBCAEA01 11-12 - DPST ON OFF FF0126BBCEEA01 FF0126BBCAEA01 11-12 21-22 - The switch can be reset in two different ways (push to lock, pull or turn to reset).▲ Typical Switch Dimensions Mounting Panel Cutout Recommended Panel Thickness 0.8 to 4.5 mm +0.2 1.70 +0.2 +0.2 17.90 3.61020.6 M16P1

30 Dia

9.4 t0.5 2.5 2.8 FF0116BBCAEA01 FF0116BBCEEA01 Anti-rotation Tab side Enlarged view of terminal sections (2:1) Anti-rotation Tab side Arrows Legend 3.61020.6 M16P1 9.4 t0.5 2.8 FF0126BBCAEA01 FF0126BBCEEA01 Anti-rotation Tab side Enlarged view of terminal sections (2:1) Anti-rotation Tab side Arrows Legend

FF01 Series Low Profile E-STOP Switches www.nkkswitches.eu Nameplate (Sold Separately) Model Specification Mounting Panel Cutout Base Color: Yellow Legend Color: Black AT221 No Legend Panel Thickness: 0.5 to 3.0 mm AT222 EMERGENCY STOP Positional relationship between mounting hole (shown in above diagram) and Arrows Legend on actuator Accessories +0.2 1.7 0 +0.2 +0.2 17.9 0 &.&3(&/$: 4501 Fixing Nut Wrench (Sold Separately) AT119 "5 "5 O 㶌 t 1.65 43.5 16.1 &.&3(&/$: 4501 ࢭ "5 "5 O 㶌 t 1.65 43.5 16.1 &.&3(&/$: 4501 ࢭ Protective Guard (Sold Separately) Mounting Panel Cutout Positional relationship between mounting hole (shown in left diagram) and Arrows Legend on actuatorAT220 Panel Thickness: 0.5 to 3.0 mmColor: Yellow +0.2 1.7 0 +0.2 +0.2 17.9 0 O 㶌 t 0.5 15.8 5031 22.9 12.1

FF01 Series Low Profile E-STOP Switches www.nkkswitches.eu Instructions for AT220 Protective Guard The product conforms to SEMI S2 / ISO13850. Please read the instructions carefully to ensure correct product use. Safety Precautions

  • The protective guard is made exclusively for use with NKK’s FF01 Series and should not be used with other types of products.
  • Read the FF01 Series Instruction Manual before switch installation, cable connection, operation, maintenance or inspection.
  • Confirm power is off before installation, cable connection, maintenance, etc.
  • When installing product on other equipment, be sure usage is in compliance with standards and regulations of your country or region, as required for your system, equipment or facility. Installation to Panel (1) Remove the nut from the switch body. (2) Insert the switch body into the protective guard from the front of the guard, aligning notch on the O-ring with the anti-rotation tab on the switch body. Align the anti-rotation tab on the switch body with the keyway on the guard. (3) Align the anti-rotation tab on the back of the guard with the anti-rotation keyway on the panel. (4) Using the AT119 Fixing Nut Wrench, tighten the nut from the back of the panel (recommended torque 785mN•m). Installation Height The switch must be installed within 3 meters from the working position. (SEMI S2) To install the switch with the protective guard onto semiconductor manufacturing equipment, the mounting height range should be 838 mm to 1,638 mm. The horizontal reach (maximum) should be between 178 mm and 254 mm. (SEMI S8) Horizontal reach Installation Height Front end of equipment Anti-rotation Keyway on Protective Guard Anti-rotation Tab on Protective Guard Anti-rotation Keyway on Panel Notch on O-ring Anti-rotation Tab on Switch Body Installation Height 1638 mm (64.5 in.) 1524 mm (60.0 in.) 1422 mm (56.0 in.) 1321 mm (52.0 in.) 1219 mm (48.0 in.) 1118 mm (44.0 in.) 1016 mm (40.0 in.) 914 mm (36.0 in.) 838 mm (33.0 in.) Horizontal reach (max.) 254 mm (10.0 in.) 368 mm (14.5 in.) 432 mm (17.0 in.) 470 mm (18.5 in.) 483 mm (19.0 in.) 470 mm (18.5 in.) 394 mm (15.5 in.) 292 mm (11.5 in.) 178 mm ( 7.0 in.) * To be in compliance with the SEMI standard, it is necessary that EMO (Emergency Off) is printed on the switch or on the inside of the guard. * To confirm that the switch and protective guard mounted on a device are ISO compliant, see requirements of ISO13850. To install the switch with the protective guard on equipment such as machine tools or processing equipment, the recommended height range is between 600 mm and 1,700 mm from the floor or platform level (ISO13850). (SEMI S8)

Published May 12, 2020 * The specifications in this document are subject to change without notice. For the latest specifications, please contact our local representative. &VSPQFBO0GpDF .FSHFOUIBMFSBMMFF &TDICPSO (FSNBOZ 5FM &OHMJTI (FSNBO XXXOLLTXJUDIFTFVɹ&NBJMDPOUBDU!OLLTXJUDIFTFV FF01 Series Low Profile E-STOP Switches Safety Precautions Caution in Use Usage Environment Routine Care Installing the Switch

  • When the product is installed on other equipment, be sure usage is in compliance with all applicable standards and regulations in the country or region, as required for the system, machine, or facility.
  • Be sure to read the instruction manual and catalog before installing, wiring, operating, maintaining, or inspecting the product. Before using the product
  • Do not use a power supply that exceeds the rated voltage or current indicated in the specifications. Using a power supply that exceeds ratings may cause overheating or fire.
  • Use wires of appropriate rating. Use of improper wires may cause overheating and fire.
  • Follow recommended “Mounting Panel Cutout” dimensions and installation instruction, or switch may be fixed loose and not operate properly.
  • Remove dirt and dust from the switch mounting surface of the panel before installation.
  • Do not disassemble the product as it may cause electric shock, fire, or malfunctions.
  • Confirm power is off before installation, wiring, maintenance, or inspections. Failure to do so may cause electric shock, fire, or malfunctions.
  • Operate the product by hand only. Do not operate using foot, tool, or other objects.
  • Chattering and bouncing Bouncing may occur during a reset operarion (pull or turn to reset). Chattering may occur if the equipment the switch is mounted on is subjected to shock or vibration. Take appropriate measures to prevent chattering and bouncing on the equipment side.
  • Safeguard against excessive shock or vibration, such as dropping. Excessive shock and vibration may result in deformation, damage, degraded performance, or failure. Soldering
  • After inserting the lead wire into the terminal hole, use a soldering iron to ensure a secure connection. Incomplete soldering may cause overheating and fire during use.
  • Note that if soldering is performed while the terminal is facing up, the flux may enter the interior of the switch. Perform soldering carefully.
  • The solder resistant temperature is 390°C. Complete the soldering within four seconds.
  • The product is designed for indoor use.
  • Do not install in locations subject to frequent splashing water.
  • If the product becomes wet, wipe off with a dry cloth. Using a switch exposed to water may result in water entering inside. If the water freezes inside the switch, it may not function properly.
  • When using the product in environments subject to accumulations of dust and dirt, remove such accumulations from the area around the switch before use. Accumulated dust and dirt, may affect switch function.
  • Use a dry cloth to wipe dirt from the actuator. If the actuator is very dirty, wipe with a cloth dampened with a small amount of neutral detergent, then wipe dry. (Actuator material: Fiber- reinforced PBT) (1) Remove the round nut from the switch main body. (2) With the notch in the O-ring aligned with the anti-rotation tab on the switch main body, insert the switch body into panel. In this step, align the anti-rotation tab on the switch main body with the anti-rotation keyway on the panel. (3) Using the fixing nut wrench (AT119), tighten the round nut from the back side of the panel to the recommended tightening torque of 785 mN·m. Anti - rotation Tab on Switch Body Notch on O-ring Anti - rotation Keyway on Panel