FELCOM54 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Power Entry Modules with Line Filter Felcom 54https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 Modular Assembling Options Snap-in version 5411.XX5X.XXX Appliance inlet Fuseholder Line filter 5431.X05X.XXX Appliance inlet Appliance outlet Switch Line filter Approvals and Compliances C14 70° C F 70° C
Description
- Panel Mount : Snap-in version from front side - 2 - 5 Functions : Appliance Inlet Protection class I , Connector , Line Switch 2-pole , Fu- seholder for fuse-links 5 x 20 mm 1- or 2-pole , Line filter in standard and medical version - Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm Characteristics - Modular component selection - Individual components soldered on a printed circuit board - Plug removal necessary for fuse-link replacement - Technical data of filter-components see blockfilter type 5500 - Fully insulated from the rear - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Line switch with other rocker marking References Alternative: version without line filter Felcom 64 Alternative: Standard version Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Terminal Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm /2/2.5/3 mm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 acc. to IEC 60320-1, F acc. to UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Line Filter Standard Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 1'400'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals
Power Entry Modules with Line FilterFelcom 54 https://www.schurter.com /PG06 EMC Products Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: Felcom Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 101307 UL Approvals UL UL File Number: E72928 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the en- hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
Power Entry Modules with Line Filter Felcom 54https://www.schurter.com /PG06 EMC Products Dimensions [mm]
64.2 A1)
+0.30 Variants 5411.XX5X.XXX Mounting hole: 63 +0.2 x 27,6 +0.2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm
85.8 A1)
+0.30 Variants 5421.X05X.XXX Mounting hole: 85.9 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm
96.3 A1)
+0.30 Variants 5423.XX5X.XXX Mounting hole: 96.4 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 89.3 1) 10 10 +0.30 Variants 5424.XX5X.XXX Mounting hole: 87.9 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm
111.0 A1)
+0.30 Variants 5431.X05X.XXX Mounting hole: 111.1 +0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts.
Power Entry Modules with Line FilterFelcom 54 https://www.schurter.com /PG06 EMC Products ±0.20 121.5 1) A 10 10 +0.30 +0.30 S +0.50 0 5.5 +0.30 323 +0.50 Variants 5432.XX5X.XXX Mounting hole: 121.6+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts. Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2 x 4 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 -
1 Medical Version (M5) 2 x 11 47 - 1
2 Medical Version (M5) 2 x 4 47 - 1
4 Medical Version (M5) 2 x 1.6 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1
Power Entry Modules with Line Filter Felcom 54https://www.schurter.com /PG06 EMC Products Diagrams 5411 2)Cx Cy Cy 1) Line 2) Load 1 5421 2)1) L LINE N Cx Cy Cy 1) Load 2 2) Load 1 5423 2)1) L LINE N Cx Cy Cy 1) Load 2 2) Load 1 5424 2)Cx Cy Cy 1) Line 2) Load 1 5431 2)1) L LINE N Cx Cy Cy 1) Load 2 2) Load 1 5432 2)1) L LINE N Cx Cy Cy 1) Load 2 2) Load 1 Derating Curves 1-pole Admissible power acceptance in Watt02 04 06 08 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-pole Admissible power acceptance in Watt 02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C
Power Entry Modules with Line FilterFelcom 54 https://www.schurter.com /PG06 EMC Products Ordering instructions 54 XX.X X XX.X XX Base model Type of line filter 1 = standard 3 =m edical “Snap-in” panel thickness 10 = 1,0 mm 12 = 1,2 mm 15 = 1,5 mm 20 = 2,0 mm 25 = 2,5 mm 30 = 3,0 mm Connection 51 =s older terminals 3,5 x 0,8 mm 53 =q uick connect terminals 6,3 x 0,8 mm Fuseholder 5 x 20 mm 0 =w ithout fuseholde r 1 =1 -pole 2 =2 -pole Line filter 1 =1 Amp. 2 =2 Amp. 4 =4 Amp. 6 =6 Amp. 8 =8 Amp. 9 =1 0 Amp. Module combinatio n 11 =A ppliance inlet, fuseholde r 21 =A ppliance inlet, appliance outle t 23 =A ppliance inlet, fuseholde r, appliance outlet 24 =A ppliance inlet, fuseholde r, switch 31 =A ppliance inlet, appliance outlet, switc h 32 =A ppliance inlet, fuseholde r, appliance outlet, switch All Variants Type Rated Cur- rent [A] Filter-Type Panel Thick- ness s [mm] connection type Line Switch Fuseholder Connectors Connector Order Number Felcom 54 1 Medical Version (M5) Felcom 54 1 Medical Version (M5) Felcom 54 1 Medical Version (M5) Felcom 54 1 Medical Version (M5)
Power Entry Modules with Line Filter Felcom 54https://www.schurter.com /PG06 EMC Products Type Rated Cur- rent [A] Filter-Type Panel Thick- ness s [mm] connection type Line Switch Fuseholder Connectors Connector Order Number Felcom 54 2 Medical Version (M5) Felcom 54 2 Medical Version (M5) Felcom 54 2 Medical Version (M5) Felcom 54 2 Medical Version (M5) Felcom 54 4 Medical Version (M5) Felcom 54 4 Medical Version (M5) Felcom 54 4 Medical Version (M5) Felcom 54 4 Medical Version (M5) Felcom 54 4 Medical Version (M5)
Power Entry Modules with Line FilterFelcom 54 https://www.schurter.com /PG06 EMC Products Type Rated Cur- rent [A] Filter-Type Panel Thick- ness s [mm] connection type Line Switch Fuseholder Connectors Connector Order Number Felcom 54 6 Medical Version (M5) Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Accessories Cord retaining strain relief Flat head, A 4700.0001 Mating Inlets/Plugs Category / Description Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Straight 9009 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 Plug further types to Felcom 54 ... Mating Outlets/Connectors Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to Felcom 54 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to Felcom 54 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 14.12.2017