FCPM-6000RC MINI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
FCPM-6000RCIntegrated Frequency Counter & Power Meter Key Features Feature Advantages Ethernet-TCP/IP- HTTP and Telnet Protocols (Supports DHCP and Static IP) The FCPM-6000RC integrated freq. counter & power meter can be controlled from any Windows ®, or Linux® computer, or even a mobile device with a network connection and Ethernet-TCP/IP (HTTP or Telnet protocols) support. Using a VPN would allow remote control from anywhere in the world. USB control User may also control the integrated freq. counter & power meter via USB connection. Plug-and- Play, no driver required. Compatible with Windows ® or Linux® operating systems using 32 and 64 bit architecture (up to 24 sensors simultaneously). GUI program with USB and Ethernet interfaces Allows quick and easy measurement, average measurements, data recording, and more. ‘Measurement Application’ GUI software built-in Automated measurement setups which allow the user to perform measurements on RF components such as Couplers, Filters, Amplifiers, etc., display numerical data and graphs, and analyze the data. LCD character display LCD character display providing the frequency and power readings, as well as information on the unit’s status. Operates with external or internal reference The FCPM-6000RC can operate either synchronized with an external 10 MHz reference signal or independently, using its internal reference depending on user preference. No calibration required before taking measurement The FCPM-6000RC does not require any reference signal for calibration, reducing test time and simplifying operation. 5V power supply Powered via USB plug from PC, supplied AC adapter or from commercially available Power Over Ethernet (PoE) splitter with 5V output. Product Overview Mini-Circuits’ FCPM-6000RC Integrated Frequency Counter & Power Meter is a compact (5.00 x 2.66 x 1.36”) precision test device controlled via USB or Ethernet (HTTP and Telnet protocols) or operated as standalone test instrument. It simplifies test setups by enabling synchronized frequency and power measurements from a single device. The unit features an LCD display allowing convenient readings directly off the measurement head, while our user-friendly GUI software enables easy remote test management via USB or Ethernet. It comes supplied with Mini-Circuits’ GUI software, DLLs for programmers, user guide, programming instructions, and all the accessories needed for immediate use right out of the box (see page 8 for a complete list of included accessories). USB / Ethernet Trademarks: Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Tor- valds. Mac is a registered trademark of Apple Corporation. Pentium is a registered trademark of Intel Corporation. Neither Mini-Circuits nor the Mini-Circuits FCPM- 6000RC are affiliated with or endorsed by the owners of the above referenced trademarks Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. The Big Deal
- Automatically synchronized power & frequency measurements
- USB and Ethernet control
- Includes GUI with measurement applications software, simplifying complex measurements
- Measurement speed 30ms CASE STYLE: JL2029 Installation CD 50Ω -30 dBm to +20 dBm, 1 MHz to 6000 MHz
Integrated Frequency Counter & Power Meter Mini-Circuits Program for Integrated Frequency Counter & Power Meters Rev. C M155002 EDR-11250 FCPM-6000RC RAV 160828 50Ω 1 MHz to 6000 MHz Product Features
- USB and Ethernet control
- Supports HTTP and Telnet network protocols
- Wide bandwidth, 1 to 6000 MHz
- Uses external or internal reference
- LCD character display
- 50 dB Dynamic Range, -30 to +20 dBm
- Good VSWR, 1.1:1 typ.
- Fast measurement speed, 30 ms (power), 100 ms (freq).
- Automatic frequency calibration & temperature compensation
- Multi-sensor capability (up to 24)
- Built in ‘Application Measurement’ software
- User-friendly Windows ® Graphical User Interface
- Supports a wide range of programming environments (See application note AN-49-001 for details) Typical Applications
- Production testing systems
- Field testing
- Remote location monitoring
- Automatic, scheduled data collection
- Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools FCPM-6000RC RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications USB / Ethernet For programming instructions, see programming manual on Mini-Circuits’ website. For installation instruction and overview of FCPM-6000RC functions, see user guide on Mini-Circuits’ website. CASE STYLE: JL2029 Installation CD Included Accessories Model No. Description Qty. USB-AC/DC-5 AC/DC 5V Adapter 1 USB-RJ45-CBL-7+ 6.6 ft “Y” data cable (USB & RJ45) 1 FCPM-CD Installation CD 1
FCPM-6000RCIntegrated Frequency Counter & Power Meter Parameter Freq. Range (MHz) Min. Typ. Max. Units Dynamic range 2,3,4 @ 25ºC 1 - 5700 -30 − +20 dBm5700 - 6000 -28 − +20 @ 0ºC to 50ºC 1 - 6000 -27 − +20 VSWR 1 - 6000 − 1.05 1.25 :1 Uncertainty of Power Measurement @ 25ºC @ -30 to +5 dBm 5,6 1 - 3000 − ± 0.10 ± 0.30 dB 3000 - 6000 − ± 0.15 ± 0.30 dB @ +5 to +15 dBm 1 - 3000 − ± 0.15 ± 0.30 dB 3000 - 6000 − ± 0.15 ± 0.30 dB @ +15 to +20 dBm 1 - 3000 − ± 0.20 ± 0.40 dB 3000 - 6000 − ± 0.20 ± 0.40 dB Uncertainty of Power Measurement @ 0ºC to 50ºC @ -30 to +5 dBm 5,6 1 - 3000 − ± 0.25 − dB 3000 - 6000 − ± 0.25 − dB @ +5 to +15 dBm 1 - 3000 − ± 0.20 − dB 3000 - 6000 − ± 0.20 − dB @ +15 to +20 dBm 1 - 3000 − ± 0.35 − dB 3000 - 6000 − ± 0.30 − dB Power Linearity @ 25ºC 1 - 6000 − ± 3.0 − % Power Resolution 1 - 6000 0.01 − − dB Frequency Resolution 1 - 40 MHz − 1 − Hz40-190 MHz − 10 − 190-6000 MHz − 100 − Frequency Uncertainty (@1 sec measurement sample time) 4,7 1 - 40 MHz − ±2 − Hz 40-190 MHz − ±20 − 190-1400 MHz − ±200 − 1400 - 6000 MHz − ±800 − Averaging Range 1 - 6000 1 − 999 − Frequency Aging Using int. Reference − − − ±1.0 ppm/year Measurement Speed (for power meas.) @ Low Noise Mode 1 - 6000 − 100 − msec @ Faster Mode − 30 − Sample time (for frequency meas.) 8 − 100 1000 3000 msec Input Impedance − − 50 − Ω Reference In Frequency − − 10 − MHz Reference In Impedance − − 50 − Ω Reference In Power − -5 − +10 dBm Supply Voltage via USB port 1 - 6000 4.5 5 5.5 V Current (via USB port, in USB control) 1 - 6000 − 370 500 mA Current (via USB port, in Ethernet control) 1 - 6000 − 380 500 mA Ethernet communication Supports both Telnet and HTTP protocols over TCP/IP with dynamic(DHCP) or static IP Electrical Specifications (CW) 1, -30 dBm to +20 dBm, 1 to 6000 MHz 1 All specifications apply to continuous wave (CW) signals. 2 Maximum continuous safe operational power limit: +23 dBm. Performance is guaranteed up to +20 dBm. 3 The FCPM-6000RC can operate down to -32 dBm, however performance is guaranteed only in the range specified in the table. 4 Minimum power for Frequency measurement at 190-240 MHz may degrade by up to 3 dB due to measurement band switching. 5 When using Faster mode at high frequencies below -20dBm, use of averaging is recommended to prevent noise errors. 6 When using Faster mode power reading below -20dBm, uncertainty value may increase by up to 0.2 dB relative to Low noise mode power reading. 7 Accuracy shown using external 10 MHz reference synchronized to test signal. Using Internal Reference adds 2 ppm of tested frequency to the accuracy values shown. 8 Software function set by user, default option 1000 mec.
FCPM-6000RCIntegrated Frequency Counter & Power Meter Absolute Maximum Ratings Parameter Ratings Operating Temperature 0°C to 50°C Storage Temperature -30°C to 70°C VUSB Max. 6 V DC Voltage @ RF port 15 V RF Power(CW) @ RF port +25 dBm DC Voltage @ Reference Input 25 V RF Power(CW) @ Reference Input +13 dBm Parameter Requirements Interface USB HID or HTTP Get/Post or Telnet protocols Host operating system - USB control Windows 32/64 Bit operating system: Windows 98 ®, Windows XP ®, Windows Vista ®, Windows 7®, Windows 8® Windows 10® Linux ® support: 32/64 Bit operating system Host operating system - Ethernet control Any Windows®, Mac®, or Linux® computer with a network port and Ethernet-TCP/IP (HTTP or Telnet protocols) support Hardware Pentium ® II or better , RAM 256 MB Y control cable for USB and Ethernet (supplied) Model to be used with the supplied control cable only Minimum System Requirements Permanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability. Reference Input (BNC-Female) Signal Input (N-Typ-Male) Power & Control (Push-Pull connector) Connections
FCPM-6000RCIntegrated Frequency Counter & Power Meter Typical Performance Curves 1.00 1.03 1.06 1.09 1.12 1.15 0 1000 2000 3000 4000 5000 6000 VSWR (:1) Frequency (MHz) VSWR 0°C +25°C +50°C -4% -2% 0 1000 2000 3000 4000 5000 6000 Linearity (%) Frequency (MHz) Linearity @ +25OC -30 to 0 dBm 0 to +20 dBm -0.4 -0.3 -0.2 -0.1 0.0 0.1 0.2 0 1000 2000 3000 4000 5000 6000 UUncertainty (dB) Frequency (MHz) Uncertainty of Power Measurement @ +25°C -30 dBm -10 dBm 0 dBm +5 dBm +10 dBm +15 dBm +20 dBm -42 -39 -36 -33 -30 -27 0 1000 2000 3000 4000 5000 6000 Power In (dBm) Frequency (MHz) Typ. Input Power Threshhold for Frequency Measurement @ +25°C -500 -300 -100 100 300 500 0 1000 2000 3000 4000 5000 6000 Uncertainty (Hz) Frequency (MHz) Uncertainty of Frequency Measurement @ +25°C -30 dBm -20 dBm -10 dBm 0 dBm +5 dBm +15 dBm +20 dBm
FCPM-6000RCIntegrated Frequency Counter & Power Meter Outline Drawing (JL2029) 9 FCPM-6000RC to be used with the supplied control cable only. A B C D E F G H J K L WT. GRAMS Outline Dimensions ( )inch mm Note 9 Indicates Grey per Pantone 427C P/N: B16-10-174+ REV: ORx1 Indicates Cutout
FCPM-6000RCIntegrated Frequency Counter & Power Meter Connection diagrams Connection diagram for USB control USB-RJ45-CBL-7+ Connect to D.U.T. Push-Pull connector RJ45 connector - Not in use for USB control USB Type A plug - Connect to computer USB socket Reference input (connect to external reference if needed) Note: Commercially available PoE splitter not supplied by Mini-Circuits Connection diagram for Ethernet control, using PoE system RJ45 connector - for LAN data USB-RJ45-CBL-7+ Connect to D.U.T. Push-Pull connector PoE Splitter USB Type A plug - for +5V power only RJ45 connector - Connected to PoE/LAN port Reference input (connect to external reference if needed) Connection diagram for Ethernet control, using power adapter USB Type A plug - Connect to USB-AC/DC-5 power adaptor RJ45 connector - Connected to LAN network port USB-RJ45-CBL-7+ Connect to D.U.T. Push-Pull connector USB-AC/DC-5 Reference input (connect to external reference if needed)
FCPM-6000RCIntegrated Frequency Counter & Power Meter Model Description FCPM-6000RC Integrated Frequency Counter & Power Meter
Ordering Information
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Calibration Description CAL-FCPM-6000RC Calibration Service Click Here Included Accessories Part No. Description USB-AC/DC-5 AC/DC Power Adapter with US, EU, IL, UK, AUS, and China two pin power plugs 10, 11. Operating temperature: 0°C to +45°C, AC Input: 100-240V, 47-63 Hz, DC Output 5±0.25 V , IMax=1A FCPM-CD Software CD USB-RJ45-CBL-7+12 6.6 ft (2 m) “Y” data cable with USB Type-A and RJ45 plug connectors US Europe & IL UK Australia & China 10 Power plugs for other countries are also available, if you need a power plug for a country not listed in the table please contact 11 The USB-AC/DC-5 may be used to provide the 5VDC power input via USB port if operating with Ethernet control. Not required if using USB control. 12 FCPM-6000RC to be used with the supplied control cable only. Optional Accessories Description USB-AC/DC-5 (spare) AC/DC 5VDC Power Adapter with US, EU, IL, UK, AUS, and China power plugs USB-RJ45-CBL-7+ (spare) 6.6 ft (2 m) “Y” data cable with USB Type-A and RJ45 plug connectors NF-SM50+ N-Type Female to SMA Male Adapter (For mating with SMA devices).