FCP400-12G BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
© 2015 Bel Power Solutions, Inc. North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support@psbel.com BCD.00141_AC RoHS lead free solder Certified to efficiency 80plus platinum Wide input voltage range 90-264 VAC Two outputs (one high current output) Low conducted and radiated EMI (EN 55022 class B) Safety approved to the latest editions of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 High density design 4” x 1.58” x 8.5” cassette Highly-efficient topology I2C interface Overtemperature, output overvoltage, and output overcurrent protection Supervisory signaling Included ORing FET for true redundant operation The FCP400-12G is highly-efficient AC-DC power supply, with one high current output and an additional standby output, which can be used in a wide range of applications. Active current share along with internal ORing FET allow the FCP400's to be also used in redundant, h ot-swap applications. Model meet international safety standards and display the CE Mark for the low Voltage Directive. Telecommunication Equipment NOT RECOMMENDED FOR NEW DESIGN
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00141_AC Model Input Voltage VAC Output 1 Output 2 Rated Power W Vo nom VDC Io max ADC Vo nom VDC Io max ADC FCP400-12G* 90-264 12 33.3 12 0.7 408 * Suffix “G” added to the part number means the product is RoHS compliant for all 6 substances Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the converter. PARAMETER CONDITIONS / DESCRIPTION MIN MAX UNITS Input Voltage Continuous Transient, 60 ms 264 300 VAC VAC Operating Temperature Ambient Vi min-Vi max, Io nom, cooling by internal fan 0 55 °C Storage Temperature Non-operational -40 85 °C All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage 90 115/230 264 VAC Turn-On Input Voltage Ramping up 70 - 90 VAC Turn-Off Input Voltage Ramping down 70 - 90 VAC Input Frequency 47 50/60 63 Hz Inrush Current Limitation 115/230 VAC 20/27 A Power Factor Vi nom, Io nom 0.96 Efficiency Vi = 230 VAC, Io nom 90 % All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Output Voltage Setpoint Accuracy Vi = 230 VAC, Io1 @ 16.6 ADC, TC = 25 °C -0.01 0.01 VDC Output Current V1 Output Current V2 0 33.3 0.7 33.3
0.7 ADC
Static Line Regulation V1 Vi min-Vi max, Vi nom, 0-100% Io nom -0.06 0.06 VDC Static Load Regulation V1 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io nom -0.1 0.1 VDC Hold-Up Time Starting at Vi = 230 VAC, Po nom 20 ms Dynamic Load Regulation Load change 5A to 16A, 16A to 27A and back voltage deviation recovery time -0.24 0.24 400 VDC Start-Up Time Vi nom, Io nom 1.5 s Output Voltage Ripple and Noise Vi nom, Io nom, 20 MHz bandwidth 120 mVpp NOT RECOMMENDED FOR NEW DESIGN
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00141_AC All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Fuse Not user accessible 8A T Input Transient Protection With varistor Output No-load and short circuit proof short circuit proof overload (latch style) 110 130 % Io nom Overvoltage Protection Latch type – disable output V1 115 130 % Vo nom Overtemperature Protection Automatic power shutdown at TA = 62 °C All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION I2C Digital Bus Reports information and monitors alarm functions PS Seated Signal Contact closure to GND PS Remote Shutdown TTL compatible signal, open collector. Power supply enabled at Low or TTL "0" (e.g. by connecting of pin 22 to 0V or GND) AC Fail Warning (I2C & OC)* Supervisory AC input voltage; DC fail (I2C & OC)* Supervisory under- and overvoltage pre-ORing FET of V1 Temperature Warning (I2C & OC)* Indicates if unit is operating normally or in overtemperature, Pre-warning time >10 ms Fan Fail (I2C & OC)* Indicates if fan speed is below 80% of the currently required level Current Share Active current share for V1 Droop load characteristic for V2 Status Indication LEDs: DC OK (green), AC OK (green) * Signal provided by I2C interface or by open collector (OC) All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Operating Humidity Relative humidity, non-condensing 10 90 % Storage Humidity Relative humidity, non-condensing 5 95 % Shock IEC/EN 60068-2-27, 11 ms 30 gn Sinusoidal Vibration IEC/EN 60068-2-6 2-8 Hz 8-200 Hz 200-500 Hz mil gn gn MTBF MIL-HDBK-217F Notice 2, GB, 25 °C 300 kh The electric strength test is performed in the factory as routine test in accordance with EN50514, IEC/EN 60950, and UL 1950 and should not be repeated in the field. Bel Power Solutions will not honor any warranty claims resulting from electric strength field tests. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Insulation Safety Rating Input/Case Input/Output Output/Case Basic Reinforced Functional Electric Strength Test Voltage Input/Case Input/Output Output/Case 1.5 3.0 0.5 kVAC kVAC kVDC NOT RECOMMENDED FOR NEW DESIGN
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00141_AC All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER DESCRIPTION CRITERION Electrostatic Discharge IEC/EN 61000-4-2, level 4 (contact/air) 8/15 kV, Criterion B Electromagnetic Field IEC/EN 61000-4-3, level 3 10 V/m, Criterion A Electr. Fast Transients / Burst IEC/EN 61000-4-4, level 3 (direct/capacitive) 2/1 kV, Criterion B Surge IEC/EN 61000-4-5, level 3 (L/L, L/C) 1/2 kV, Criterion B Voltage Dips and Interruptions IEC/EN 61000-4-11 <20 ms Criterion A >20 ms Criterion B RF Conducted Immunity IEC/EN 61000-4-6 10 VAC, AM 80%, 1 kHz, Criterion A Emissions Radiated/Conducted CISPR 22/EN 55022/EN 61204 Class A / Class B Harmonics IEC/EN 61000-3-2 Class B Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Pass All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION Fan speed control 18 fan speed levels depending on inlet temperature, AC voltage and load. Fan speed and temperature information available on I2C digital bus. µC supply voltage in-/output (Pin 10) If unit is operating: 5 to 11V is provided at pin 3. If unit is NOT operating, pin 3 is input from a parallel connected unit for µC supply. Figure 1 - Efficiency vs. Output Load PARAMETER CONDITIONS / DESCRIPTION Weight 2.866 lb (1.3 kg) 0 5 10 15 20 25 30 35 EFFICIENCY VS. OUTPUT LOAD Vi = 115Vac Vi = 230Vac NOT RECOMMENDED FOR NEW DESIGN
© 2015 Bel Power Solutions, Inc. +1.866.513.2839 tech.support@psbel.com BCD.00141_AC Figure 6 – Molex Connector (39-00-0046) OUTPUT CONNECTOR DESCRIPTION PIN LOCATION REFERENCE NAME
12 V Output 4,5,6,16,17,18 Vo1
12 V Output RTN 1,2,3,13,14,15 Vo1 RTN
AC-fail, DC-fail, Temp.-fail 9 PS_FAIL Power Supply Present Signal 23 PS_PRSNT_L Serial Data Line 11 SDA Serial Clock Line 12 SCL Address Input Line A0 21 AO Address Input Line A1 20 A1 5 to 11 V 10 µC supply voltage bus FAN OK 24 FAN_FAIL PS Remote Shut Down 22 PS_RSD_H
12 V Standby RTN 7 Vo2 RTN / Logic Ground / 5 to 11 V RTN
12 V Standby 19 Vo2
Active Current share 8 ACS NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. NOT RECOMMENDED FOR NEW DESIGN