6870675 TURCK | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Features
■Flow sensor for liquid media ■Calorimetric principle ■Adjustment via potentiometer ■LED band ■Operating range 4…30 l/min ■DC 3-wire, 19.2…28.8 VDC ■NO contact, PNP output ■Connector device, M12 × 1 Wiring diagram Functional principle The function of the inline flow sensors is based on the thermo-dynamic principle. Heat is generated in a measuring tube and absorbed by the flowing medium. The transported heat loss is thus a measure of the flow speed. Thus TURCK's wear-free flow sensors reliably monitor the flow of gaseous and liquid media. A low pressure drop and fast response to flow rate variations are the outstanding features of these devices.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|2 FCI-N3/4D20A4P-AP8X-H1141 | 11/07/2023 23-28 | technical changes reserved Technical data Electrical connection Connector, M12 × 1 Process Pressure 20 bar Process connection 3/4'' NPT Switching state LED chain, Green/yellow/red Flow state display LED chain Indication: Drop below setpoint LED Red Indication: Setpoint reached LED Yellow Indication: Setpoint exceeded 4 × LEDs Green