A Division of Powers Holdings, Inc. www.curtisind.com Specifications subject to change. Dimensions are shown for reference purposes only. MEDICAL FILTERS

72 General Purpose Filtered Modules

MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Frequency - MHz F3099AA06 F3099BB06 QC/QC ø Common Differential F3099 RFI Filters Features:

  • Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment, both patient care and onpatient categories.
  • Leakage current in this series is extremely low to satisfy the stringest leakage current limit imposed by safety regulations for medical and dental equipment. Specifications: Maximum Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 250VAC Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1450VDC Insulation Resistance: 9 x 10 9 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: Quick Connect B: Wire Maximum Leakage Current: Each Line to Ground F3000 Series 115VAC, 60Hz: 2 μA 250VAC, 50Hz: 5 μA Agency Approvals:F3099 Series Simplified Schematic NOTE: Other combinations of terminals may be specified on special order. LOAD L N LINE L G N Amps A B C D E 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 2.53 (64,30) 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 1.32 (33,5) F3099AA (6Amp) Dimensions AD B EC 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) AD B C WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. BLUE BLUE BROWN G/Y BROWN E