F2FL MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
MODEL: F2FL F2FL SPECIFICATIONS ES-5445 Rev.6 Page 1/2 http://www.m-system.co.jp/ Super-mini Signal Conditioners F2 Series SQUARE ROOT EXTRACTOR (non-isolated) Functions & Features
- Provides a DC output proportional to the root of input signal
- Low-end cutout Typical Applications
- Converting differential pressure to flow 22.5 (.89) (2.95) mm (inch) 107 (4.21) MODEL: F2FL–[1]6–R[2]
ORDERING INFORMATION
- Code number: F2FL-[1]6-R[2] Specify a code from below for each of [1] and [2]. (e.g. F2FL-66-R/Q)
- Specify the specification for option code /Q (e.g. /C01) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) B: 2 – 10 mA DC (Input resistance 500 Ω) C: 1 – 5 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) Voltage 6: 1 – 5 V DC (Input resistance 100 kΩ min.) OUTPUT Voltage 6: 1 – 5 V DC (Load resistance 10 kΩ min.) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating GENERAL SPECIFICATIONS Construction: Stand-alone; terminal access at the front Connection: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm) Housing material: Flame-resistant resin (black) Isolation: Input or output to power Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Low-end cutout: Approx. 4 – 8 % (output) INPUT 8% or less 4% or more
0 OUTPUT
■ DC Current: Input resistor incorporated INSTALLATION Current consumption
- DC: Approx. 80 mA Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 150 g (0.33 lb) PERFORMANCE in percentage of span Accuracy: ±0.2 % (input 1 – 100 %) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 90 %) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input or output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive
MODEL: F2FL F2FL SPECIFICATIONS ES-5445 Rev.6 Page 2/2 http://www.m-system.co.jp/ EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 Approval: UL/C-UL general safety requirements (UL 3111-1, CAN/CSA-C22.2 No.1010-1) EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 1 2 3 4 5 6 7 8 DIN RAIL 35mm wide 22.5 (.89) 75 (2.95)
- When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SZ 1 Sq. Root Extractor Low-end Cutout OUTPUT *Input shunt resistor incorporated for current input. INPUT POWER Specifications are subject to change without notice.