F2D MSYSTEM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

MODEL: F2D F2D SPECIFICATIONS ES-5422 Rev.6 Page 1/3 http://www.m-system.co.jp/ Super-mini Signal Conditioners F2 Series CURRENT LOOP SUPPLY (non-isolated) Functions & Features

  • Powers a 4 – 20 mA DC current loop
  • Electrically isolating output signal from power input
  • Shortcircuit protection
  • Applicable to smart transmitters Typical Applications
  • Various 2-wire transmitters 22.5 (.89) (2.95) mm (inch) 107 (4.21) MODEL: F2D–24–R[1]

ORDERING INFORMATION

  • Code number: F2D-24-R[1] Specify a code from below for [1]. (e.g. F2D-24-R/Q)
  • Specify the specification for option code /Q (e.g. /C01) SUPPLY OUTPUT 24: 24 V DC INPUT Current 4 – 20 mA DC (Input resistance 250 Ω) OUTPUT 1 Voltage 1 – 5 V DC (Load resistance 250 kΩ min.) OUTPUT 2 Current 4 – 20 mA DC POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [1] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating GENERAL SPECIFICATIONS Construction: Stand-alone; terminal access at the front Connection: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm) Housing material: Flame-resistant resin (black) Isolation: Input or output to power SUPPLY OUTPUT Output voltage: 24 – 28 V DC with no load Current rating: ≤ 22 mA DC
  • Shortcircuit Protection Current limited: 35 mA max. Protected time duration: No limit INPUT SPECIFICATIONS ■ DC Current: Input resistor incorporated INSTALLATION Current consumption
  • DC: Approx. 80 mA Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: DIN rail Weight: 150 g (0.33 lb) PERFORMANCE in percentage of span Accuracy: ±0.1 % (accuracy of the receiving resistor) Temp. coefficient: ±0.003 %/°C (±0.002 %/°F) (temp. coefficient of the receiving resistor) Line voltage effect to supply output: ±3 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input or output to power to ground)

MODEL: F2D F2D SPECIFICATIONS ES-5422 Rev.6 Page 2/3 http://www.m-system.co.jp/ STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581 Approval: UL/C-UL general safety requirements (UL 3111-1, CAN/CSA-C22.2 No.1010-1) EXTERNAL DIMENSIONS unit: mm (inch) 1 2 3 4 5 6 7 8 DIN RAIL 35mm wide 22.5 (.89) 75 (2.95)

  • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) 1 2 3 4 5 6 7 8 (.24) Jumper

MODEL: F2D F2D SPECIFICATIONS ES-5422 Rev.6 Page 3/3 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Current Limiter OUTPUT 1 OUTPUT 2 – 2 2-WIRE TRANSMITTER * Short across these terminals using the attached jumper (or leadwire) for large voltage allowance at Output 2. Be sure to match specifications of smart transmitter. Do not connect a capacitive load to Output 1. ** Be sure to short across these terminals using the attached jumper (or leadwire) when not using Output 2. 250Ω POWER Specifications are subject to change without notice.