61F-GP-N2 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 7

Technical content

Conductive Level Controller 61F-GP-N2 Automatic Water Supply and Drainage Control

  • Ideal for level control of any conductive liquid.
  • Compact plug-in controller for single- or two-point control of conductive liquid level.
  • 24/110/120/220/230/240 VAC operation possible.
  • Easy installation on DIN rail.
  • Low voltage (AC) electrodes.
  • Full surge protection.

220 VAC

Ordering Information

When placing your order, be sure to specify the desired operating voltage. ■Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Electrode Holders Electrode Separators Compact plug-in conductive level controller 61F-GP-N2 Example: 61F-GP-N2 120 VAC Rated supply voltage Applications For city water and other general-use elec- trodes. Easy-to-replace separate versions facili- tate maintenance of electrodes. When mounting space is limited. Special 3-pole holder of small size and light weight. Ideal for soft drink vendors, etc., where only limited space is avail- able. For low specific liquids. Used for sewage, sea water, etc., having a low specific resis- tance. In sewage use, electrode holders must be installed 10 to 20 cm apart from one another. For acids, alkalis and sea wa- ter, electrode holders may be as much as 1 meter apart to operate properly. When resistance to high pressure is required. Ide- al for use in tanks where temperature or pressure inside the tank is high, e.g. 250°C Mounting style Flange Screw Flange Screw Insulator material Phenol resin Phenol resin Ceramics Fluorine Resin Max. temperature 70°C (without water drips or vapour on the surface of the electrode holder) 150°C (without water drips or vapour on the surface of the electrode holder) 250°C (without water drips or vapour on the surface of the electrode holder) No. of elec- trodes No. of electrodes Model

1 F03-14-1P

3 F03-14-3P

Selection Guide for Electrodes, Connecting and Lock Nuts Application Example

  • Level control in tanks, reservoirs, sewage plants, underground wells, mixing plants etc.
  • Level control for element protec tion in pipes, channels, and irriga- tion systems.
  • Flow detection in pipes, channels, and irrigation systems.
  • Ice bank control in cold drink dispensers, ice makers, water chillers, bulk milk tanks, etc.
  • Dispensing of liquids by volume.
  • Indication of liquid buildup due to filter blockages.
  • Pollution/foul water detection for rivers, drains, etc.
  • Alarm control warning of abnorma l or dangerously high or low lev- els. Specifications *Secondary voltage of transformer Applicable liquids Material Models for individual electrode assembly components Electrode (1m long) Connecting nut Lock nut Model Indication mark Model Inscription Model Inscription Purified city water, industrial water, sewage SUS-304 (AISI-304) F03-01-SUS304 1 line F03-02-SUS304 --- F03-03-SUS304 --- Purified city water, industrial water, sewage, dilute alka- line solution SUS316 (AISI-316) F03-01-SUS316 2 lines F03-02-SUS316 6 F03-03-SUS316 6 Supply voltage 24, 110, 120, 220, 230, 240 VAC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage Interelectrode voltage* 8 VAC Power consumption Approx. 3.2 VA Operate resistance Approx. 4 KΩ min. Between electrode E1 and E3 Release resistance Approx. 15 KΩ max. Between electrode E2 and E3 Response time Operate: 80 ms max., Release: 160 ms max. Control output 10 A, 250 VAC (at 40°C)

3 A, 250 VAC (at 55°C)

Insulation resistance 100 MΩ max. (at 500 VDC) between power terminals and electrode terminals, and between electrode terminals and contact terminals Dielectric strength 2,000 VAC, 50/60 Hz for 1 min., between power terminals and electrode terminals, and between elec- trode terminals and contact terminals Ambient temperature Operating: –10°C to 55°C Ambient humidity Operating: 45% to 85% Life expectancy Mechanical: 10,000,000 operations min. Weight Approx. 190 g Approved standards UL508, CSA C22.2 No.14, EN61010-1, EN61326-1 Industrial electromagnetic environment

Automatic Water Supply and Drainage Control 1. Water supply  Connect electromagnetic switch coil terminal A to Tb.  The pump stops when the water level reaches E1 and starts when the water level drops below E2. 2. Drainage  Connect the electromagnetic switch coil terminal A to Ta.  The pump starts when the water level reaches E1 and stops when the water level drops below E2. Note: 1. The diagram shows the connections for water supply. When draining, change the connection Tb to Ta. 2. The earth terminal must be grounded. Operation The conductive type level controller consists of a plug-in controller connected to a set of stainless steel probes. These are cut to length and inserted vertically into the liquid. A low voltage is applied between these probes and the earth probe (or tank, if it is electrically conductive). The water provides a current between the earth probe and the high-level probe. The output relay in the controller is ener- gized when the water level reaches the high-level probe and de-ener- gized when the water level falls below it. For two-point control a low-level pr obe is used as well. In this case the relay does not de-energize until the water level falls below the low-level probe. Using the low-level probe allows a wide differential between switching a pump on and off, and can avoid excessive pump operation during tank emptying or f illing. If this differential is not required, the low-level probe need not be connected. Dimensions Note: All units are in millimeters unless otherwise indicated. 7E1 Ta Tb Tc Power source 220 or

240 VAC

A M P 61F- GP-N2 PF083A 49.4

■Electrode Holders PS-3S PS-31 BF-1 BS-1(S) 40 20 13 8026 E3 E2 E2E3 34 dia. PF2 parallel thread (effective dia.: 58.135)9-dia. rubber bushing (inner) PF2 65 dia. hole Used with coupling Used with mounting bracket PS-3S/-3SR PS-4S/-4SR PS-5S/-5SR Mounting Holes Screw Holes Dust preventive rubber cap (optional) 11-dia. PF1/2 27.5-dia. * Standard holder construction includes three integral 300 mm length electrodes. However, a type having 1,000 mm length electrodes is available on request. Mounting Holes Rubber packing 7 12 38.5 PF1/2 Parallel thread Electrode SUS304 (49) 20-dia. 2317 14 48 33 -dia. Terminal bolt SUS201 (M6) Nut (M6) Cast iron Two M5 x 25 mounting screws 26-dia. hole Two, 6-dia. holes Terminal bolt SUS304 (M4) P=0.7 Width across flats: 20 Two M4 P=0.7 Nut (iron) M18 P=1.5 (fine screw thread) M18 P=1.5 50 51 101 24-dia. M18 P=1.5 50 51 101 Terminal bolt SUS304 (M4) P=0.7 Width across flats: 20 Two, M4 P=0.7 24 dia. M18 P=1.5 (fine screw thread) BS-1 BS-1S BS-1S-1 BS-1S2

■Electrode Separators F03-14 1P (for Single Pole) F03-14 3P (for Three Poles) Precautions ■How to Mount Electrodes Connecting Electrodes to Electrode Holders Connecting One Electrode to Another ■Application When using electrodes in sea water or sewage, provide a sufficient interval (normally 1 m) between t he electrodes. If the sufficient inter- val cannot be provided, employ a low-sensitivity type Floatless Level Controller. When taping one of the electrodes to prevent it from contacting the other electrodes in water, do not tape the electrode entirely but leave at least 100 mm of its end uncovered. When the required length of the electrode is more than 1 m, use a separator at each joint of two electrodes so as to prevent the elec- trodes from contacting one another. (NOTE: Avoid use of the separa- tors in dust-containing liquids.) Usually, electrodes are used in a se t of three: long, medium, and short. Connect the short electrode to E1, the medium electrode to E2, and the long electrode to E3. Make E3 at least 50 mm longer than E2. Electrodes are in actual contact with the liquid. Standard electrodes are made of stainless steel and usable in purified water, sea water, sewage, acid (except acetic acid, su lfuric acid, etc.) and alkaline liq- uids, although they may corrode depending upon the temperature and working conditions. Note that the Conductive Level Controller 61F-GP-N2 is capable of controlling liquids with specif ic resistances of up to 30 k Ω-cm when the controller employs a type PS-3S electrode holder with the elec- trode(s) submerged to a depth of 30 mm max. 6.5-dia. 28-dia. 41-dia. Three 7-dia. Electrode holder Clamp screw Connecting nut 1. Spin a lock nut and a spring washer onto the electrode. 2. Fully fit the electrode into the connecting nut attached to the electrode holder. 3. Tighten the electrode with the two clamp screws. Spring washer Lock nut Electrode 4. Secure the connecting nut by tightening the lock nut and spring washer. Electrode Connecting nut 1. Spin a lock nut and a spring washer onto the electrode. 3. Tighten the electrode with the two clamp screws. Spring washer Lock nut 4. Secure the connecting nut by tightening the lock nut and spring washer. Spring washer 2. Fully fit the electrode into the connecting nut attached to the electrode holder. 50 mm min. 1 m1 m Kind of water Specific resistance Applicable type City water 5 to 10 kΩ-cm General-purpose type Well water 2 to 5 kΩ-cm General-purpose type Industrial water 5 to 15 kΩ-cm General-purpose type Rainwater 15 to 25 kΩ-cm General-purpose type Sea water 0.03 kΩ-cm Low-sensitivity type Sewage 0.5 to 2 kΩ-cm Low-sensitivity type Distilled water 100 kΩ-cm or less High-sensitivity type Over 100 kΩ-cm Consult OMRON

■Safety Precautions !WARNING !CAUTION Precautions for Safe Use 1. Precautions for the environment  Use and preserve within the proper temperature and humidity described in the specifications.  Temperature of surroundings for preservation (including during transportation) and use: −10 to 55°C, humidity: 45 to 85%.  Do not install, among others, near heat devices such as coils or other devices having coils, etc.  Avoid preserving (including duri ng transportation) and using in a humid place, in a corrosive gas environment, outdoors and in a place which receives direct sunlight.  Preserve and use without exposing to danger of explosion, flamma- ble dust, gas and vapor, excessive dust, and saline spray or drop- lets.  Avoid preserving (including duri ng transportation) and using in a place which is vulnerable to flooding or oil spillage.  Avoid preserving (including duri ng transportation) and using in a place where vibrations and impacts are strong. Similarly, avoid using next to a high-capacity contactor which may impacts at oper- ation. Doing so causes malfunctions such as chattering, etc.  Do not install the product near devices generating strong high-fre- quency waves or surges. When usi ng a noise filter, check the volt- age and current and install it as close to the product as possible. 2. Cautions for Use  Read the instruction manual and catalog before operating and maintaining the product.  Fit socket(s) and DIN rail(s) so that the screws are tight. If the screws are not tight, DIN rail(s), socket(s), the product and cable(s) may lead to come off.  Be sure to fit socket(s) to DIN rail(s) without fail.  Use metal strengthener(s) to main tain a firm connection between the product and socket(s).  Read the instructions manual and catalog before the operation and maintenance of the product.  When fitting crimping terminal(s) to terminal screw(s), use a tight- ening torque of between 0.45 and 0.6 N·m  Use power supply of appropriate spec ifications to provide control source(s), inputs, etc., and to wire cables. [Recommended cable to wire between the model 61F and elec- trode(s) when using three-core cabtire cable(s) of completely insu- lated 600 V 0.75 mm VCT: 50 m max.]  Do not put power line(s), high-volt age cable(s) and wire(s) of elec- trode circuit(s) in the same duct nor wire closely. Doing so causes malfunctions by getting vulnerable to induction noise.  Shorten the distance for wiring between the model 61F and elec- trode holders as much as possib le. Long distance for wiring may causes malfunctions because stray capacitance may influence operation, or abnormal surges or noise may run through electrode circuit(s).  Be sure to ground common electr ode terminal(s). Doing so can reduce some effects of noise.  Use the product within the noted supply voltage and rated load.  Before using, recheck the application, wiring, power supply, etc.  Check the application and power supply. Power supply (AC 220 V, AC 230 V) consists of other specifications. If the power voltage is not AC 200 V or AC 100 V, follow the instruc- tions described on the device.  Firmly ground the earth terminal No.4.  Make sure that electrode probes in the liquid do not come in con- tact one another as it may cause malfunction. Use separator when connecting.  Tighten nuts for electrode probe(s) firmly.  Prevent flotage from attaching to electrode.  This device is not available when the resistance is too high and is not conductive such as oil. Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Make sure that the terminal cover is installed before using the product. Do not attempt to disassemble, repair, or modify the product. Doing so may occasionally result in minor or moderate injury due to electric shock. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.