DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 16
Technical content
Warning: Some customers may want Linx radio frequency (“RF”) products to control machinery or devices remotely, including machinery or devices that can cause death, bodily injuries, and/or property damage if improperly or inadvertently triggered, particularly in industrial settings or other applications implicating life-safety concerns (“Life and Property Safety Situations”). NO OEM LINX REMOTE CONTROL OR FUNCTION MODULE SHOULD EVER BE USED IN LIFE AND PROPERTY SAFETY SITUATIONS. No OEM Linx Remote Control or Function Module should be modified for Life and Property Safety Situations. Such modification cannot provide sufficient safety and will void the product’s regulatory certification and warranty. Customers may use our (non-Function) Modules, Antenna and Connectors as part of other systems in Life Safety Situations, but only with necessary and industry appropriate redundancies and in compliance with applicable safety standards, including without limitation, ANSI and NFPA standards. It is solely the responsibility of any Linx customer who uses one or more of these products to incorporate appropriate redundancies and safety standards for the Life and Property Safety Situation application. Do not use this or any Linx product to trigger an action directly from the data line or RSSI lines without a protocol or encoder/ decoder to validate the data. Without validation, any signal from another unrelated transmitter in the environment received by the module could inadvertently trigger the action. All RF products are susceptible to RF interference that can prevent communication. RF products without frequency agility or hopping implemented are more subject to interference. This module does have a frequency hopping protocol built in, but the developer should still be aware of the risk of interference. Do not use any Linx product over the limits in this data guide. Excessive voltage or extended operation at the maximum voltage could cause product failure. Exceeding the reflow temperature profile could cause product failure which is not immediately evident. Do not make any physical or electrical modifications to any Linx product. This will void the warranty and regulatory and UL certifications and may cause product failure which is not immediately evident.
1 Description
2 Ordering Information
3 Absolute Maximum Ratings
4 Electrical Specifications
5 Pad Layout
6 Pin Assignments
6 Pin Descriptions
8 Schematic
9 Power Supply Requirements
10 Dimensions
– –
Description
The HumPRCTM Series is the most complete system to integrate bi-directional remote control into many different applications. No programming is required and both module and finished hardware options are available, making it the easiest solution to implement. The module provides long-range transmission at 868MHz and 900MHz for multi-region operation, utilizing frequency hopping and industry-standard encryption for secure and robust communications. The HumPRCTM Series interoperates with Linx’s HumPROTM family, making it the only remote control solution that simultaneously supports data applications for seamless integration with sensor and control IoT applications. The evaluation module contains the surface mount HumPRCTM Series transceiver module on a board with through-hole headers. This small board simplifies prototyping with the HumPRCTM Series module, allowing it to be integrated into a host PCB without requiring any soldering. There are three versions of the evaluation module, populated with the three versions of the HumPRCTM Series module. The standard version has the standard module and an MMCX connector for use with the Master Development System. The “-CAS” version has an edge-mount SMA (868MHz) or RP-SMA (900MHz) connector for the antenna . The “-UFL” version uses the module’s on-board U.FL connector for the antenna. HumPRC TM Series Evaluation Module Data Guide Revised 10/15/2018 Figure 1: HumPRCTM Series Evaluation Modules; from left: EVM-*-PRC, EVM-*-PRC-CAS, EVM-***-PRC-UFL
– –
Ordering Information
Figure 2: Ordering Information 868MHz HumPRC™ Series Carrier Board, Not Certified, Through-Hole Pin Interface, MMCX Connector for the Development System EVM-900-PRC 900MHz HumPRC™ Series Carrier Board, Not Certified, Through-Hole Pin Interface, MMCX Connector for the Development System EVM-868-PRC-CAS 868MHz HumPRC™ Series Carrier Board, Through-Hole Pin Interface, SMA Connector EVM-868-PRC-UFL 868MHz HumPRC™ Series Carrier Board, Through-Hole Pin Interface, U.FL / MHF Compatible Connector EVM-900-PRC-CAS 900MHz HumPRC™ Series Carrier Board, Through-Hole Pin Interface, RP-SMA Connector, FCC & IC Certified EVM-900-PRC-UFL 900MHz HumPRC™ Series Carrier Board, Through-Hole Pin Interface, U.FL / MHF Compatible Connector, FCC & IC Certified HUM-868-PRC 868MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, External Antenna Connection HUM-900-PRC 900MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, External Antenna Connection HUM-868-PRC-CAS 868MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, External Antenna Connection HUM-868-PRC-UFL 868MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, U.FL / MHF Compatible Connector HUM-900-PRC-CAS 900MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, External Antenna Connection, FCC & IC Certified HUM-900-PRC-UFL 900MHz HumPRC™ Series Remote Control Transceiver, Castellation Interface, U.FL / MHF Compatible Connector, FCC & IC Certified MDEV-868-PRC 868MHz HumPRC™ Series Master Development System MDEV-900-PRC 900MHz HumPRC™ Series Master Development System MDEV-PGDOCK Development System Programming Dock MDEV-PROTO Development System Prototype Board CON-SOC-EVM EVM Module Socket Kit
– – Absolute Maximum Ratings Figure 3: Absolute Maximum Ratings Absolute Maximum Ratings Supply Voltage Vcc −0.3 to +3.9 VDC Any Input or Output Pin −0.3 to VCC + 0.3 VDC RF Input 0 dBm Operating Temperature −40 to +85 ºC Storage Temperature −40 to +85 ºC Exceeding any of the limits of this section may lead to permanent damage to the device. Furthermore, extended operation at these maximum ratings may reduce the life of this device. Warning: This product incorporates numerous static-sensitive components. Always wear an ESD wrist strap and observe proper ESD handling procedures when working with this device. Failure to observe this precaution may result in module damage or failure.
– – Electrical Specifications Figure 4: Electrical Specifications Please see the HumPRCTM Series Transceiver module data guide for full electrical specifications. HumPRCTM Series Transceiver Specifications Parameter Symbol Min. Typ. Max. Units Notes Power Supply Operating Voltage VCC 2.0 3.6 VDC TX Supply Current lCCTX at +10dBm 40.5 41.5 mA 1,2 at 0dBm 22 24 mA 1,2 RX Supply Current lCCRX 23.5 24.5 mA 1,2,3 Power-Down Current lPDN 0.7 1.4 µA 1,2 RF Section Operating Frequency Band FC MHz EVM-900-PRC 902 928 MHz EVM-868-PRC 863 870 MHz RF Data Rate EVM-900-PRC 19.2 152.34 kbps EVM-868-PRC 38.4 kbps Serial Data Rate 9.6 115.2 kbps Receiver Sensitivity 5 EVM-900-PRC @min rate –98 –101 dBm 5 EVM-900-PRC @max rate –91 –94 dBm 5 EVM-868-PRC –97 –100 dBm 5 Output Power PO EVM-900-PRC +8.5 +9.5 dBm 6 EVM-868-PRC +8.5 +10.6 dBm 6 Antenna Port RF Impedance RIN 50 Ω 4 Environmental Operating Temp. Range −40 +85 ºC 4 1. Measured at 3.3V VCC 2. Measured at 25ºC 3. Input power < -60dBm 4. Characterized but not tested 5. PER = 5% 6. Into a 50-ohm load
– –
7 MODE_IND
9 CMD_DATA_IN
11 LATCH_EN
13 ACK_EN
15 CMD_DATA_OUT
17 VCC
POWER_DOWN 10 NC 12 PAIR 14 LNA_EN 16 NC 18 PA_EN 20 NC 22 NC 24 NC 26 NC 28 NC 30 NC 32 NC 34 NC 36 41 S3 42 S4 43 S5 44 S6 45 S7
46 ACK_OUT
38 S0ANTENNA 1 2-5 GND (RF Connector)
Figure 7: EVM-fff-PRC Pin Assignments Pin Descriptions Pin Assignments Pin Descriptions Pin Number Name I/O Description
1 ANTENNA — 50-ohm RF Antenna Port
2, 3, 4, 5, 6 GND — Ground
7 MODE_IND O
Mode Indicator. This line indicates module activity. It can source enough current to drive a small LED, causing it to flash. The duration of the flashes indicates the module’s current state. 8 RESET2 I This line resets the module when pulled low. It should be pulled high for normal operation.
9 CMD_DATA_IN I
Command Data In. Input line for the serial interface commands. If serial control is not used, this line should be tied to supply to minimize current consumption.
10 POWER_DOWN I
Power Down. Pulling this line low places the module into a low-power state. The module is not functional in this state. Pull high for normal operation. Do not leave floating.
11 LATCH_EN I
If this line is high, then the status line outputs are latched (a received command to activate a status line toggles the output state). If low, then the output lines are momentary (active for as long as a valid signal is received).
– – Pin Descriptions Pin Number Name I/O Description 12, 18, 22–37, 47-56 NC — No Electrical Connection. Do not connect any traces to these lines.
13 ACK_EN I
Pull this line high to enable the module to send an acknowledgement message after a valid control message has been received.
14 PAIR1 I
A high on this line initiates the Pair process, which causes two units to accept each other’s transmissions. It is also used with a special sequence to reset the module to factory default configuration. 15 CMD_DATA_OUT O Command Data Out. Output line for data and serial commands
16 LNA_EN O
Low Noise Amplifier Enable. This line is driven high when receiving. It is intended to activate an optional external LNA.
17 VCC — Supply Voltage
19 C0 I
This line sets the input/output direction for status lines S0-S3. When low, the lines are outputs; when high they are inputs.
20 PA_EN O
Power Amplifier Enable. This line is driven high when transmitting. It is intended to activate an optional external power amplifier.
21 C1 I
This line sets the input/output direction for status lines S4-S7. When low, the lines are outputs; when high they are inputs. 38–45 S0–S71 I/O Status Lines. Each line can be configured as either an input to register button or contact closures or as an output to control application circuitry.
46 ACK_OUT O
This line goes high when the module receives an acknowledgement message from another module after sending a control message. 1. These lines have an internal 20kΩ pull-down resistor 2. These lines have an internal 10kΩ pull-up resistor Figure 8: EVM-fff-PRC Pin Descriptions
– – Power Supply Requirements The module does not have an internal voltage regulator, therefore it requires a clean, well-regulated power source. The power supply noise should be less than 20mV. Power supply noise can significantly affect the module’s performance, so providing a clean power supply for the module should be a high priority during design. A 10Ω resistor in series with the supply followed by a 10μF tantalum capacitor from Vcc to ground helps in cases where the quality of supply power is poor. This filter should be placed close to the module’s supply lines. These values may need to be adjusted depending on the noise present on the supply line. 10Ω 10µF Vcc IN Vcc TO MODULE Figure 10: Supply Filter
– – 29.72 mm (1.170 in) 26.64 mm (0.970 in) 5.98 mm (0.235 in) 37.43 mm (1.473 in) 6.53 mm (0.257 in) 9.83 mm (0.387 in) Ø6.35 mm (0.25 in) Ø7.93 mm (0.312 in) 4.24 mm (0.167 in) 11.51 mm (0.453 in) 7.54 mm (0.297 in) Figure 13: EVM-fff-PRC-CAS Dimensions
Linx Technologies is continually striving to improve the quality and function of its products. For this reason, we reserve the right to make changes to our products without notice. The information contained in this Data Guide is believed to be accurate as of the time of publication. Specifications are based on representative lot samples. Values may vary from lot-to-lot and are not guaranteed. “Typical” parameters can and do vary over lots and application. Linx Technologies makes no guarantee, warranty, or representation regarding the suitability of any product for use in any specific application. It is the customer’s responsibility to verify the suitability of the part for the intended application. NO LINX PRODUCT IS INTENDED FOR USE IN ANY APPLICATION WHERE THE SAFETY OF LIFE OR PROPERTY IS AT RISK. Linx Technologies DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL LINX TECHNOLOGIES BE LIABLE FOR ANY OF CUSTOMER’S INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING IN ANY WAY FROM ANY DEFECTIVE OR NON-CONFORMING PRODUCTS OR FOR ANY OTHER BREACH OF CONTRACT BY LINX TECHNOLOGIES. The limitations on Linx Technologies’ liability are applicable to any and all claims or theories of recovery asserted by Customer, including, without limitation, breach of contract, breach of warranty, strict liability, or negligence. Customer assumes all liability (including, without limitation, liability for injury to person or property, economic loss, or business interruption) for all claims, including claims from third parties, arising from the use of the Products. The Customer will indemnify, defend, protect, and hold harmless Linx Technologies and its officers, employees, subsidiaries, affiliates, distributors, and representatives from and against all claims, damages, actions, suits, proceedings, demands, assessments, adjustments, costs, and expenses incurred by Linx Technologies as a result of or arising from any Products sold by Linx Technologies to Customer. Under no conditions will Linx Technologies be responsible for losses arising from the use or failure of the device in any application, other than the repair, replacement, or refund limited to the original product purchase price. Devices described in this publication may contain proprietary, patented, or copyrighted techniques, components, or materials. Under no circumstances shall any user be conveyed any license or right to the use or ownership of such items. ©2018 Linx Technologies. All rights reserved. The stylized Linx logo, Wireless Made Simple, WiSE, CipherLinx and the stylized CL logo are trademarks of Linx Technologies. Linx Technologies
159 Ort Lane