Features

 50 to 1218 MHz frequency range  Flat gain  Very low distortion  Excellent input/output match  Low DC power consumption  Single 12 V supply  Surface-mount package compatible with automatic assembly  Repeatability of monolithic fabrication  RoHS-compliant packaging  Highly reliable GaAs MESFET technology Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04–0074.

Description

The ACA1212 is a highly linear, high output power integrated RF amplifier designed for CATV head ends and HFC distribution systems. The IC consists of two parallel amplifiers cascaded between transmission line baluns that are optimized for exceptionally low distortion, high output power, and high crash point in a thermally enhanced surface-mount package. The ACA1212 covers the full 50 to 1218 MHz CATV downstream band demanded by DOCSIS 3.1 systems. A block diagram of the ACA1212 is shown in Figure 1. The device package and pinout are shown in Figure 2. Signal pin assignments and functional pin descriptions are described in Table 1. RF Input RF Output12 dB 12 dB 204202-001 Figure 1. ACA1212 Block Diagram

Figure 2. ACA1212 Pinout Table 1. AWB7124 Signal Pin Descriptions1

1 GND Ground 9 GND Ground

2 N/C No connection 10 N/C No connection

3 RFINA Input to Amplifier A 11 RFOUTB Output from Amplifier B

4 GND Ground 12 GND Ground

5 GND Ground 13 GND Ground

6 RFINB Input to Amplifier B 14 RFOUTA Output from Amplifier A

7 IADJ Current adjust 15 N/C No connection

8 GND Ground 16 GND Ground

1 The center ground pad must have a low inductance and low thermal resistance connection to the application’s printed circuit board ground plane.

Table 2. Recommended operating conditions are specified in Table 3, and electrical specifications are provided in Table 4. Table 2. ACA1212 Absolute Maximum Ratings1 or below their nominal value. Exceedi ng any of the limits listed here may result in permanent damage to the device. 2 Pins 3 and 6 should be AC-coupled. No external DC bias should be applied. ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD handling precautions should be used at all times. Table 3. ACA1212 Recommended Operating Conditions1 1 Performance is guaranteed only under the conditions listed in this table. Table 4. ACA1212 Electrical Specifications1 1 Measured with a balun on input and output of the device. See Figure 3 for test setup. 2 Device measured with 79 analog channels, +47 dBmV output power at 1000 MHz with a 3 dB tilt and QAM to 1000 MHz.

Evaluation Board components. Figure 3. ACA1212 Evaluation Board Schematic Table 6. ACA1212 Evaluation Board Bill of Materials (BOM)

Figure 4. ACA1212 PCB Layout Footprint Dimensions

Figure 5. ACA1212 Package Dimensions

Figure 6. ACA1212 Tape and Reel Dimensions

DATA SHEET • ACA1212: 1.2 GHz CATV LINE AMPLIFIER MMIC Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 204202C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 13, 2017 9

Ordering Information

Model Number Package Description Component Packaging ACA1212P2 16-pin wide body SOIC with heat slug 1500-piece tape and reel EVB1212 Evaluation Board part number Copyright © 2017 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.