EUS25-096 MURATA-PS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

T echnical enquiries email: sales@murata-ps.com , tel: +508 339 3000

1 EUS25-096 6200911514_B01 18/04/08

Features: 9 48 Vin, Isolated, 5:1 Fixed Conversion Ratio 9 240 Watt Output at 48 Vin, 55 C, 200 LFM 9 175 Watt Output at 38 Vin, 55 C, 200 LFM

9 Industry Standard 1/8 Brick Footprint

9 Remote Enable (Primary Side, Positive or Negative)

9 Over-temperature and Over Current Protection

9 Direct Parallel Operation for Higher Power

9 RoHS Compliant

Input Characteristics Notes & Conditions Min Typ. Max Units Input Voltage Operating Range 36 48 55 Vdc Input Voltage Absolute Maximum 60 Vdc Turn-on Threshold 34 36 Vdc Turn-off Threshold 32 35 Vdc Input Undervoltage Lockout Hysteresis Voltage 2 Vdc Turn-on Threshold 55 58 Vdc Turn-off Threshold 56 59 Vdc Input Overvoltage Lockout Hysteresis Voltage 2 Vdc Maximum Input Current Steady-State (26 A out) 6.4 Adc No-Load Input Current Enabled state, no load (48 Vin) 50 mA Disabled Input Current Disabled state (48 Vin) 6 mA Input Reflected Ripple Current Note (9) 50 mA p-p Inrush Current Transient 0.2 A s Enable – Negative Logic Version Internal 10 K pull-up to 5 V. On State range Off State range -0.1 2.4 0.8 5.0 Vdc Vdc Enable – Positive Logic Version Internal 100 K pull-down to GND. On State range Off State range 2.4 -0.1 5.0 0.8 Vdc Vdc Table 2 Output Characteristics Notes & Conditions Min Typ. Max Units Output Load Regulation Io = 0 to 25 A 0.5 V Output Voltage Total Regulation Vin = 38 to 55 V, Io = 0 to 25 A, 6.60 11.20 Vdc Vin = 42 to 53 V, Io = 0 to 25 A, 7.80 10.7 Vdc Output Ripple Voltage & Noise 20 MHz Bandwidth 90 150 mV p-p Output Current Operating Range 0 25 A Output Current Share Accuracy Percent deviation from ideal (8) < 10 % Efficiency Vin = 48 V, Io = 25 A 95 % Turn-On Time Vin present: Enable to 90% Vout 10 mS Start-up Inhibit Time Enabled: Vin applied to 90% Vout 120 mS Transient Response 25% step, 0.1A/μs, ΔVo 160 mV Recovery Time 100 μs Maximum Output Capacitance 3000 μF

2 EUS25-096 6200911514_B01_18/04/08

Protection Characteristics Notes & Conditions Min Typ. Max Units Output Over-Current Shutdown Non-Latching 27 30 33 A Re-start rate 60 msec Over Temperature Shutdown Non-Latching 125 130 °C Over Temperature Restart Hysteresis 10 °C Table 4 General Specifications Notes & Conditions Min Typ. Max Units Isolation Voltage Input to Output 2250 Vdc Isolation Resistance Input to Output 10 Mohm Storage Temperature Range Non-condensing -40 125 °C Operating Temperature Range Ambient -40 100 °C Thermal Measurement Location Temperature See mechanical drawing for TML location 120 °C Material Flammability UL 94V-0 MTBF Calculated (Bellcore TR-332) 2.7 x10 Hrs Demonstrated > 2 x10 Hrs Dimension 2.28”L x 0.9”W x 0.48”H (max) (57.9L x 22.9W x 12.19H mm max) Weight 30 grams Table 5 Standards Compliance Notes & Conditions (6) UL/CSA 60950 Basic Insulation EN60950 Certified by TUV Notes: (1) Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted. (2) Output Ripple Voltage and noise is specif ied when measured with a 10uF tantalum and a 1uF ceramic capacitor at the converter output pins. (3) Transient response is specified without a capacitor at the output of the converter. (4) Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location. (5) See ‘Safety Considerations’ shown in Figure 1. (6) De-rating curves are conducted in a cont rolled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified. (7) Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse). (8) Current share accuracy is optimized when the sour ce and load impedance presented to each converter is equal. (9) Input Reflected Ripple is specified when measured with a 12uH source inductance. Without an input filter inductor, input ripple is less than 1 Arms for an input filter capacitance rated 70 mohms esr

3 EUS25-096 6200911514_B01_18/04/08

Pin # Pin Name Function Notes & Conditions

1 Vi(+) Positive Input Voltage

2 En Input Enable / Disable

Referenced to Vi(-). Positive Logic: Floating = Enabled Negative Logic: Floating = Disabled

3 Vi(-) Negative Input Voltage

4 Vo(-) Negative Output Voltage

5 Vo(+) Positive Output Voltage

4 EUS25-096 6200911514_B01_18/04/08

Output Voltage vs. Current Figure 3 EUS25 Efficiency (%) vs Iout (A) 02468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 Iout [Adc] Efficiency [%] Vin=36V Vin=48V Vin=55V EUS25-096 Output vs. Current 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 02468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 Iout [Adc] Vout [V] Vin=36V Vin=48V Vin=55V

5 EUS25-096 6200911514_B01_18/04/08

Power Derating Curves, TTML=120C Output Power as a function of Ambient Temperature and Input Voltage EUS25-096_Pout(W) vs. Tamb(C) and Airflow 38Vin, 120C, Parallel Airflow (IN to Out) 100 120 140 160 180 200 40 45 50 55 60 65 70 75 80 85 90

400 LFM

300 LFM

200 LFM

100 LFM

EUS25-096_Pout(W) vs. Tamb(C) and Airflow 42Vin, 120C, Parallel Airflow (IN to Out) 100 120 140 160 180 200 220 40 45 50 55 60 65 70 75 80 85 90 EUS25-096_Pout(W) vs. Tamb(C) and Airflow 48Vin, 120C, Parallel Airflow (IN to Out) 100 120 140 160 180 200 220 240 40 45 50 55 60 65 70 75 80 85 90 EUS25-096_Pout(W) vs. Tamb(C) and Airflow 55Vin, 120C, Parallel Airflow (IN to Out) 100 120 140 160 180 200 220 240 260 280 40 45 50 55 60 65 70 75 80 85 90 EUS25-096_Pout(W) vs. Tamb(C) and Vin (V).

200 LFM, 120C, Parallel Airflow (IN to Out)

40 45 50 55 60 65 70 75 80 85 90 Vin = 55V Vin = 48V Vin = 42V Vin = 38V

6 EUS25-096 6200911514_B01_18/04/08

Turn-on from Vin (Enable On) Turn-on from Enable (Vin present) ---TBD-- ----TBD--- Figure 9 Ch1: Vin; Ch2: V out Figure 10 Ch2: Vout; Ch4: Enable Vin=48V, Io=22A, Co=3000uF Vin=48V, Io=22A, Co=3000uF Output Ripple/Noise Thermal Image ---TBD--- Figure 11 Vout @ 50 mV/div. Vin=48V, Io=25A, Co = 0 Figure 12 Vi=42 V, Iout=25 A, @ 25 C, 200 LFM 32.2°C 105.2°C SP01: 78.7 SP02: 8 0.8 SP03 : 85.0 SP04: 79.3 AIRFLOW

7 EUS25-096 6200911514_B01_18/04/08

Ordering Information

The EUS series of converters are certified to the standards listed in the ‘Standards Compliance’ section in the table above. If this product is built into information technology equipment, the installation must comply with the above standard. An external input fuse (10 A recommended), must be used to meet the above requirements. The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV- 2 requirements. The converters and materials meet UL 94V-0 flammability ratings. RoHS Compliant The EUS series of converters is in compliance with the European Union Directive 2002/95/EC (RoHS) with repsect to the following sustances: lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).