T echnical enquiries email: sales@murata-ps.com , tel: +508 339 3000 Features: 9 48 Vin, Isolated, 4:1 Fixed Conversion Ratio 9 220 Watt Nominal Output (at 48 Vin, 55 C, 200 LFM) 9 170 Watt Output (at 38 Vin, 55 C, 200 LFM)

9 Industry Standard 1/8 Brick Footprint

9 Remote Enable (Primary Side, Positive or Negative)

9 Over-temperature and Over Current Protection

9 Direct Parallel Operation for Higher Power Applications

9 RoHS Compliant

Input Characteristics Notes & Conditions (1) Min Typ. Max Units Input Voltage Operating Range 36 48 55 Vdc Input Voltage Absolute Maximum 60 Vdc Turn-on Threshold 36 37.5 Vdc Turn-off Threshold 34 35.5 Vdc Input Undervoltage Lockout Hysteresis Voltage 2 Vdc Turn-on Threshold 56 58 Vdc Turn-off Threshold 55 57 Vdc Input Overvoltage Lockout Hysteresis Voltage 2 Vdc Maximum Input Current Steady-State (23 A out) 5.5 Adc No-Load Input Current Enabled state, on load (48 Vin) 80 mA Disabled Input Current Disabled state (48 Vin) 6 mA Input Reflected Ripple Current 50 mA p-p Inrush Current Transient 0.2 A s Enable – Negative Logic Version Internal 10 K pull-up to 5 V. On State range Off State range -0.1 2.4 0.8 5.0 Vdc Vdc Enable – Positive Logic Version Internal 100 K pull-down to GND. On State range Off State range 2.4 -0.1 5.0 0.8 Vdc Vdc Table 2 Output Characteristics Notes & Conditions (1) Min Typ. Max Units Output Load Regulation Io = 0 to 15 A 0.7 V Output Voltage Total Regulation Vin = 36 to 55 V, Io = 0 to 15 A, 8.3 13.75 Vdc Vin = 42 to 53 V, Io = 0 to 15 A, 9.7 13.25 Vdc Output Ripple Voltage & Noise 20 MHz Bandwidth 90 150 mV p-p Output Current Operating Range 0 15 A Efficiency Vin = 48 V, Io = 15 A 96 % Turn-On Time Vin present: Enable to 90% Vout 10 mS Start-up Inhibit Time Enabled: Vin applied to 90% Vout 80 mS Transient Response (3) 25% step, 0.1A/μs, ΔVo 160 mV Recovery Time 100 μs Maximum Output Capacitance (4) 3000 μF BUS CONVERTER EUS15-120 Model

Protection Characteristics Notes & Conditions (1) Min Typ. Max Units Output Over-Current Shutdown Non-Latching 21 23 25 A Re-start rate TBD msec Short Circuit Current Peak TBD Ap Over Temperature Shutdown (5) Non-Latching 125 130 °C Over Temperature Restart Hysteresis 10 °C Table 2 General Specifications Notes & Conditions (1) Min Typ. Max Units Isolation Voltage Input to Output 2250 Vdc Isolation Resistance Input to Output 10 Mohm Storage Temperature Range Non-condensing -40 125 °C Operating Temperature Range Ambient (7) -40 100 °C Thermal Measurement Location Temperature (7) See mechanical drawing for location 120 °C Material Flammability UL 94V-0 MTBF Calculated (Bellcore TR-332) 1 TBD x10 Hrs Demonstrated TBD x10 Hrs Dimension 2.28”L x 0.9”W x 0.48”H (max) (57.9L x 22.9W x 12.19H mm max) Weight grams Table 3 Standards Compliance Notes & Conditions (6) UL/CSA 60950 Basic Insulation EN60950 Certified by TUV Notes: (1) Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted. (2) Output ripple voltage and noise is specified when measured with no external capacitance. (3) Transient response is specified without a capacitor at the output of the converter. (4) Product operates with an external capac itance greater than specified. For higher values please contact a Celestica representative. (5) Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location. (6) See ‘Safety Considerations’ shown on last page. (7) De-rating curves are conducted in a cont rolled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified. (8) Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow). BUS CONVERTER EUS15-120 Model

Pin # Pin Name Function Notes & Conditions

1 Vi(+) Positive Input Voltage

2 En Input Enable / Disable

Referenced to Vi(-). Positive Logic: Floating = Enabled Negative Logic: Floating = Disabled

3 Vi(-) Negative Input Voltage

4 Vo(-) Negative Output Voltage

5 Vo(+) Positive Output Voltage

Output Voltage vs. Current Figure 3 Vo (V) vs. Io (A) and Vin (V) 0 2 4 6 8 1 01 21 41 61 82 0

55 Vin

48 Vin

42 Vin

38 Vin

Efficiency (% ) vs. Iout (A) and Vin (V) 88% 89% 90% 91% 92% 93% 94% 95% 96% 97% 0 2 4 6 8 1 01 21 41 61 82 0 55Vin 48Vin 42Vin 38Vin BUS CONVERTER EUS15-120 Model

Thermal Derating Curves (Transverse) TTML=120C Airflow from pin 3 to pin 1 Figure 7 Iout (A) vs. Tamb (C) and Air Flow (LFM)

100 LFM

200 LFM

300 LFM

400 LFM

Iout (A) vs. Tamb (C) and Air Flow (LFM) 25 35 45 55 65 75 85100 LFM Iout (A) vs. Tamb (C) and Air Flow (LFM) Iout (A) vs. Tamb (C) and Air Flow (LFM)

Pout (W) vs. Tamb (C) and Vin (V)

Ordering Information

The EUS series of converters are certified to the standards listed in the ‘Standards Compliance’ section in the table above. If this product is built into information technology equipment, the installation must comply with the above standard. An external input fuse (10 A recommended), must be used to meet the above requirements. The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements. The converters and materials meet UL 94V-0 flammability ratings. BUS CONVERTER EUS15-120 Model