Features
- Surface Mount
- 1:4 Impedance Ratio
- CT on Secondary
- Available on Tape & Reel
Description
M/A-COM’s ETC4-1-2 is a 1:4 RF flux coupled step-up transformer in a low cost, surface mount package. Ideally suited for high volume cellular and wireless applications. Typical applications include single to balanced mode conversion and impedance matching. E-Series RF 1:4 Flux Coupled Step-up Transformer 2.0 - 800 MHz ETC4-1-2 Schematic Note: Mean and Sigma calculated from average loss at @ 105 MHz. Please Note that the photograph above indicates typical package only, not actual unit. 0$? 0$? Electrical Specifications @25°C Parameter Units Nominal Maximum Mean (x) Sigma (σ) Frequency Range 2.0 - 800 MHz — — — — Insertion Loss (fL - fU) 10 - 100 MHz 5.0 - 600 MHz dB dB 1.0 2.0 1.21 0.032 Amplitude Unbalance 10 - 100 MHz 2.0 - 800 MHz dB dB 0.25 1.0 Phase Unbalance 10 - 500 MHz 2.0 - 800 MHz Degrees Degrees 2.0 Primary Dot 4 Primary 5 3 turns
3 Secondary Dot
1 Secondary
2 Secondary CT
V2.00 S 0258 M Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. Absolute Maximum Ratings Parameter Absolute Maximum RF Power 250 mW DC Current 30 mA Operating Temperature -40°C to +85°C Storage Temperature -40°C to +85°C Functional Configuration Function Pin No. Secondary 1 Secondary CT 2 Secondary Dot 3 Primary Dot 4 Primary 5 Insertion Loss Typical Performance Over Extended Bandwidth (30kHz - 1.0GHz) Phase Unbalance Input Impedance Amplitude Unbalance Note: All measurements performed on Hewlett Packard 8753D Network Analyzer (201 sample points, linear scale) in a 50 ohm coplanar waveguide environment. Tables created using MDS software. ETC4-1-2