DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 19
Technical content
1© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 One world. One KEMET Benefits
- Long life, up to 12,000 hours
- Ope rating temperature of up to +105°C
- Saf ety vent on the capacitor base Overview KEMET’s ESU Series of aluminum electrolytic single-ended capacitors are designed for long life (up to 12,000 hours) applications.
Applications
Typical applications include electronic lighting and power. Single-Ended Aluminum Electrolytic Capacitors ESU Series, +105ºC Part Number System ESU 336 M 160 A H8 AA Series Capacitance Code (pF) Tolerance Rated Voltage (VDC) Electrical Parameters Size Code Packaging Single-Ended Aluminum Electrolytic First two digits represent significant figures for capacitance values. Last digit specifies the number of zeros to be added. M = ±20% 160 = 160 200 = 200 250 = 250 350 = 350 400 = 400 450 = 450 A = Standard See Dimension Table See Ordering Options Table
2© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Ordering Options Table Diameter Packaging Type Lead Type Lead Length (mm) Lead and Packaging Code Standard Bulk Packaging Options 4 – 22 Bulk (bag) Straight 20/15 Minimum AA Standard Auto-Insertion Packaging Options 4 – 5 Tape & Reel Formed to 2.5 mm H 0 = 16±0.75 LA 6.3 Tape & Reel 2.5 mm Lead Spacing H0 = 18.5±0.75 KA 8 Tape & Reel Formed to 5 mm H 0 = 16±0.75 JA 10 – 13 Ammo 5 mm Lead Spacing H 0 = 18.5±0.75 EA 16 – 18 Ammo 7.5 mm Lead Spacing H0 = 18.5±0.75 EA Other Packaging Options 4 – 8 Ammo Formed to 5 mm H 0 = 16±0.75 DA 4 – 8 Ammo Straight H0 = 18.5±0.75 EA 4 – 5 Ammo Formed to 2.5 mm H0 = 16±0.75 FA 4 – 6.3 Tape & Reel Formed to 5 mm H 0 = 16±0.75 JA 4 – 5, 8 – 18 Tape & Reel Straight H0 = 18.5±0.75 KA Contact KEMET for other Lead and Packaging options Environmental Compliance As an environmentally conscious company, KEMET is working continuously with improvements concerning the environmental effects of both our capacitors and their production. In Europe (RoHS Directive) and in some other geographical areas like China, legislation has been put in place to prevent the use of some hazardous materials, such as lead (Pb), in electronic equipment. All products in this catalog are produced to help our customers’ obligations to guarantee their products and fulfill these legislative requirements. The only material of concern in our products has been lead (Pb), which has been removed from all designs to fulfill the requirement of containing less than 0.1% of lead in any homogeneous material. KEMET will closely follow any changes in legislation world wide and makes any necessary changes in its products, whenever needed. Some customer segments such as medical, military and automotive electronics may still require the use of lead in electrode coatings. To clarify the situation and distinguish products from each other, a special symbol is used on the packaging labels for RoHS compatible capacitors. Because of customer requirements, there may appear additional markings such as LF = Lead Free or LFW = Lead Free Wires on the label.
3© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Dimensions – Millimeters L P SIDE VIEW TERMINAL END VIEW LL− LL+ D d Size Code D L p d LL+/LL- Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance H8 10 ±0.5 16 +2.0/−0 5 ±0.5 0.6 Nominal 20/15 Minimum H4 10 ±0.5 20 +2.0/−0 5 ±0.5 0.6 Nominal 20/15 Minimum L3 13 ±0.5 20 +2.0/−0 5 ±0.5 0.6 Nominal 20/15 Minimum L4 13 ±0.5 25 +2.0/−0 5 ±0.5 0.6 Nominal 20/15 Minimum
4© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Performance Characteristics Item Performance Characteristics Capacitance Range 6.3 – 330 µF Capacitance Tolerance ±20% at 120 Hz/20°C Rated Voltage 160 – 450 VDC Life Test 8,000 – 10,000 hours (see conditions in Test Methods & Performance) Operating Temperature −25°C to +105°C Leakage Current I ≤ 0.04 CV +100 µA C = rated capacitance (µF), V = rated voltage (VDC). Voltage applied for 2 minutes at 20°C. Impedance Z Characteristics at 120 Hz Rated Voltage (VDC) 160 200 250 350 400 450 Compensation Factor of Ripple Current (RC) vs. Frequency Rated Voltage (VDC) 120 Hz 1 kHz 10 kHz 100 kHz Coefficient 0.50 0.80 0.90 1.00 Test Method & Performance Conditions Load Life Test Shelf Life Test Temperature 105°C 105°C Test Duration Can Ø = 10.0 mm 10,000 hours 1,000 hours Can Ø ≥ 12.5 mm 12,000 hours Ripple Current Maximum ripple current specified at 100 kHz 105°C No ripple current applied Voltage The sum of DC voltage and the peak AC voltage must not exceed the rated voltage of the capacitor No voltage applied Performance The following specifications will be satisfied when the capacitor is restored to 20°C: Capacitance Change Within ±20% of the initial value Dissipation Factor Does not exceed 200% of the specified value Leakage Current Does not exceed specified value
5© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Shelf Life The capacitance, ESR and impedance of a capacitor will not change significantly after extended storage periods, however the leakage current will very slowly increase. KEMET's E-series aluminum electrolytic capacitors should not be stored in high temperatures or where there is a high level of humidity. The suitable storage condition for KEMET's E-series aluminum electrolytic capacitors is +5 to +35ºC and less than 75% in relative humidity. KEMET's E-series aluminum electrolytic capacitors should not be stored in damp conditions such as water, saltwater spray or oil spray. KEMET's E-series aluminum electrolytic capacitors should not be stored in an environment full of hazardous gas (hydrogen sulphide , sulphurous acid gas, nitrous acid, chlorine gas, ammonium, etc.) KEMET's E-series aluminum electrolytic capacitors should not be stored under exposure to ozone, ultraviolet rays or radiation. If a capacitor has been stored for more than 18 months under these conditions and it shows increased leakage current, then a treatment by voltage application is recommended. Re-age (Reforming) Procedure Apply the rated voltage to the capacitor at room temperature for a period of one hour, or until the leakage current has fallen to a steady value below the specified limit. During re-aging a maximum charging current of twice the specified leakage current or 5 mA (whichever is greater) is suggested.
6© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Table 1 – Ratings & Part Number Reference (1) Insert packaging code. See Ordering Options Table for available options. VDC Rated Capacitance
120 Hz 20°C
(µF) Case Size D x L (mm) DF (tan δ %) RC 100 kHz 105°C (mA) LC 20ºC
2 Minutes
(µA) Part Number 160 33 10 x 16 15 500 311.2 ESU336M160AH8(1) 160 47 10 x 20 15 580 400.8 ESU476M160AH4(1) 160 68 13 x 20 15 720 535.2 ESU686M160AL3(1) 160 100 13 x 25 15 970 740.0 ESU107M160AL4(1) 160 150 16 x 25 15 1120 1060.0 ESU157M160AM7(1) 160 220 16 x 32 15 1300 1508.0 ESU227M160AM2(1) 160 330 18 x 36 15 1380 2212.0 ESU337M160AN2(1) 160 560 18 x 50 15 2086 3684.0 ESU567M160AN9(1) 200 22 10 x 16 15 500 276.0 ESU226M200AH8(1) 200 33 10 x 20 15 520 364.0 ESU336M200AH4(1) 200 47 13 x 20 15 660 476.0 ESU476M200AL3(1) 200 68 13 x 25 15 720 644.0 ESU686M200AL4(1) 200 100 16 x 25 15 1120 900.0 ESU107M200AM7(1) 200 150 16 x 32 15 1620 1300.0 ESU157M200AM2(1) 200 220 18 x 32 15 2080 1860.0 ESU227M200AN1(1) 200 390 18 x 50 15 3380 3220.0 ESU397M200AN9(1) 250 10 10 x 16 15 320 200.0 ESU106M250AH8(1) 250 22 10 x 20 15 500 320.0 ESU226M250AH4(1) 250 33 13 x 20 15 800 430.0 ESU336M250AL3(1) 250 47 13 x 20 15 980 570.0 ESU476M250AL3(1) 250 100 16 x 25 15 1530 1100.0 ESU107M250AM7(1) 250 150 18 x 25 15 1940 1600.0 ESU157M250AN5(1) 250 220 18 x 36 15 2753 2300.0 ESU227M250AN2(1) 250 330 18 x 50 15 3912 3400.0 ESU337M250AN9(1) 350 6.8 10 x 16 20 280 195.2 ESU685M350AH8(1) 350 10 10 x 20 20 350 240.0 ESU106M350AH4(1) 350 22 13 x 20 20 650 408.0 ESU226M350AL3(1) 350 33 13 x 25 20 900 562.0 ESU336M350AL4(1) 350 47 16 x 25 20 1000 758.0 ESU476M350AM7(1) 350 68 16 x 32 20 1100 1052.0 ESU686M350AM2(1) 400 6.8 10 x 16 20 140 208.8 ESU685M400AH8(1) 400 10 10 x 20 20 180 260.0 ESU106M400AH4(1) 400 22 13 x 20 20 430 452.0 ESU226M400AL3(1) 400 33 16 x 25 20 520 628.0 ESU336M400AM7(1) 400 47 16 x 20 20 852 520 ESU476M400AM5(1) 400 47 16 x 32 20 700 852.0 ESU476M400AM2(1) 400 68 18 x 32 20 870 1188.0 ESU686M400AN1(1) 400 100 18 x 50 20 1290 1700.0 ESU107M400AN9(1) 450 10 10 x 20 20 180 280.0 ESU106M450AH4(1) 450 15 13 x 20 20 380 370.0 ESU156M450AL3(1) 450 22 13 x 25 20 500 496.0 ESU226M450AL4(1) 450 33 16 x 25 20 560 694.0 ESU336M450AM7(1) 450 47 16 x 36 20 880 946.0 ESU476M450AM3(1) 450 68 16 x 36 20 1110 1324.0 ESU686M450AM3(1) 450 100 18 x 50 20 1560 1900.0 ESU107M450AN9(1) VDC Rated Capacitance Case Size DF RC LC Part Number
7© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Mounting Positions (Safety Vent) In operation, electrolytic capacitors will always conduct a leakage current which causes electrolysis. The oxygen produced by electrolysis will regenerate the dielectric layer but, at the same time, the hydrogen released may cause the internal pressure of the capacitor to increase. The overpressure vent (safety vent) ensures that the gas can escape when the pressure reaches a certain value. All mounting positions must allow the safety vent to work properly. Installing
- A general principle is that lower-use temperatures result in a longer, useful life of the capacitor. For this reason, it should be ensured that electrolytic capacitors are placed away from heat-emitting components. Adequate space should be allowed between components for cooling air to circulate, particularly when high ripple current loads are applied. In any case, the maximum category temperature must not be exceeded.
- Do not deform the case of capacitors or use capacitors with a deformed case.
- Verify that the connections of the capacitors are able to insert on the board without excessive mechanical force.
- If the capacitors require mounting through additional means, the recommended mounting accessories shall be used.
- Verify the correct polarization of the capacitor on the board.
- Verify that the space around the pressure relief device is according to the following guideline: Case Diameter Space Around Safety Vent ≤ 16 mm > 2 mm > 16 to ≤ 40 mm > 3 mm > 40 mm > 5 mm It is recommended that capacitors always be mounted with the safety device uppermost or in the upper part of the capacitor.
- If the capacitors are stored for a long time, the leakage current must be verifi ed. If the leakage current is superior to the value listed in this catalog, the capacitors must be reformed. In this case, they can be reformed by application of the rated voltage through a series resistor approximately 1 kΩ for capacitors with V R ≤ 160 V (5 W resistor) and 10 kΩ for the other rated voltages.
- In the case of capacitors connected in series, a suitable voltage sharing must be used. In the case of balancing resistors, the approximate resistance value can be calculated as: R = 60/C KEMET recommends, nevertheless, to ensure that the voltage across each capacitor does not exceed its rated voltage.
8© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Application and Operation Guidelines Electrical Ratings: Capacitance (ESC) Simplifi ed equivalent circuit diagram of an electrolytic capacitor The capacitive component of the equivalent series circuit (Equivalent Series Capacitance ESC) is determined by applying an alternate voltage of ≤ 0.5 V at a frequency of 120 or 100 Hz and 20°C (IEC 384-1, 384-4). Temperature Dependence of the Capacitance Capacitance of an electrolytic capacitor depends upon temperature: with decreasing temperature the viscosity of the electrolyte increases, thereby reducing its conductivity. Capacitance will decrease if temperature decreases. Furthermore, temperature drifts cause armature dilatation and, therefore, capacitance changes (up to 20% depending on the series considered, from 0 to 80°C). This phenomenon is more evident for electrolytic capacitors than for other types. Frequency Dependence of the Capacitance Effective capacitance value is derived from the impedance curve, as long as impedance is still in the range where the capacitance component is dominant. C = 1 C = Capacitance (F) 2π fZ f = Frequency (Hz) Z = Impedance (Ω) Capacitance Change (%) Capacitance Change vs. Temperature (typical value) Temperature (°C) Capacitance Change (%) Capacitance Change vs. Frequency (typical value) Frequency (kHz)
9© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Dissipation Factor tan δ (DF) Dissipation Factor tan δ is the ratio between the active and reactive power for a sinusoidal waveform voltage. It can be thought of as a measurement of the gap between an actual and ideal capacitor. reactive active ideal actual δ Tan δ is measured with the same set-up used for the series capacitance ESC. tan δ = ω x ESC x ESR where: ESC = Equivalent Series Capacitance ESR = Equivalent Series Resistance Dissipation Factor (%) Dissipation Factor vs. Frequency (typical value) Frequency (kHz) Dissipation Factor (%) Dissipation Factor vs. Temperature (typical value) Temperature (°C)
10© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Equivalent Series Inductance (ESL) Equivalent Series Inductance or Self Inductance results from the terminal confi guration and internal design of the capacitor. Equivalent Series Capacitance (ESC) Equivalent Series Resistance (ESR) Equivalent Series Inductance (ESL) Capacitor Equivalent Internal Circuit Equivalent Series Resistance (ESR) Equivalent Series Resistance is the resistive component of the equivalent series circuit. ESR value depends on frequency and temperature and is related to the tan δ by the following equation: ESR = Equivalent Series Resistance (Ω) ESR = tan δ tan δ = Dissipation Factor 2πf ESC ESC = Equivalent Series Capacitance (F) f = Frequency (Hz) Tolerance limits of the rated capacitance must be taken into account when calculating this value. ESR (Ω) ESR Change vs. Frequency (typical value) Frequency (kHz) ESR (Ω) ESR Change vs. Temperature (typical value) Temperature (°C)
11© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Impedance (Z) Impedance of an electrolytic capacitor results from a circuit formed by the following individual equivalent series components: Equivalent Capacitance C o R e L C e Co Re L Ce Co = Aluminum oxide capacitance (surface and thickness of the dielectric) Re = Resistance of electrolyte and paper mixture (other resistances not depending on the frequency are not considered: tabs, plates, etc.) C e = Electrolyte soaked paper capacitance L = Inductive reactance of the capacitor winding and terminals Impedance of an electrolytic capacitor is not a constant quantity that retains its value under all conditions; it changes depending on frequency and temperature. Impedance as a function of frequency (sinusoidal waveform) for a certain temperature can be represented as follows: C o R e L C e Z o h m F K H z B C A ω ω ω ω C o R e ω ω ω ω C e ω L
- Capacitive reactance predominates at low frequencies
- With increasing frequency, capacitive reactance Xc = 1/ωC o decreases until it reaches the order of magnitude of electrolyte resistance Re(A)
- At even higher frequencies, resistance of the electrolyte predominates: Z = R e (A - B)
- When the capacitor’s resonance frequency is reached (ω 0), capacitive and inductive reactance mutually cancel each other 1/ωCe = ωL, ω0 = C√1/LCe
- Above this frequency, inductive reactance of the winding and its terminals (XL = Z = ωL) becomes effective and leads to an increase in impedance Generally speaking, it can be estimated that C e ≈ 0.01 Co.
12© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Impedance (Z) cont’d Impedance as a function of frequency (sinusoidal waveform) for different temperature values can be represented as follows (typical values): Z o h m F K H z C C 10 µF C Re is the most temperature-dependent component of an electrolytic capacitor equivalent circuit. Electrolyte resistivity will decrease if temperature rises. In order to obtain a low impedance value throughout the temperature range, Re must be as little as possible. However, Re values that are too low indicate a very aggressive electrolyte, resulting in a shorter life of the electrolytic capacitor at high temperatures. A compromise must be reached. Leakage Current (LC) Due to the aluminum oxide layer that serves as a dielectric, a small current will continue to fl ow even after a DC voltage has been applied for long periods. This current is called leakage current. A high leakage current fl ows after applying voltage to the capacitor then decreases in a few minutes, e.g., after prolonged storage without any applied voltage. In the course of continuous operation, the leakage current will decrease and reach an almost constant value. After a voltage-free storage the oxide layer may deteriorate, especially at high temperature. Since there are no leakage currents to transport oxygen ions to the anode, the oxide layer is not regenerated. The result is that a higher than normal leakage current will fl ow when voltage is applied after prolonged storage.
13© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Leakage Current (LC) cont’d As the oxide layer is regenerated in use, the leakage current will gradually decrease to its normal level. The relationship between the leakage current and voltage applied at constant temperature can be shown schematically as follows: Where: V F = Forming voltage If this level is exceeded, a large quantity of heat and gas will be generated and the capacitor could be damaged. V R = Rated Voltage This level represents the top of the linear part of the curve. V S = Surge voltage This lies between VR and VF. The capacitor can be subjected to VS for short periods only. Electrolytic capacitors are subjected to a reforming process before acceptance testing. The purpose of this preconditioning is to ensure that the same initial conditions are maintained when comparing different products. Ripple Current (RC) The maximum ripple current value depends on:
- Ambient temperature
- Surface area of the capacitor (heat dissipation area) tan δ or ESR
- Frequency The capacitor’s life depends on the thermal stress. Frequency Dependence of the Ripple Current ESR and, thus, the tan δ depend on the frequency of the applied voltage. This indicates that the allowed ripple current is also a function of the frequency. Temperature Dependence of the Ripple Current The data sheet specifi es maximum ripple current at the upper category temperature for each capacitor. Expected Life Calculation Expected life depends on operating temperature according to the following formula: L = Lo x 2 (To-T)/10 Where: L: Expected life Lo: Load life at maximum permissible operating temperature T: Actual operating temperature To: Maximum permissible operating temperature This formula is applicable between 40°C and To. I VR VF VVS Actual Operating Temperature (C°) Expected Life Calculation Chart Expected life (h)
14© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Packaging Quantities Size Code Diameter (mm) Length (mm) Bulk Auto-insertion Standard Leads Cut Leads Ammo Tape & Reel H8 10 16 3000 4000 700 1200 H4 10 20 2400 3000 700 1200 L3 13 20 2000 2000 500 L4 13 25 1600 1600 500 M5 16 20 1000 500 300 M7 16 25 1000 500 300 M2 16 32 800 500 300 M3 16 36 600 500 300 N5 18 25 800 500 300 N1 18 32 500 500 N2 18 36 500 500 N9 18 50 500 500
15© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Marking Series, Rated Temperature KEMET Logo Polarity Stripe (−) Rated Capacitance Rated Voltage (VDC) Date Code Month*/Year* Manufacturing Internal Codes *Y = Year Code 01 02 03 04 05 06 07 08 09 Year 2011 2012 2013 2014 2015 2016 2017 2018 2019 *M = Month Code 01 02 03 04 05 06 07 08 09 10 11 12 Month 1 2 3 4 5 6 7 8 9 10 11 12 Construction Detailed Cross Section Margin Rubber SealLead Terminal Tab Aluminum Can Insulating Sleeve Lead (+) Polarity Stripe (−) Rubber Seal Insulating Sleeve Aluminum Can with Safety Vent Lead (−) Anode Aluminum Foil, Etched, Covered with Aluminum Oxide (Second Layer) Cathode Aluminum Foil, Etched (Fourth Layer) Paper Spacer Impregnated with Electrolyte (First Layer) Paper Spacer Impregnated with Electrolyte (Third Layer) Terminal Tabs Insulating End Disc
16© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Taping for Automatic Insertion Machines Dimensions (mm) D L p d P P0 P1 P2 W W0 W1 W2 H0 H1 I D0 t Formed to 2.5 mm Formed to 5 mm Straight leads 15-25 5 0.6 15 15 3.85 7.5 18 12 11 3 18.5 1 4 1 13 5 0.6 15 15 3.85 7.5 18 12 11 3 18.5 1 4 1 5 0.6 15 15 3.85 7.5 18 12 11 3 18.5 1 4 1 Formed to 2.5 mm (Lead and packaging code LA and FA) Formed to 5 mm (Lead and packaging code JA and DA) Straight Leads (Diameter: 4 – 8 mm) Lead and packaging code EA and KA Straight Leads (Diameter > 8) Lead and packaging code EA and KA A d h e s i v e t a p e p P H W W W W d P P P D M o u n t i n g t a p e D L H D M o u n t i n g t a p e A d h e s i v e t a p e H W W W d P P P L p D P W D M o u n t i n g t a p e A d h e s i v e t a p e p P H W L W W P P W D H D M o u n t i n g t a p e A d h e s i v e t a p e W H L W W d P P P W p D P I Maximum t Maximum t Maximum t Maximum t d P
17© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Lead Taping & Packaging H T W W H D Ammo Box Reel Case Size (mm) Ammo Reel H W T D H W Maximum Maximum ±2 ±0.5 +1/- 0.1 4 230 340 42 350 30 50 5 x 5 – 7 230 340 42 6.3 x 5 – 7 275 340 42 8 x 5 – 9 235 340 45 5 x 11 230 340 48 6.3 x 11 270 340 48 8 x 11 235 340 48 8 x 14 – 20 240 340 57 10 x 12 250 340 52 10 x 15 – 19 256 340 57 10 x 22 – 25 250 340 60 12 270 340 57 13 285 340 62 16 265 340 62
18© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC Extended cathode Anode foil Cathode foil Tissues Foil tabs Aging Etching Forming Winding Decking Impregnation Assembly Testing Sleeving Packing Construction Data The manufacturing process begins with the anode foil being electrochemically etched to increase the surface area and then “formed” to produce the aluminum oxide layer. Both the anode and cathode foils are then interleaved with absorbent paper and wound into a cylinder. During the winding process, aluminum tabs are attached to each foil to provide the electrical contact. The deck, complete with terminals, is attached to the tabs and then folded down to rest on top of the winding. The complete winding is impregnated with electrolyte before being housed in a suitable container, usually an aluminum can, and sealed. Throughout the process, all materials inside the housing must be maintained at the highest purity and be compatible with the electrolyte. Each capacitor is aged and tested before being sleeved and packed. The purpose of aging is to repair any damage in the oxide layer and thus reduce the leakage current to a very low level. Aging is normally carried out at the rated temperature of the capacitor and is accomplished by applying voltage to the device while carefully controlling the supply current. The process may take several hours to complete. Damage to the oxide layer can occur due to variety of reasons:
- Slitting of the anode foil after forming
- Attaching the tabs to the anode foil
- Minor mechanical damage caused during winding A sample from each batch is taken by the quality department after completion of the production process. This sample size is controlled by the use of recognized sampling tables defi ned in BS 6001. The following tests are applied and may be varied at the request of the customer. In this case the batch, or special procedure, will determine the course of action. Electrical:
- Leakage current
- Capacitance
- ESR
- Impedance
- Tan Delta Mechanical/Visual:
- Overall dimensions
- Torque test of mounting stud
- Print detail
- Box labels
- Packaging, including packed quantity
19© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com A40 64_ESU • 10/18/2016 Single-Ended Aluminum Electrolytic Capacitors – ESU Series, +105ºC KEMET Electronic Corporation Sales Offi ces For a complete list of our global sales offi ces, please visit www.kemet.com/sales. Disclaimer All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. KEMET is a registered trademark of KEMET Electronics Corporation.