4 Channels 1400W Energy Recycling DC Power Supply ERS-1400 s eri e s
File Name:ERS-1400 series-SPEC 2023-01-30 ‧Battery test or power supply aging system Front Panel (DC Input Side) Back Panel (DC Output Side) https://www.meanwell.com/serviceGTIN.aspx User’s Manual
SPECIFICATION (Note.1) PROTECTION OVER TEMPERATURE DC INPUT OVER VOLTAGE DC INPUT UNDER VOLTAGE OVER POWER ERS-1400 ERS-1400H Shuts down DC output voltage, reset after fault condition removed Shuts down DC output voltage, reset after fault condition removed Shuts down DC output voltage, reset after fault condition removed Shuts down AC output voltage after communication is failed for 4s. Reset after communication is re-built Constant power limiting at MAX input power 1200 ~ 1440W (for input 10 ~ 12VDC) 1440W (for input 12 ~ 60VDC) 864 ~ 1440W (for input 60 ~ 100VDC) 1440W (for input 100 ~ 380VDC) 10 ~ 60VDC 60 ~ 380VDC 30A*4CH 91% @ 48V input 3.6A*4CH 90% @ 380V input WORKING TEMP. PARALLEL WORKING HUMIDITY STORAGE TEMP.,HUMIDITY COOLING MTBF DIMENSION PACKING OTHERS -20 ~ +60℃ Please refer to function manual and user manual for more detail 20% ~ 90% RH non-condensing 85%@48VDC input/1440W (power supply efficiency≧95%) CONSTANT CURRENT (CC) : 0.5~3.6A(±1%) / per. channel CONSTANT VOLTAGE (CV) : 60~380VDC (±10V) ----- 85%@380VDC input/1440W (power supply efficiency≧96%) Internal fan cooling ERS-1400: 260.3K hrs min. Telcordia SR-332 (Bellcore) ; 29.4K hrs min. MIL-HDBK-217F (25℃) ERS-1400H: 264.2K hrs min. Telcordia SR-332 (Bellcore) ; 27.7K hrs min. MIL-HDBK-217F (25℃) 5.76Kg; 2pcs/12.5Kg/1.68CUFT ENVIRONMENT COMMUNICATION INTERFACE CC/CV/CP MODE SELECT (Note.2)FUNCTION CANBus, Baud Rate 250k bps (Maximum 64 units ERS-1400 series) CONSTANT CURRENT (CC) : 0.5~30A(±1%) / per. channel ----- CONSTANT POWER (CP) : 5~360W (±5%) / per. channel MODEL DC INPUT RATED INPUT POWER (Typ.) INPUT VOLTAGE RANGE RATED INPUT CURRENT (Typ.) EFFICIENCY (Typ.) COMMUNICATION ERROR
4 Channels 1400W Energy Recycling DC Power Supply ERS-1400 se rie s
File Name:ERS-1400 series-SPEC 2023-01-30 3.Guidance of additional filter, please refer to user manual for more detail. VOLTAGE VOLTAGE TOLERANCE RIPPLE & NOISE (max.) OUTPUT CURRENT (max.) DC OUTPUT 320VDC ±2% 6.3A VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INRUSH CURRENT (Typ.) AC INPUT 180 ~ 264VAC 47 ~ 63Hz 0.97/230VAC 50A /230VAC ENERGY RECYCLING RATIO (Typ.) Please refer to page 3 energy recycling ratio for more detail BS EN/EN62368-1 approvedSAFETY & EMC (Note. 4) SAFETY STANDARDS Compliance to BS EN/EN55032 (CISPR32) Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11 light industry level, criteria AEMC IMMUNITY Note.3 EMC EMISSION Note.3
70% 75% 80% 85% 90% 95% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 70% 75% 80% 85% 90% 95% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
4 Channels 1400W Energy Recycling DC Power Supply ERS-14 00 series
File Name:ERS-1400 series-SPEC 2023-01-30 LOAD EFFICIENCY ※ ERS-1400 model (1440W) (1440W) ※ ERS-1400H model Efficiencymeasured at 48VDC input and 25 of ambient temperature℃ Efficiencymeasured at 380VDC input and 25 of ambient temperature℃ EFFICIENCY vs LOAD Static Characteristics Energy Recycling Ratio Calculation INPUT VOLTAGE (VDC) INPUT VOLTAGE (VDC) 10 6012 8020 10025 13030 16035 19040 22045 25050 28055 31060 380 100 100 83.3 80 60 60 40 40 INPUT POWER (%) INPUT POWER (%) ※ ERS-1400 model ※ Energy recycling ratio = Efficiency 1 (power supply) x Efficiency 2 (ERS-1400 series) ※ ERS-1400H model Block Diagram
4 CHANNELS
(Up to 4 EUTs max.) AC/DC CONVERTER 1 AC/DC CONVERTER 2 AC/DC CONVERTER 3 AC/DC CONVERTER 4 (INDEPENDENT or PARALLEL USED) CH1 DC/DC AC/DC ERS-1400 series DC ENERGY RECYCLE CH2 DC/DC CH3 DC/DC CH4 DC/DC RECTIFIERS RECTIFIERS RECTIFIERS RECTIFIERS & DATA ISOLATION CMU2A (CONTROL CONSOLE) or CANBus INTERFACE DC(320V) AC UTILITY FILTER FILTER FILTER FILTER LOAD (1400W) EFFICIENCY (1400W)
2020 34.25
15 V1V2V3
Mechanical Specification Case No. ERS-1400 Unit:mm ◎ERS-1400 series File Name:ERS-1400 series-SPEC 2023-01-30 Pin No. Pin No. ※ Pin No. Assignment :Communication port ※Address setting Pin No. Assignment : ※ DC OUTPUT Pin No. Assignment : ※ V1~V4 LED Status Indicators ※ DC Input Pin No. Assignment : PRO-TEN 5.7mm NEWSOK PCB mount assembly or equivalent 1 1 2 Function Function Function Description CANH ON HV+ 320Vdc + HV- 320Vdc - 18Kgf-cm FG NC NC CANL OFF
Description
Diagram Maximum mounting torque Data line used in CANBus interface ERS-1400 DC input voltage in series (for CH1 PIN 1&2,CH2 PIN 3&4, CH3 PIN 5&6, CH4 PIN 7&8) Data line used in CANBus interface Retain for future use ERS-1400 DC input voltage in dependent (for CH1 PIN 9&10,CH2 PIN 11&12, CH3 PIN 13&14, CH4 PIN 15&16) Reference ground for CANBus interface Not use Pin No. 1,3,5,7,9, 11,13,15 2,4,6,8, 10,12,14,16 Function Description Mating Housing Positive end of DC input CH1: PIN1 & 9, CH2: PIN3 & 11, CH3: PIN5 & 13, CH4: PIN7 & 15 Negative end of DC input CH1: PIN2 & 10, CH2: PIN4 & 12, CH3: PIN6 & 14, CH4: PIN8 & 16 PRO-TEN 5.7mm NEWSOK SURLOK PIN or equivalent PRO-TEN 5.7mm NEWSOK SURLOK PIN or equivalent LED OFF LED Steady Green Flashing Green No AC utility connected 16-ψ12 Communication port 1 9 8 16 ON 1 2 3 4 5 6AC INPUT Address setting DC OUTPUT 320Vdc Air flow direction 15max. 30.820202020 22.6 168 CH1 CH2 CH4 DC INPUT AC INPUT 63.5 213 450 8.6 ※ Address setting For CANBus interface address setting, please refer to the user manual for more details 40 11.75 12-M4 L=6(Both Sides) 12.538 310 439.5 1,9 4,12 3,11 2,10 5,6,7,8,13 14,15,16
- Energy Recycle Burn-in System Diagram Power Supply(1 ~ 4 EUTs) ERS-1400 series CMU2A or CANBus Interface Power Input (Energy Recycle) AC Input AC Input Communication Interface Ethernet 2.Front Panel Connection Diagram (1)SW1 turn OFF (2)SW1 turn ON ,(Increase burn-in power confiquration) AC/L AC/L Power Supply Power Supply (Power >1440W) AC/N AC/N FG FG CMU2A System Parm. Status Log Set Info !Home CC Standby Status OTP FAN A0.5 0 TOUCH TO STOP STEP1 ERS-1400 series ERS-1400 series x N
4 Channels DC Input
(Parallel or standalone use) Note : Select suitable wires for connection between the power supply(EUTs) and the ERS-1400 series to reduce line loss and increase energy recycling ratio. File Name:ERS-1400 series-SPEC 2023-01-30 ON ON OFF OFF (320Vdc) 320Vdc 320Vdc
Parm. Status Log Set Info !Home CC Standby Status OTP FAN A0.5 0 TOUCH TO STOP STEP1 RS-485RS-232PMBusCANBus CANBusEthernet EthernetSlot 1 9 11 16 88 Slot 2Slot 3 FGLN 1 2 9 911 1 116 1688 8 6 Energy Recycle AC Inlet 3.Back Panel Connection Diagram L FG N AC Utility 180 ~ 264 5VAC± ERS-1400 series Note : After connecting the communication cable, install termination resistors to the remaining sockets of both the ERS-1400 series and CMU2A to prevent signal reflections. Communication Cable(Twisted pair) Termination resistor Termination resistor CMU2A (Front Panel) CMU2A (Back Panel) 90~264VAC
4 Channels 1400W Energy Recycling DC Power Supply ERS- 1400 se rie s
File Name:ERS-1400 series-SPEC 2023-01-30 (3)SW1 turn ON ,(Increase burn-in voltage confiquration) AC/L AC/L AC/L AC/L Power Supply 4 (Vo<10V) Power Supply 3 (Vo<10V) Power Supply 2 (Vo<10V) Power Supply 1 (Vo<10V) Vo 4 Vo 3 Vo 2 Vo 1 AC/N AC/N AC/N AC/N FG FG FG FG ERS-1400 series (Input: Vo1 +Vo2 +Vo3 +Vo4) ON OFF 320Vdc 320Vdc 320Vdc 320Vdc
Black wire for -V connector UL1028 8AWG UL1028 8AWG 500 500 Quantity File Name:ERS-1400 series-SPEC 2023-01-30 Termination resistor