EPP-300 MEANWELL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
300W Single Output with PFC Function E P P = 3 0 0 series el @ Features : * Universal AC input / Full range <>. * Built-in active PFC function ZN * Wistand 300VAC surge input for 5 seconds
2 Fah ZS ‘ONS * Protections: Short circuit / Overload / Over voltage / Over temperature
“ ‘ > Dew * Built-in 12V/0.5A auxiliary output (e e< Pe * 5°x3" compact size e {.) * Free air convection for 200W and 300W with 20.5 CFM forced air Ss i * With power good and fail signal output : } ar * Built-in remote sense function ge” * No load power consumption under 0.5W by PS-ON control y * Standby 5V@1A with fan @ 0.6A without fan * 3 years warranty SPECIFICATION ® WM. %= | CBCE [RATED CURRENT (20.5CFM) [254 204 RATED POWER (convection) | 200” oureut 30% 420% 20% 10% 10% 2500ms, 30ms/230VAC __3000ms, 30ms/115VAC at full load 90~264VAC_ 127 ~370VDC 47-6342 input a OVER VOLTAGE PROTECTION Protection type : Shut down o/p voltage, re-power on to recover CENETEMUE aweron exo EMC UP-OIP, lIP-FG, OIP-FG:100M Ohms / S00VDC / 25°C70% RH ee PACKING | O87 Kai S6pes/t4akgit.03CUFT, 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°Gof ambient temperature NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. ~ 4, The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets. EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” {as available on http:/www.meanwell.com), 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Heat Sink HS1,HS2 can not be shorted. File Name:EPP-300-SPEC 2072-07-12
MEAN WELL} 300W Single Output with PFC Function E P P = 3 0 0 series Ce en el
1 Mechanical Specification Unit:mm
w AC Input Connector (CN1) : JST B5P-VH or equivalent 2 Pin No. Mating Housing Terminal er 7 + 1 to 42 24 | NoPin | JsTVHR = JSTSVH-21T-P1.1 7 TW? 3 orequivalent |” orequivalent —— CS 1_| 5 —d ) N a] onose EES cnet = & tel D DC Output Connector (CN2,CN3) = : oO ST et [PinNo. | Assignment | Output Terminals wa [East HS2 i CN2_|_-V__|M4Pan HD screw in2 positions e@) 8) tyr na H0 [Se CN3_| _#V__| Torque to 8lbs-in(90cNmn)max. i 0 J [ ) 2 ea (EE) Function Connector(CN100):JST $48-PHDSS or equivalent ae) © |oo0 Pin No Mating Housing | Terminal 4 [ al, 2 JSTPHDR-8VS | JST SPHD-001T-PO5 = “Ge 3_| DCCOM | orequivalent | orequivalent lo Airfl “os SD dtecion ° 4 PG 20.5CFM Function Connector(CN951):JST $4B-PHDSS or equivalent PinNo.| Status | MatingHousing | Terminal al = 1 ba JSTPHDR-8VS JST SPHD-OOTT-POS or equivalent or equivalent 8 3 fy } FAN Connector(CN952) : JST S2B-XH or equivalent z _fm! I [| Terminal s . 1 oc com JSTXHP | JST SXH-001T-PO6 AY H81,HS2 can not be shorted 2 12V orequivalent | or equivalent @ Block Diagram +5VSB PFC fosc : 6SKHz DETECTION PWM fosc : TOKHz CIRCUIT “POWERSWITCHING | =| € | RECTIFIERS +588 PWM CONTROL SEL Futer E RECTIERS | _, stavaux © |_ FILTER 048 i EMI RECTIFIERS power | 3 ¢ [RECTIFIERS too FILTER pic SWITCHING [357 eufeR rev PG © PG BS OLP.--| CONTROL eles Taher a © Ove © PSION o PS ee BPO PS-ON @ Derating Curve 1 Output Derating VS Input Voltage 300) 7 00 With 20.5CFM Fan co 20 4 ao 150 ‘*15VAC aN 1 0 = 230VAC Convection =e = 100 4 z 2 a 4 =z 0 gS 2 20) 40D «BD 70.(HORIZONTAL) 90 9 100 115 120 140 160 180 200 220 240 266 AMBIENT TEMPERATURE ('C) INPUT VOLTAGE (VAC) 60Hz File Name:EPP-300-SPEC 2012-07-12