The Cooper Bussmann® Coordination Module™ All-In-One Solution Saves You Time & Money

  • Meets Code Requirements Helps comply with the NEC® Selective Coordination Requirements for Emergency, Legally Required Standby, Healthcare, Essential Electrical and Critical Operation Power Per the NEC ® : Coordination (Selective) is the localization of an overcurrent condition to restrict outages to the circuit or equipment affected, accomplished by the choice of overcurrent protective devices and their ratings or settings.
  • Increases Safety The objective of the selective coordination requirements is to ensure system uptime with the goal of safety of human life during emergencies, or for essential health care functions. The Coordination Module™ meets this objective by providing reliable current-limiting operation to minimize the effects of an outage to the smallest portion of the system as possible.
  • Saves Time The Coordination Module provides a fast and easy solution to meeting selective coordination Code requirements. Simply utilize published fuse selective coordination ratios to select the correct upstream fuse ratings. In addition, locate open fuses fast with the easyID™ neon indicator.
  • Saves Money Offers significant savings compared to other fused panels and selectively coordinated circuit breaker systems. Meeting The New Selective Coordination Code Requirements Is Easy

Coordination Module™ Specifications Voltage Short-Circuit Dimensions – in Branch Circuit Number of Series Rating Current Rating Amp Rating Circuits EP2M23012GCC 120/208V 100kA* 28 36 5.75 30 12 EP2M23024GCC 120/208V 100kA* 28 36 5.75 30 24 EP2M23036GCC 120/208V 100kA* 28 48 5.75 30 36 EP2M23042GCC 120/208V 100kA* 28 48 5.75 30 42 EP3M23012GCC 120/240V 100kA* 28 36 5.75 30 12 EP3M23024GCC 120/240V 100kA* 28 36 5.75 30 24 EP3M23036GCC 120/240V 100kA* 28 48 5.75 30 36 EP3M23042GCC 120/240V 100kA* 28 48 5.75 30 42 EP4M23012GCC 277/480V 100kA 28 36 5.75 30 12 EP4M23024GCC 277/480V 100kA 28 36 5.75 30 24 EP4M23036GCC 277/480V 100kA 28 48 5.75 30 36 EP4M23042GCC 277/480V 100kA 28 48 5.75 30 42 * When protected by upstream LPN-RK 100A max, LPJ 200A max or JJN 200A max, otherwise 10kA. ** When protected by upstream LPS-RK 200A max, LPJ 200A max or JJS 200A max, otherwise 14kA. Main breaker option may impact selective coordination. Coordination must be verified analyzing time current curves and availabl e current. Coordination Module™ Catalog Numbering System Prefix General Purpose Enclosure Type of Branch Circuit Fuses EP = Emergency Panel Main Number of Circuits Branch Circuit Amperage Main Amperage (200 Amps Max) Voltage 2 = 120/208V 3P , 4W 3 = 120/240V 1P , 3W 4 = 277/480V 3P , 4W Example: 1 = 100A 1.5 = 150A 2 = 200A 30A Max TYPE 1 only CC Fuses M = MLO *B =Breaker EP 2 M 2 30 42 G CC NEMA Type 1 enclosure with surface mount trim. Ground Bar bolted with set screw terminations. 120/208V or 277/480V Main lugs with AWG 6-300Kcmil terminations. Full-Sized neutral bar with set-screw terminations. Class CC fuse holders with easyID™ neon indicator Provides ease of coordination with superior overcurrent protection and open fuse indication. 12 to 42 Circuits. Branch circuit breakers provide circuit isolation. 200A Copper main bus. Feed-through lugs available upon request. See data sheet 1149 for more information. Additional main configurations available, see data sheet 1149 for more information. ©2008 Cooper Bussmann St. Louis, MO 63178 636-394-2877 www.cooperbussmann.com Reorder # 3115 10-08-5M Printed in USA WH D 1 6 5 5 *Main breaker drops assembly SCCR to 10kA.