Technical content

EE06v2.2 Measuring values Relative humidity Sensor HC101 model B 0...95% RH Accuracy at 20°C (68°F), 12V DC ±3% RH (0...95% RH) Temperature dependence model F/FT d RH = -0.00035 x RH x (T-20°C) model FP d RH = typ. (-0.003 x RH + 0.01) x (T-20°C) Temperature (active output) Sensor Pt1000 (class A, DIN EN 60751) Accuracy at 12V DC Temperature (passive output) Type of T-Sensor please see ordering guide General Supply voltage 4.5V DC - 30V DC Current consumption typ. 1.5 mA Housing Polycarbonat / IP65 (Model A) in vertical mounting (filter cap upside) Sensor protection membrane filter, plastic grid, metal grid filter Electromagnetic compatibility EN 61000-6-3 EN 61000-6-1 FCC Part15 ClassB ICES-003 ClassB Small Size Transmitter for Humidity and Temperature EE06 series are compact transmitters for humidity, and combined humidity/temperature measurement with excellent price / performance ratio. They are optimised for OEM applications and available with or without housing. With appropriate filter cap EE06 can operate successfully even in harsh environments. The analogue output for both humidity and temperature is 0-1 V. The temperature output signal can be active or passive. The very small dimensions, low energy consumption and supply voltages down to 4.5 V allow cost-effective and easy positioning of the transmitters. humidifiers and dehumidifiers climate controls in museums, hotels monitoring of storage rooms photostatic machines control meteorological applications very small dimensions excellent price-performance-ratio long term stability easy installation low energy consumption EE06 SeriesEE06 Series TTypicalypical AApplicapplica tionstions FFeaeaturtur eses TTecechnical Dahnical Da tata ∆°Χ EE06

MODEL OUTPUT T-SENSOR TYPE FILTER CABLE LENGTH (only passive) (Type A + C) humidity and temperature (FT) 0 - 1 V (1) Pt 100 DIN A (A) with housing (A) membrane filter (1) 0.5m (1.6ft) (no code) humidity (F) Pt 100 DIN B (B) without housing (B) plastic grid (4) 1.5m (4.9ft) (K150) humidity and temperature passive(FP) Pt 1000 DIN A (C) with thread (C) metal grid filter (6) 3m (9.8ft) (K300) Pt 1000 DIN B (D) 5m (16.4ft) (K500) NTC 10K at 25°C (E) 10m (32.8ft) (K1000) Ø12 Ø12 34 Ø12 M10x1 EE06- EE06-FT1A1-K300 model: humidity and temperature output: 0-1 V housing: with housing filter: membrane filter cable length 3m (9.8ft) VV power supply 4.5...30V DC +V (white) GND (brown) RH (green) T (yellow) Housing dimensions (mm)Housing dimensions (mm) Connection DiaConnection Dia ggrramam OrOr dering Guidedering Guide Type A Type B Type C cable length standard = 500mm (19.7”) cable length standard = 500mm (19.7”) cable length standard = 200mm (7.9”) OrOr derder ExampleExample V power supply 4.5...30V DC +V (white) GND (brown) RH (green) /c87 Tpassive2 (gray) Tpassive1 (yellow) 1 mm = 0.03937” / 1” = 25.4 mm - radiation shield (for more information please refer to data sheet “Accessories”) (HA010502) AccessoriesAccessories